Shahin Sohrabi

Dr. Shahin Sohrabi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSShahin Sohrabi
Shahin Sohrabi
TPTeresa Pàmies
Teresa Pàmies
JGJordi Romeu Garbí
Jordi Romeu Garbí
Barriers are increasingly used to protect the pedestrian and neighboring buildings from construction noise activities. This study aims to investigate the suitability of applying active noise control on barriers in a construction site to protect the street area and neighboring buildings. Transducers that are simulated in this work are close to the barrier, and their optimal positions are defined in such a way that the control system has the maximum performance at the neighboring areas close to the construction sites. To begin with, the suitable location of the control sources is found when the total squared pressure is minimized at the positions of noise receivers. The suitable location of the error sensors is, then, found when the control sources are fixed at the position of the previous step and the total squared pressure is minimized at the error sensors. The best location for the error sensors is defined when the maximum reduction is achieved in the target area. It is observed that suitable positions for the transducers depend on the location of target areas for noise control, the position of the noise source, and its operating frequency. In this investigation, a unique configuration is proposed for the transducers that achieves a comparable reduction both at the street area and the neighboring buildings, simultaneously. The results show that the active noise barrier with a height of 2.5 m can achieve an extra insertion loss in the street zone, varies from 9.3 to 16.4 dB (in comparison with passive noise barrier) when the distance of the noise source from the barrier changes in the range of 7 to 1 m, respectively. Those values are of the same order for the passive noise attenuation. Furthermore, similar results are achieved when attempting to cancel the shadow zone of a façade 15 m away from the barrier.

15 April 2022 in Journal of Vibration and Control
Verified
Journal Article
Closed access
SSShahin Sohrabi
Shahin Sohrabi
TGTeresa Pàmies Gómez
Teresa Pàmies Gómez
JGJordi Romeu Garbí
Jordi Romeu Garbí
The main intention of this study is to propose general criteria for the locations of the control sources and error microphones that improve the performance of the active noise barrier. Based on the proposed criteria of this study, the greater reduction is attained when the diffracted field of the noise source is canceled with the diffracted field of the control sources, that is, it is suggested to locate the control sources on the incident side and below the path that connects the furthest point in the shadow zone to the edge of the barrier. Furthermore, it is suggested that the error microphones are most suitably placed on the shadow side of the barrier where they are under the diffracted field of both the primary and control sources. The results also show that with these general criteria, the active noise control achieves an extra reduction that varies from 14.9 to 3.9 dB (for the one-third octave bands from 63 Hz to 1 kHz) and 9.3 dB for the broadband noises.

8 November 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SSShahin Sohrabi
Shahin Sohrabi
ATAmadeu Segura Torres
Amadeu Segura Torres
EMEster Cierco Molins
Ester Cierco Molins
APAlessandro Perazzolo
Alessandro Perazzolo
GBGiuseppe Bizzarro
Giuseppe Bizzarro
PSPere Vicenç Rodríguez Sorribes
Pere Vicenç Rodríguez Sorribes
The excessive noise present within an aircraft cabin during flight operations constitutes a notable origin of fatigue, stress, and communication impediments for both pilots and passengers. Ensuring the comfort, well-being, and safety of passengers and crew members necessitates the accurate anticipation of noise levels. This study concerns the computation of structure-borne noise levels within the cabin of a tiltrotor aircraft. This investigation employed two distinct methodologies: advanced transfer path analysis (ATPA) and statistical energy analysis (SEA). To assess the results obtained with the ATPA approach, the acquired outcomes were compared with empirically measured sound pressure levels during airplane mode operations. The contributions of air-borne and structure-borne noises were calculated with the ATPA methodology. On the other hand, the structure-borne noise was calculated with a hybrid experimental–SEA model with ACTRAN software, and its results were compared with those of the ATPA method. The results show a good agreement between these methods at high frequencies, while at low frequencies, certain adjustments or modifications to the SEA model are necessary to predict the noise levels.

31 July 2023 in Journal of Low Frequency Noise, Vibration and Active Control
Verified
Journal Article
Open access
SSShahin Sohrabi
Shahin Sohrabi
TGTeresa Pàmies Gómez
Teresa Pàmies Gómez
JGJordi Romeu Garbí
Jordi Romeu Garbí
The effectiveness of an active noise barrier is heavily dependent on the positioning of secondary sources and error sensors. Typically, these components are located at the edge of the barrier; however, research suggests that alternative distributions may improve the performance of the active barrier. This paper utilizes a genetic optimizer to determine optimal transducer locations based on specific criteria. Two approaches are employed: the Two-step approach which, first identifies optimal control source positions and then seeks the best error microphone locations, and the Multi-parameter approach, which optimizes all active noise control parameters simultaneously. The acoustic fields of primary and secondary sources are analyzed for various numbers of control sources progressively increasing from 2 to 10 units. Results indicate that the Multi-parameter approach achieves higher outcomes and requires less computational effort. This approach is more desirable than the Two-step approach. The best configuration for the active noise barrier is determined to be control sources and error microphones placed at a height below the barrier’s edge and are distributed with an interval between a half and a full wavelength. The number of error sensors should be close to the number of secondary sources and both transducers should be placed at the farthest distance from the barrier surface, but oppositely. Furthermore, the study shows that when the primary noise source is close to the barrier adjacent transducers should not be spaced uniformly.

1 August 2021 in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
Verified
Journal Article
Closed access
SSShahin Sohrabi
Shahin Sohrabi
PSPeter Svensson
Peter Svensson
TPTeresa Pàmies
Teresa Pàmies
JGJordi Romeu Garbi
Jordi Romeu Garbi
Over the last decades, the applications of the active noise control system are broadened. In this study, the active noise control is modeled to reduce the noise pass through an open window. The objective is to define a suitable location for the control sources and error microphones to achieve more noise level reduction at the other side of the window. The performances of the active noise control system are calculated for two different arrangements: (1) the control sources on the edge of the opening and (2) the control sources distributed on the surface of the window. Furthermore, two cost functions are considered to model the noise control system including the minimization of the total squared pressure at cancellation points and the minimization of sound intensity at the surface of the aperture.