Estela Climent

Estela Climent

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
Estela ClimentEstela Climent
Estela Climent
KRKnut Rurack
Knut Rurack
The combination of electrogenerated chemiluminescence (ECL) and aptamer‐gated indicator delivering (gAID) magnetic mesoporous silica nanoparticles embedded into glass fibre paper functionalised with poly(ethyleneglycol) andN‐(3‐triethoxysilylpropyl)diethanolamine allowed the development of a rapid test that detects penicillin directly in diluted milk down to 50±9 ppt in <5 min. Covalent attachment of the aptamer “cap” to the silica scaffold enabled pore closure through non‐covalent electrostatic interactions with surface amino groups, while binding of penicillin led to a folding‐up of the aptamer thus releasing the ECL reporter Ru(bpy)32+previously loaded into the material and letting it be detected after lateral flow by a smartphone camera upon electrochemical excitation with a screen printed electrode inserted into a 3D‐printed holder. The approach is simple, generic and presents advantages with respect to sensitivity, measurement uncertainty and robustness compared with conventional fluorescence or electrochemical detection, especially for point‐of‐need analyses of challenging matrices and analytes at ultra‐trace levels.

7 September 2020 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
Estela ClimentEstela Climent
Estela Climent
MBMustafa Biyikal
Mustafa Biyikal
DGDelia Gröninger
Delia Gröninger
Michael G. WellerMichael G. Weller
Michael G. Weller
RMRamón Martínez-Máñez
Ramón Martínez-Máñez
KRKnut Rurack
Knut Rurack
Rapid testing methods for the use directly at a point of need are expected to unfold their true potential especially when offering adequate capabilities for the simultaneous measurement of multiple analytes of interest. Considering the unique modularity, high sensitivity, and selectivity of antibody‐gated indicator delivery (gAID) systems, a multiplexed assay for three small‐molecule explosives (TATP, TNT, PETN) was thus developed, allowing to detect the analytes simultaneously with a single test strip at lower ppb concentrations in the liquid phase in <5 min using a fluorescence reader or a smartphone for readout. While the TNT and PETN systems were newly developed here, all the three systems also tolerated harsher matrices than buffered aqueous model solutions. Besides a single‐track strip, the outstanding modularity of the hybrid biosensor materials in combination with strip‐patterning technologies allowed us to obtain a multichannel strip in a straightforward manner, offering comparable analytical performance while allowing to be tailored even more to the user's need.

6 April 2020 in The Analyst
Verified
Journal Article
Closed access
PDF file
ECElena Costa
Elena Costa
Estela ClimentEstela Climent
Estela Climent
SASandra Ast
Sandra Ast
Michael G. WellerMichael G. Weller
Michael G. Weller
JCJohn Canning
John Canning
KRKnut Rurack
Knut Rurack
The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use.

21 December 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
CTCharlie Tobias
Charlie Tobias
Estela ClimentEstela Climent
Estela Climent
KGKornelia Gawlitza
Kornelia Gawlitza
KRKnut Rurack
Knut Rurack
Functional core/shell particles are highly sought after in analytical chemistry, especially in methods suitable for single-particle analysis such as flow cytometry because they allow for facile multiplexed detection of several analytes in a single run. Aiming to develop a powerful bead platform of which the core particle can be doped in a straightforward manner while the shell offers the highest possible sensitivity when functionalized with (bio)chemical binders, polystyrene particles were coated with different kinds of mesoporous silica shells in a convergent growth approach. Mesoporous shells allow us to obtain distinctly higher surface areas in comparison with conventional nonporous shells. While assessing the potential of narrow- as well as wide-pore silicas such as Mobil composition of matter no. 41 (MCM-41) and Santa Barbara amorphous material no. 15 (SBA-15), especially the synthesis of the latter shells that are much more suitable for biomolecule anchoring was optimized by altering the pH and both, the amount and type of the mediator salt. Our studies showed that the best performing material resulted from a synthesis using neutral conditions and MgSO4 as an ionic mediator. The analytical potential of the particles was investigated in flow cytometric DNA assays after their respective functionalization for individual and multiplexed detection of short oligonucleotide strands. These experiments revealed that a two-step modification of the silica surface with amino silane and succinic anhydride prior to coupling of an amino-terminated capture DNA (c-DNA) strand is superior to coupling carboxylic acid-terminated c-DNA to aminated core/shell particles, yielding limits of detection (LOD) down to 5 pM for a hybridization assay, using labeled complementary single-stranded target DNA (t-DNA) 15mers. The potential of the use of the particles in multiplexed analysis was shown with the aid of dye-doped core particles carrying a respective SBA-15 shell. Characteristic genomic sequences of human papillomaviruses (HPV) were chosen as the t-DNA analytes here, since their high relevance as carcinogens and the high number of different pathogens is a relevant model case. The title particles showed a promising performance and allowed us to unequivocally detect the different high- and low-risk HPV types in a single experimental run.

17 January 2022 in Advanced Engineering Materials
Verified
Journal Article
Open access
PDF file
DHDeniz Hülagü
Deniz Hülagü
CTCharlie Tobias
Charlie Tobias
Estela ClimentEstela Climent
Estela Climent
AGArdian Gojani
Ardian Gojani
KRKnut Rurack
Knut Rurack
VHVasile-Dan Hodoroaba
Vasile-Dan Hodoroaba
The roughness as a property of core-shell (CS) microparticles plays a key role in their functionality. Quantitative evaluation of the roughness of CS microparticles is however a challenging task with approaches using electron microscopy images being scarce and showing pronounced differences in terms of methodology and results. This work presents a generalized method for the reliable roughness determination of nonplanar specimens such as CS particles from electron microscopic images, the method being robust and reproducible with a high accuracy. It involves a self-written software package (Python) that analyzes the recorded images, extracts corresponding data, and calculates the roughness based on the deviation of the identified contour. Images of single particles are taken by a dual mode Scanning Electron Microscopy (SEM) set-up which permits imaging of the same field-of-view of the sample with high-resolution and surface sensitive in SE InLens® mode as well as in transmission mode (TSEM). A new type of polystyrene core-iron oxide shell-silica shell particles was developed here to serve as a set of lower micron-sized study objects with different surface roughness, the analysis of their images by the semi-automatic workflow demonstrating that the particles’ profile roughness can be quantitatively obtained.

8 September 2022 in Nanoscale
Verified
Journal Article
Closed access
PDF file
Eva Garrido GarcíaEva Garrido García
Eva Garrido García
Estela ClimentEstela Climent
Estela Climent
MMM. Dolores Marcos
M. Dolores Marcos
FSFélix Sancenón
Félix Sancenón
KRKnut Rurack
Knut Rurack
RMRamón Martínez-Máñez
Ramón Martínez-Máñez
We report herein the design of a strip-based rapid test utilizing bio-inspired hybrid nanomaterials for the in situ and at site detection of the drug scopolamine (SCP) using a smartphone for readout, allowing SCP identification in diluted saliva down to 40 nM in less than 15 min. For this purpose, we prepared a nanosensor based on mesoporous silica nanoparticles loaded with a fluorescent reporter (rhodamine B) and functionalized with bethanechol, a potent agonist of recombinant human muscarinic acetylcholine receptor M2 (M2-AChR). M2-AChR interaction with the anchored bethanechol derivative leads to capping of the pores. The sensing mechanism relies on binding of SCP to M2-AChR resulting in pore opening and delivery of the entrapped rhodamine B reporter. Moreover, the material was incorporated into strips for lateral-flow assays coupled to smartphone readout, giving fast response time, good selectivity, and exceptional sensitivity. In an attempt to a mobile analytical test system for law enforcement services, we have also developed a dualplex lateral flow assay for SCP and 3,4-methylenedioxypyrovalerone (MDPV) also known as the so-called “cannibal drug”.