Thomas Schultz

Prof. Dr. Thomas Schultz

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2014
Verified
Book Chapter
Closed access
PDF file
GBGeorges-Pierre Bonneau
Georges-Pierre Bonneau
HHHans-Christian Hege
Hans-Christian Hege
CJChris R. Johnson
Chris R. Johnson
MOManuel M. Oliveira
Manuel M. Oliveira
KPKristin Potter
Kristin Potter
TSThomas Schultz
Thomas Schultz

22 August 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
Sobhan MoazemiSobhan Moazemi
Sobhan Moazemi
ZKZain Khurshid
Zain Khurshid
AEAnnette Erle
Annette Erle
SLSusanne Lütje
Susanne Lütje
MEMarkus Essler
Markus Essler
Ralph Alexander BundschuhRalph Alexander Bundschuh
Ralph Alexander Bundschuh
Gallium-68 prostate-specific membrane antigen positron emission tomography (68Ga-PSMA-PET) is a highly sensitive method to detect prostate cancer (PC) metastases. Visual discrimination between malignant and physiologic/unspecific tracer accumulation by a nuclear medicine (NM) specialist is essential for image interpretation. In the future, automated machine learning (ML)-based tools will assist physicians in image analysis. The aim of this work was to develop a tool for analysis of 68Ga-PSMA-PET images and to compare its efficacy to that of human readers. Five different ML methods were compared and tested on multiple positron emission tomography/computed tomography (PET/CT) data-sets. Forty textural features extracted from both PET- and low-dose CT data were analyzed. In total, 2419 hotspots from 72 patients were included. Comparing results from human readers to those of ML-based analyses, up to 98% area under the curve (AUC), 94% sensitivity (SE), and 89% specificity (SP) were achieved. Interestingly, textural features assessed in native low-dose CT increased the accuracy significantly. Thus, ML based on 68Ga-PSMA-PET/CT radiomics features can classify hotspots with high precision, comparable to that of experienced NM physicians. Additionally, the superiority of multimodal ML-based analysis considering all PET and low-dose CT features was shown. Morphological features seemed to be of special additional importance even though they were extracted from native low-dose CTs.

1 December 2019 in Ophthalmology Retina
Verified
Journal Article
Closed access
ZWZhichao Wu
Zhichao Wu
CLChi D. Luu
Chi D. Luu
LHLauren A.B. Hodgson
Lauren A.B. Hodgson
ECEmily Caruso
Emily Caruso
KBKate H. Brassington
Kate H. Brassington
RGRobyn H. Guymer
Robyn H. Guymer

1 November 2020 in Software Impacts
Verified
Journal Article
Open access
CWChristian Winkler
Christian Winkler
KLKatharina Linden
Katharina Linden
AMAndreas Mayr
Andreas Mayr
TSThomas Schultz
Thomas Schultz
TWThomas Welchowski
Thomas Welchowski
UHUlrike Herberg
Ulrike Herberg

29 July 2021 in Tomography
Verified
Journal Article
Open access
PDF file
AEAnnette Erle
Annette Erle
Sobhan MoazemiSobhan Moazemi
Sobhan Moazemi
SLSusanne Lütje
Susanne Lütje
MEMarkus Essler
Markus Essler
TSThomas Schultz
Thomas Schultz
Ralph Alexander BundschuhRalph Alexander Bundschuh
Ralph Alexander Bundschuh
The importance of machine learning (ML) in the clinical environment increases constantly. Differentiation of pathological from physiological tracer-uptake in positron emission tomography/computed tomography (PET/CT) images is considered time-consuming and attention intensive, hence crucial for diagnosis and treatment planning. This study aimed at comparing and validating supervised ML algorithms to classify pathological uptake in prostate cancer (PC) patients based on prostate-specific membrane antigen (PSMA)-PET/CT. Retrospective analysis of 68Ga-PSMA-PET/CTs of 72 PC patients resulted in a total of 77 radiomics features from 2452 manually delineated hotspots for training and labeled pathological (1629) or physiological (823) as ground truth (GT). As the held-out test dataset, 331 hotspots (path.:128, phys.: 203) were delineated in 15 other patients. Three ML classifiers were trained and ranked to assess classification performance. As a result, a high overall average performance (area under the curve (AUC) of 0.98) was achieved, especially to detect pathological uptake (0.97 mean sensitivity). However, there is still room for improvement to detect physiological uptake (0.82 mean specificity), especially for glands. The ML algorithm applied to manually delineated lesions predicts hotspot labels with high accuracy on unseen data and may be an important tool to assist in clinical diagnosis.

26 January 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SMSimon Mueller
Simon Mueller
MWMaximilian W. M. Wintergerst
Maximilian W. M. Wintergerst
PFPeyman Falahat
Peyman Falahat
FHFrank G. Holz
Frank G. Holz
CSChristian Schaefer
Christian Schaefer
TSThomas Schultz
Thomas Schultz
Peripheral arterial disease (PAD) is caused by atherosclerosis and is a common disease of the elderly leading to excess morbidity and mortality. Early PAD diagnosis is important, as the only available causal therapy is addressing risk factors like smoking, hypercholesterolemia or hypertension. However, current diagnostic techniques often do not detect early stages of PAD. We theorize that PAD’s underlying cause atherosclerosis can be detected on color fundus photography (CFP) images with a convolutional neural network architecture, which might aid earlier PAD diagnosis and improve disease monitoring. In this explorative study a deep attention-based Multiple Instance Learning (MIL) architecture is used to capture retinal imaging biomarkers on CFP images of 135 examinations. To capture subtle variations in vascular structures, higher image resolution can be utilized by partitioning the CFP into patches. Our architecture converts each patch into a feature vector, and determines its relative importance via an automatically computed attention weight. Our best model achieves an ROC AUC score of 0.890. Visualizing these attention weights provides insights about the network’s decision and suggests ocular involvement in PAD. Statistical analysis confirms that the optic disc and the temporal arcades are weighted significantly higher (p < 0.001) than retinal background. Our results support the feasibility of detecting the presence of PAD with a modern deep learning approach.