Aleksandar Milan Nešović

Dr. Aleksandar Milan Nešović

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Nebojša JuriševićNebojša Jurišević
Nebojša Jurišević
DGDušan R Gordić
Dušan R Gordić
Danijela NikolićDanijela Nikolić
Danijela Nikolić
Aleksandar Milan NešovićAleksandar Milan Nešović
Aleksandar Milan Nešović
RKRobert Kowalik
Robert Kowalik
One of the barriers to the rapid transition of societies toward a more sustainable future is a scarcity of field experts. Members of scientific and professional communities believe that this obstacle could be overcome by supplementing the decisions of non-experts with artificial intelligence. To examine this opportunity, this study examines the viability of GPT-3.5 as an expert adviser in the energy management of kindergartens. Thus, field experts investigated the deductive and inductive reasoning potential of GPT-LLM (Large Language Model). The first task was conducted on a sample of kindergartens in the Western Balkans. The LLM was instructed to provide the buildings’ specific heat consumption (SHC) by relatively detailed building descriptions and building occupancy. The second task involved kindergartens in various European locations, and the LLM was tasked with estimating energy savings using limited data about the renovation process. The study found deductive reasoning to be insufficient for estimating SHC from the building envelope details, with average accuracy below the least predictive model (R2 = 0.56; MAPE = 48%). Including the factor of occupancy, the SHC estimates were relatively accurate, wherein the first deductive test proved precise (MAPE = 27%), but it was less so in the opposite case (MAPE = 67%). In terms of inductive reasoning, the LLM assumptions were relatively consistent with practice.

27 April 2024 in Energies
Verified
Journal Article
Open access
PDF file
Aleksandar Milan NešovićAleksandar Milan Nešović
Aleksandar Milan Nešović
RKRobert Kowalik
Robert Kowalik
MBMilan Bojović
Milan Bojović
AJAgata Janaszek
Agata Janaszek
SAStanisław Adamczak
Stanisław Adamczak
The global scientific community is intensively promoting energy-plus buildings. Following the leading world trends, this paper presents a new energy-plus building concept—elevational earth-sheltered buildings with three different types of horizontal overhang photovoltaic-integrated panels: wooden support columns covered with clay tiles, steel pipes as support columns covered with sheet steel, and concrete support columns with concrete coverage. In this instance, the specific multi-numerical case study building model for the city of Kragujevac (located in central Serbia with favorable climatic conditions) was performed over 7 months (from 1 October to 30 April), taking into account the soil temperature, the effects of solar shading, the performance of the heating system—a ground source heat pump—and the characteristics of the artificial and automatic lighting control system. The simulation results show that the optimal depth of a horizontal overhang (energy-plus status) depends on the occupant’s habits, in addition to meteorological conditions. The presented methodology can be used for any other location, both in Europe and the world.

28 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Aleksandar Milan NešovićAleksandar Milan Nešović
Aleksandar Milan Nešović
RKRobert Kowalik
Robert Kowalik
DCDragan Cvetković
Dragan Cvetković
AJAgata Janaszek
Agata Janaszek
This paper presents an analytical method for the dimensioning and selection of the four glass tube collector types: single-glazed with an air layer, single-glazed with a vacuum layer, double-glazed with an air layer, and double-glazed with a vacuum layer. In the first part of the paper (dimensioning phase), the iterative thermal resistance calculation algorithms were developed for all glass tube collector types, whereby the iterative thermal resistance calculation algorithm of the single-glazed tube collector with an air layer was experimentally tested and validated. The second part of the paper (selection phase) uses a multi-criteria decision-making method to determine the optimal glass tube collector design. Unlike other papers, three indicator groups are taken into account in this case: geometric (mass, surface occupation, total surface occupation, volume occupation), economic (manufacturing and exploitation costs), and ecological (embodied energy and greenhouse gas emission). The proposed method is characterized by simple and fast calculations with satisfactory accuracy, which avoids high investment costs (experimental research), approximation and discretization of physical models (numerical research), and a large number of input parameters with boundary conditions (theoretical research). It should be noted that, with certain additions and changes, it can also be applied to other solar thermal collectors, so the authors believe such tools are handy for the global scientific public.

1 January 2023 in Thermal Science
Verified
Journal Article
Open access
PDF file
Aleksandar Milan NešovićAleksandar Milan Nešović
Aleksandar Milan Nešović
NLNebojsa Lukic
Nebojsa Lukic
Nebojša JuriševićNebojša Jurišević
Nebojša Jurišević
DCDragan Cvetkovic
Dragan Cvetkovic
DDDragan Dzunic
Dragan Dzunic
BNBogdan Nedic
Bogdan Nedic
To improve solar collector efficiency, a variety of designs and materials have been introduced into production practice. Studies describing solar collector specifics, therefore, are particularly valuable to the scientific community as they contribute to the overall body of knowledge and constant improvement the in the scientific field. In that regard, the study presented in this paper analyses the thermal performance of the fixed flat-plate collector with an Sn-Al2O3 selective absorber. The fixed flat-plate collector design utilizes gravity water flow in an open loop system. A two-month study was conducted to perform the analysis. The experiment was based on measurements of water flow in the fixed flat-plate col-lector, the water temperature at the fixed flat-plate collector inlet and outlet, and solar radiation intensity on a horizontal surface. Results for three randomly selected measurement days have shown that fixed flat-plate collector can achieve relatively satisfactory values for average daily specific heat power, thermal efficiency, and inlet-outlet water temperature gradient, respectively: June 29 (381.78 W/m2, 60.67%, and 9.06?C), June 30 (364.33 W/m2, 59.43%, and 7.46?C), and July 15 (373.06 W/m2, 59.85%, and 8.69?C). Apart from the relatively good measurement results, this type of solar collector does not require circulating pumps for operation, which brings a double advantage: energy saving and energy production.

1 January 2024 in Thermal Science
Verified
Journal Article
Open access
PDF file
Aleksandar Milan NešovićAleksandar Milan Nešović
Aleksandar Milan Nešović
NLNebojša S. Lukić
Nebojša S. Lukić
MJMladen M. Josijević
Mladen M. Josijević
Nebojša JuriševićNebojša Jurišević
Nebojša Jurišević
NNNovak Nikolić
Novak Nikolić
The current flat-plate solar collectors perform best when their absorbers rotate around their axis. However, with their concentrators, reflectors, and tracking mechanisms, they take up a lot of space and are thus commercially speaking, not the best solutions. This paper proposes a novel solar collector design which employs the (relative) rotation of absorbers, but strives to combine the benefits of fixed and (absolute) tracking solar systems, i.e. volume occupancy from the former and thermal performance from the latter. The findings of our numerical analysis show that, the solar irradiance efficiency of this novel design is 20% higher than that of a fixed flat-plate collector during clear-sky days, and it is equally lower than that of an absolute tracking collector. This paper also introduces a new criterion for describing single-axis tracking solar collectors which should be included in the classifications of solar collectors. Finally, the article, which represents a continuation of our research in the field of solar energy utilization, can contribute to the future development of solar technologies and solve some of the current challenges.

12 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
RKRobert Kowalik
Robert Kowalik
Aleksandar Milan NešovićAleksandar Milan Nešović
Aleksandar Milan Nešović
DCDragan Cvetković
Dragan Cvetković
AJAgata Janaszek
Agata Janaszek
TKTomasz Kozlowski
Tomasz Kozlowski
Although the European residential sector has promoted various heating and cooling passive solar systems in many ways, ongoing climate changes affect these construction elements at an annual level. Using the weather files for three years in the recent past (2018, 2021 and 2023), this paper numerically investigates the energy, environmental and economic performance of two small single-family houses equipped with Trombe walls and fixed horizontal overhangs of different depths (0 m, 0.25 m, 0.5 m, 0.75 m and 1 m) for two characteristic European climate zones: continental (Kielce city, Poland) and moderate continental (Kragujevac city, Serbia). Both houses were created in Google SketchUp 8 software using current Statistical data and Rulebooks of energy efficiency, while adopted heating (gas boiler and radiators) and cooling (individual air-conditioning units) active thermo-technical systems were simulated in EnergyPlus 7.1 software using official specific energy, environmental and economic indicators. Compared to the appropriate reference houses—without mentioning passive solar systems—the main results of this study are as follows: (1) higher outdoor air temperatures can reduce final (thermal) energy consumption for heating by 37.74% (for the Kielce climate zone) and 52.49% (for the Kragujevac climate zone); (2) higher outdoor air temperatures can increase final (electricity) energy consumption for cooling between 5.71 and 11.75 times (for Kielce) and 4.36 and 9.81 times (for Kragujevac); (3) percentage savings of primary energy consumption and monetary savings are highest when houses are equipped with Trombe walls and 1 m deep overhangs; and (4) all considered cases of passive solar systems do not contribute to the reduction of greenhouse gas emissions. Since climate change is a consequence of greenhouse gas emissions, priority should be given to environmental indicators in future investigations.