Qi Yang

Mr. Qi Yang

School of Electrical and Automation, Henan Polytechnic University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
GHGelin Huang
Gelin Huang
Fujun MaFujun Ma
Fujun Ma
HDHongqi Ding
Hongqi Ding
QYQi Yang
Qi Yang
RFRui Fan
Rui Fan
LWLei Wang
Lei Wang
Due to the specificity of continuous casting production, the application of ac/ac MMC structure in induction heating power supply requires the realization of frequency conversion from grid AC to low and medium single-phase AC, which makes the conventional modeling methods inappropriate. In this article, an HSS-based reduced order impedance model is proposed. Firstly, due to the complexity of the internal harmonics, the harmonic attenuation of the internal signals is calculated quantitatively by analyzing the three-dimensional signal-flow graph and then the harmonic frequencies are truncated, which provide a basis for model simplification. Furthermore, to precisely describe the amplitude-phase characteristics of the ac/ac MMC under different output frequencies, the harmonic state space modeling method is improved by combining the double Fourier integral transform. Finally, the correctness of the frequency analysis and the accuracy of the reduced order model are verified.

1 January 2020 in International Journal of Performability Engineering
Verified
Journal Article
Closed access
PDF file
TSTian Shu
Tian Shu
QYQi Yang
Qi Yang
XYXu Yao
Xu Yao

13 October 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
STShu Tian
Shu Tian
QYQi Yang
Qi Yang
YXYao Xu
Yao Xu
TZTengfei Zhang
Tengfei Zhang
Fault transient traveling waves in hybrid transmission lines are complex and varied. Hence, this study proposes a method for fault location on the basis of the traveling wave polarity, combining single-ended and double-ended traveling wave ranging algorithms. First, the approximate reflected wave time is calculated based on the distance measured by the double-ended traveling wave ranging algorithms. Then, on the basis of the polarity of the traveling wave, the wave reflected from the point where the fault occurs and the joint point of the hybrid line are accurately identified. Finally, after the reflected wave is accurately identified, the fault is accurately located. In the application of double-ended traveling wave method, variational mode decomposition (VMD) and Teager energy operator (TEO) are used to improve the accuracy of the initial fault distance calculation. The algorithm proposed in this study can ignore the errors caused by the time synchronization and the difficulty in identifying the reflected wave. Simulation results show that the algorithm proposed in this study has high measurement accuracy.