Danijela Nikolić

Prof. Danijela Nikolić

Faculty of Engineering, University of Kragujevac,
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2011 in Applied Energy
Verified
Journal Article
Closed access
MBMilorad Bojić
Milorad Bojić
NNNovak Nikolić
Novak Nikolić
Danijela NikolićDanijela Nikolić
Danijela Nikolić
JSJasmina Skerlić
Jasmina Skerlić
IMIvan Miletić
Ivan Miletić

1 August 2015 in Energy
Verified
Journal Article
Closed access
SJSaša Jovanović
Saša Jovanović
SSSlobodan Savić
Slobodan Savić
MBMilorad Bojić
Milorad Bojić
ZDZorica Djordjević
Zorica Djordjević
Danijela NikolićDanijela Nikolić
Danijela Nikolić

1 June 2011 in Energy and Buildings
Verified
Journal Article
Closed access
MBMilorad Bojić
Milorad Bojić
NNNovak Nikolić
Novak Nikolić
Danijela NikolićDanijela Nikolić
Danijela Nikolić
JSJasmina Skerlić
Jasmina Skerlić
IMIvan Miletić
Ivan Miletić

18 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
Danijela NikolićDanijela Nikolić
Danijela Nikolić
SJSasa Jovanovic
Sasa Jovanovic
Nebojša JuriševićNebojša Jurišević
Nebojša Jurišević
NNNovak Nikolić
Novak Nikolić
Jasna RadulovicJasna Radulovic
Jasna Radulovic
IGIsidora Grujić
Isidora Grujić
In modern agriculture today, the cultivation of agricultural products cannot be imagined without greenhouses. This paper presents an energy optimization of a solar greenhouse with a photovoltaic system (PV) and a ground-source heat pump (GSHP). The PV system generates electricity, while the GSHP is used for heating and cooling. A greenhouse is designed with an Open Studio plug-in in the Google SketchUp environment, the EnergyPlus software (8.7.1 version) was used for energy simulation, and the GenOpt software (2.0.0 version) was used for optimization of the azimuth angle and PV cell efficiency. Results for different solar greenhouse orientations and different photovoltaic module efficiency are presented in the paper. The obtained optimal azimuth angle of the solar greenhouse was −8°. With the installation of a PV array with higher module efficiency (20–24%), it is possible to achieve annual energy savings of 6.87–101.77%. Also, with the PV module efficiency of 23.94%, a concept of zero-net-energy solar greenhouses (ZNEG) is achieved at optimal azimuth and slope angle. Through the environmental analysis of different greenhouses, CO2 emissions of PV and GSHP are calculated and compared with electricity usage. Saved CO2 emission for a zero-net-energy greenhouse is 6626 kg CO2/year. An economic analysis of installed renewable energy systems was carried out: with the total investment of 19,326 € for ZNEG, the payback period is 8.63 years.

19 December 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Nebojša JuriševićNebojša Jurišević
Nebojša Jurišević
DGDušan R Gordić
Dušan R Gordić
Danijela NikolićDanijela Nikolić
Danijela Nikolić
Aleksandar Milan NešovićAleksandar Milan Nešović
Aleksandar Milan Nešović
RKRobert Kowalik
Robert Kowalik
One of the barriers to the rapid transition of societies toward a more sustainable future is a scarcity of field experts. Members of scientific and professional communities believe that this obstacle could be overcome by supplementing the decisions of non-experts with artificial intelligence. To examine this opportunity, this study examines the viability of GPT-3.5 as an expert adviser in the energy management of kindergartens. Thus, field experts investigated the deductive and inductive reasoning potential of GPT-LLM (Large Language Model). The first task was conducted on a sample of kindergartens in the Western Balkans. The LLM was instructed to provide the buildings’ specific heat consumption (SHC) by relatively detailed building descriptions and building occupancy. The second task involved kindergartens in various European locations, and the LLM was tasked with estimating energy savings using limited data about the renovation process. The study found deductive reasoning to be insufficient for estimating SHC from the building envelope details, with average accuracy below the least predictive model (R2 = 0.56; MAPE = 48%). Including the factor of occupancy, the SHC estimates were relatively accurate, wherein the first deductive test proved precise (MAPE = 27%), but it was less so in the opposite case (MAPE = 67%). In terms of inductive reasoning, the LLM assumptions were relatively consistent with practice.

3 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
Danijela NikolićDanijela Nikolić
Danijela Nikolić
SDSlobodan Djordjevic
Slobodan Djordjevic
JSJasmina Skerlic
Jasmina Skerlic
Jasna RadulovicJasna Radulovic
Jasna Radulovic
It is well known that nowadays a significant part of the total energy consumption is related to buildings, so research for improving building energy efficiency is very important. This paper presents our investigations about the dimensioning of horizontal overhangs in order to determine the minimum annual consumption of building primary energy for heating, cooling and lighting. In this investigation, embodied energy for horizontal roof overhangs was taken into account. The annual simulation was carried out for a residential building located in the city of Belgrade (Serbia). Horizontal overhangs (roof and balcony) are positioned to provide shading of all exterior of the building. The building is simulated in the EnergyPlus software environment. The optimization of the overhang size was performed by using the Hooke Jeeves algorithm and plug-in GenOpt program. The objective function minimizes the annual consumption of primary energy for heating, cooling and lighting of the building and energy spent to build overhangs. The simulation results show that the building with optimally sized roof and balcony overhangs consumed 7.12% lessprimary energy for heating, cooling and lighting, compared to the house without overhangs. A 44.15% reduction in cooling energy consumption is also achieved.