Inti Vanmechelen

Dr. Inti Vanmechelen

KU Leuven (Belgium)
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Frontiers in Robotics and AI
Verified
Journal Article
Open access
IVInti Vanmechelen
Inti Vanmechelen
HHHelga Haberfehlner
Helga Haberfehlner
JVJoni De Vleeschhauwer
Joni De Vleeschhauwer
EWEllen Van Wonterghem
Ellen Van Wonterghem
HFHilde Feys
Hilde Feys
EMElegast Monbaliu
Elegast Monbaliu
Background:Studies aiming to objectively quantify movement disorders during upper limb tasks using wearable sensors have recently increased, but there is a wide variety in described measurement and analyzing methods, hampering standardization of methods in research and clinics. Therefore, the primary objective of this review was to provide an overview of sensor set-up and type, included tasks, sensor features and methods used to quantify movement disorders during upper limb tasks in multiple pathological populations. The secondary objective was to identify the most sensitive sensor features for the detection and quantification of movement disorders on the one hand and to describe the clinical application of the proposed methods on the other hand.Methods:A literature search using Scopus, Web of Science, and PubMed was performed. Articles needed to meet following criteria: 1) participants were adults/children with a neurological disease, 2) (at least) one sensor was placed on the upper limb for evaluation of movement disorders during upper limb tasks, 3) comparisons between: groups with/without movement disorders, sensor features before/after intervention, or sensor features with a clinical scale for assessment of the movement disorder. 4) Outcome measures included sensor features from acceleration/angular velocity signals.Results:A total of 101 articles were included, of which 56 researched Parkinson’s Disease. Wrist(s), hand(s) and index finger(s) were the most popular sensor locations. Most frequent tasks were: finger tapping, wrist pro/supination, keeping the arms extended in front of the body and finger-to-nose. Most frequently calculated sensor features were mean, standard deviation, root-mean-square, ranges, skewness, kurtosis/entropy of acceleration and/or angular velocity, in combination with dominant frequencies/power of acceleration signals. Examples of clinical applications were automatization of a clinical scale or discrimination between a patient/control group or different patient groups.Conclusion:Current overview can support clinicians and researchers in selecting the most sensitive pathology-dependent sensor features and methodologies for detection and quantification of upper limb movement disorders and objective evaluations of treatment effects. Insights from Parkinson’s Disease studies can accelerate the development of wearable sensors protocols in the remaining pathologies, provided that there is sufficient attention for the standardisation of protocols, tasks, feasibility and data analysis methods.

1 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
IVInti Vanmechelen
Inti Vanmechelen
SBSaranda Bekteshi
Saranda Bekteshi
HHHelga Haberfehlner
Helga Haberfehlner
HFHilde Feys
Hilde Feys
KDKaat Desloovere
Kaat Desloovere
EMElegast Monbaliu
Elegast Monbaliu
Background—Movement patterns in dyskinetic cerebral palsy (DCP) are characterized by abnormal postures and involuntary movements. Current evaluation tools in DCP are subjective and time-consuming. Sensors could yield objective information on pathological patterns in DCP, but their reliability has not yet been evaluated. The objectives of this study were to evaluate (i) reliability and (ii) discriminative ability of sensor parameters. Methods—Inertial measurement units were placed on the arm, forearm, and hand of individuals with and without DCP while performing reach-forward, reach-and-grasp-vertical, and reach-sideways tasks. Intra-class correlation coefficients (ICC) were calculated for reliability, and Mann–Whitney U-tests for between-group differences. Results—Twenty-two extremities of individuals with DCP (mean age 16.7 y) and twenty individuals without DCP (mean age 17.2 y) were evaluated. ICC values for all sensor parameters except jerk and sample entropy ranged from 0.50 to 0.98 during reach forwards/sideways and from 0.40 to 0.95 during reach-and-grasp vertical. Jerk and maximal acceleration/angular velocity were significantly higher for the DCP group in comparison with peers. Conclusions—This study was the first to assess the reliability of sensor parameters in individuals with DCP, reporting high between- and within-session reliability for the majority of the sensor parameters. These findings suggest that pathological movements of individuals with DCP can be reliably captured using a selection of sensor parameters.

31 October 2022 in Developmental Medicine & Child Neurology
Verified
Journal Article
Closed access
IVInti Vanmechelen
Inti Vanmechelen
ADAnnika Danielsson
Annika Danielsson
CLCecilia Lidbeck
Cecilia Lidbeck
KTKristina Tedroff
Kristina Tedroff
EMElegast Monbaliu
Elegast Monbaliu
LKLena Krumlinde‐Sundholm
Lena Krumlinde‐Sundholm

13 December 2019 in Developmental Medicine & Child Neurology
Verified
Journal Article
Closed access
PDF file
IVInti Vanmechelen
Inti Vanmechelen
BDBernard Dan
Bernard Dan
HFHilde Feys
Hilde Feys
EMElegast Monbaliu
Elegast Monbaliu

8 January 2019 in Disability and Rehabilitation
Verified
Journal Article
Closed access
IVInti Vanmechelen
Inti Vanmechelen
SBSaranda Bekteshi
Saranda Bekteshi
KBKyra Bossier
Kyra Bossier
HFHilde Feys
Hilde Feys
JDJan Deklerck
Jan Deklerck
EMElegast Monbaliu
Elegast Monbaliu
Background: This cross-sectional study aims to investigate the presence and severity of overflow movements of dystonia and choreoathetosis in dyskinetic cerebral palsy (CP) and to assess the relationship of overflow movements with functional classification scales. Methods: Fifty-two subjects with dyskinetic CP were included. Presence and severity of dystonia and choreoathetosis overflow movements were assessed with the Dyskinesia Impairment Scale. Functional abilities were classified with the Gross Motor Function Classification System, Manual Ability Classification System, Viking Speech Scale, Communication Function Classification System, and Eating and Drinking Ability Classification System. Results: Dystonia and choreoathetosis overflow movements were simultaneously present. Median scores of dystonia overflow movements were significantly higher than choreoathetosis overflow movements. Dystonia and choreoathetosis overflow movements were significantly higher in extremities than in the central body. Correlations between dystonia and choreoathetosis overflow movements were fair. Moderate to good correlations were found between dystonia overflow score and Gross Motor Function Classification System, Manual Ability Classification System, and Eating and Drinking Ability Classification System. Conclusions: This is the first study to assess overflow movements in dyskinetic CP. All participants presented with dystonia and choreoathetosis overflow movements, with higher values for dystonia overflow movements. Dystonia overflow movements seem to have a larger impact on functional abilities.

23 September 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
IVInti Vanmechelen
Inti Vanmechelen
SBSaranda Bekteshi
Saranda Bekteshi
MKMarco Konings
Marco Konings
HFHilde Feys
Hilde Feys
KDKaat Desloovere
Kaat Desloovere
EMElegast Monbaliu
Elegast Monbaliu
Dyskinetic cerebral palsy (DCP) is characterised by involuntary movements, and the movement patterns of children with DCP have not been extensively studied during upper limb tasks. The aim of this study is to evaluate psychometric properties of upper limb kinematics in participants with DCP and typically developing (TD) participants. In current repeatability and validity study, forty individuals with typical development (n = 20) and DCP (n = 20) performed a reach forward/sideways and a reach and grasp task during motion analysis on two occasions. Joint angles at point of task achievement (PTA) and spatio-temporal parameters were evaluated within-and between-sessions using intra-class correlation coefficients (ICC) and standard error of measurement (SEM). Independent t-tests/Mann-Whitney-U tests were used to compare parameters between groups. Within-session ICC values ranged from 0.45 to 1.0 for all parameters for both groups. Within-session SEM values ranged from 1.1° to 11.7° for TD participants and from 1.9° to 13.0° for participants with DCP. Eight within-session repetitions resulted in the smallest change in ICC and SEM values for both groups. Within-session variability was higher for participants with DCP in comparison with the TD group for the majority of the joint angles and spatio-temporal parameters. Intrinsic variability over time was small for all angles and spatio-temporal parameters, whereas extrinsic variability was higher for elbow and scapula angles. Between-group differences revealed lower shoulder adduction and higher elbow flexion, pronation and wrist flexion, as well as higher trajectory deviation and a lower maximal velocity for participants with DCP. This is the first study to assess the psychometric properties of upper limb kinematics in children and adolescents with DCP, showing that children with DCP show higher variability during task execution, requiring a minimum of eight repetitions. However, their variable movement pattern can be reliably captured within-and between-sessions, confirming the potential of three-dimensional motion analysis for assessment of rehabilitation interventions in DCP.