1 November 2020 in Software Impacts
1 August 2020 in Computers in Biology and Medicine
Left ventricular stroke work is an important prognostic marker to analyze cardiac function. Standard values for children are, however, missing. For clinicians, standards can help to improve the treatment decision of heart failures. For engineers, they can help to optimize medical devices. In this study, we estimated the left ventricular stroke work for children based on modeled pressure-volume loops. A lumped parameter model was fitted to clinical data of 340 healthy children. Reference curves for standard values were created over age, weight, and height. Left ventricular volume was measured with 3D echocardiography, while maximal ventricular pressure was approximated with a regression model from the literature. For validation of this method, we used 18 measurements acquired by a conductance catheter in 11 patients. The method demonstrated a low absolute mean difference of 0.033 J (SD: 0.031 J) for stroke work between measurement and estimation, while the percentage error was 21.66 %. According to the resulting reference curves, left ventricular stroke work of newborns has a median of 0.06 J and increases to 1.15 J at the age of 18 years. Stroke work increases over weight and height in a similar trend. The percentile curves depict the distribution. We demonstrate how reference curves can be used for quantification of differences and comparison in patients.
1 February 2021 in PLOS ONE
Objectives: The gold standard to obtain pressure-volume relations (PVR) of the heart, the conductance technology (PVRCond), is rarely used in children. PVR can also be obtained by 3D-echocardiography volume data combined with simultaneously measured pressure data by a mini pressure-wire (PVR3DE). We sought to investigate the feasibility of both methods in patients with univentricular hearts and to compare them, including hemodynamic changes. Methods: We studied 19 patients (age 2–29 years). PVR3DE and PVRCond were assessed under baseline conditions and stimulation with dobutamine. Results: Obtaining PVR3DE was successful in all patients. Obtaining PVRCond was possible in 15 patients during baseline (79%) and in 12 patients under dobutamine (63%). Both methods showed that end-systolic elastance (Ees) and arterial elastance (Ea) increased under dobutamine and that Tau showed a statistically significant decrease. Intraclass correlation (95% confidence interval) showed moderate to good agreement between methods: Ees: 0.873 (0.711–0.945), Ea: 0.709 (0.336–0.873), Tau: 0.867 (0.697–0.942). Bland-Altman analyses showed an acceptable bias with wider limits of agreement: Ees: 1.63 mmHg/ml (-3.83–7.08 mmHg/ml), Ea: 0.53 mmHg/ml (-5.23–6.28 mmHg/ml), Tau: -0,76 ms (-10.73–9.21 ms). Conclusion: Changes of PVR-specific parameters under dobutamine stimulation were reflected in the same way by both methods. However, the absolute values for these parameters could vary between methods and, therefore, methods are not interchangeable. Obtaining PVR3DE in a single ventricle was easier, faster and more successful than PVRCond. PVR3DE provides a promising and needed alternative to the conductance technology for the assessment of cardiac function in univentricular hearts.
16 July 2018 in Journal of the American Society of Echocardiography