Shintaro Nakatani

Dr. Shintaro Nakatani

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MKMasaya Kimura
Masaya Kimura
SNShintaro Nakatani
Shintaro Nakatani
SNShin-Ichiro Nishida
Shin-Ichiro Nishida
DTDaiju Taketoshi
Daiju Taketoshi
NANozomu Araki
Nozomu Araki
Various dry electroencephalography (EEG) electrodes have been developed. Dry EEG electrodes need to be pressed onto the scalp; therefore, there is a tradeoff between keeping the contact impedance low and maintaining comfort. We propose an approach to solve this tradeoff through the printing of complex-shaped electrodes by using a stereolithography 3D printer. To show the feasibility of our approach, we fabricated electrodes that have flexible fingers (prongs) with springs. Although dry electrodes with flexible prongs have been proposed, a suitable spring constant has not been obtained. In this study, the spring constant of our electrodes was determined from a contact model between the electrodes and the scalp. The mechanical properties and reproductivity of the electrodes were found to be sufficient. Finally, we measured the alpha waves when a participant opened/closed his eyes by using our electrodes.



1 February 2021 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
SNShintaro Nakatani
Shintaro Nakatani
NANozomu Araki
Nozomu Araki
THTakayuki Hoshino
Takayuki Hoshino
OFOsamu Fukayama
Osamu Fukayama
KMKunihiko Mabuchi
Kunihiko Mabuchi
Objective. Robotic rehabilitation systems have been investigated to assist with motor dysfunction recovery in patients with lower-extremity paralysis caused by central nervous system lesions. These systems are intended to provide appropriate sensory feedback associated with locomotion. Appropriate feedback is thought to cause synchronous neuron firing, resulting in the recovery of function. Approach. In this study, we designed and evaluated an ergometric cycling wheelchair, with a brain–machine interface (BMI), that can force the legs to move by including normal stepping speeds and quick responses. Experiments were conducted in five healthy subjects and one patient with spinal cord injury (SCI), who experienced the complete paralysis of the lower limbs. Event-related desynchronization in the β band (18–28 Hz) was used to detect lower-limb motor images. Main results. An ergometer-based BMI system was able to safely and easily force patients to perform leg movements, at a rate of approximately 1.6 s/step (19 rpm), with an online accuracy rate of 73.1% for the SCI participant. Mean detection time from the cue to pedaling onset was 0.83 ± 0.31 s. Significance. This system can easily and safely maintain a normal walking speed during the experiment and be designed to accommodate the expected delay between the intentional onset and physical movement, to achieve rehabilitation effects for each participant. Similar BMI systems, implemented with rehabilitation systems, may be applicable to a wide range of patients.

8 September 2018 in J. of Electrical Engineering
Verified
Journal Article
Open access
SNShin-Ichiro Nishida
Shin-Ichiro Nishida
DUDaisuke Uenaka
Daisuke Uenaka
RMRyota Matsumoto
Ryota Matsumoto
SNShintaro Nakatani
Shintaro Nakatani

19 December 2023 in Journal of Terramechanics
Verified
Journal Article
Closed access
AOAsahi Oe
Asahi Oe
SNShin-Ichiro Nishida
Shin-Ichiro Nishida
SNShintaro Nakatani
Shintaro Nakatani