Rebekah Martin

Dr. Rebekah Martin

Virginia Military Institute
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2018 in Environmental Science & Technology
Verified
Journal Article
Open access
KPKelsey J. Pieper
Kelsey J. Pieper
RMRebekah Martin
Rebekah Martin
MTMin Tang
Min Tang
LWLeeAnne Walters
LeeAnne Walters
JPJeffrey Parks
Jeffrey Parks
MEMarc A. Edwards
Marc A. Edwards
In April 2014, the drinking water source in Flint, Michigan was switched from Lake Huron water with phosphate inhibitors to Flint River water without corrosion inhibitors. The absence of corrosion control and use of a more corrosive source increased lead leaching from plumbing. Our city-wide citizen science water lead results contradicted official claims that there was no problem– our 90th percentile was 26.8 µg/L, which was almost double the Lead and Copper Rule action level of 15 µg/L. Back calculations of a LCR sampling pool with 50% lead pipes indicated an estimated 90th percentile lead value of 31.7 µg/L (±4.3 µg/L). Four subsequent sampling efforts were conducted to track reductions in water lead after the switch back to Lake Huron water and enhanced corrosion control. The incidence of water lead varied by service line material. Between August 2015 and November 2016, median water lead reduced from 3.0 to <1 µg/L for homes with copper service lines, 7.2 to 1.9 µg/L with galvanized service lines, and 9.9 to 2.3 µg/L with lead service lines. As of summer 2017, our 90th percentile of 7.9 µg/L no longer differed from official results, which indicated Flint’s water lead levels were below the action level.

17 November 2020 in Pathogens
Verified
Journal Article
Open access
PDF file
ACAbraham Cullom
Abraham Cullom
RMRebekah Martin
Rebekah Martin
YSYang Song
Yang Song
KWKrista Williams
Krista Williams
AWAmanda Williams
Amanda Williams
MEMarc Edwards
Marc Edwards
Growth of Legionella pneumophila and other opportunistic pathogens (OPs) in drinking water premise plumbing poses an increasing public health concern. Premise plumbing is constructed of a variety of materials, creating complex environments that vary chemically, microbiologically, spatially, and temporally in a manner likely to influence survival and growth of OPs. Here we systematically review the literature to critically examine the varied effects of common metallic (copper, iron) and plastic (PVC, cross-linked polyethylene (PEX)) pipe materials on factors influencing OP growth in drinking water, including nutrient availability, disinfectant levels, and the composition of the broader microbiome. Plastic pipes can leach organic carbon, but demonstrate a lower disinfectant demand and fewer water chemistry interactions. Iron pipes may provide OPs with nutrients directly or indirectly, exhibiting a high disinfectant demand and potential to form scales with high surface areas suitable for biofilm colonization. While copper pipes are known for their antimicrobial properties, evidence of their efficacy for OP control is inconsistent. Under some circumstances, copper’s interactions with premise plumbing water chemistry and resident microbes can encourage growth of OPs. Plumbing design, configuration, and operation can be manipulated to control such interactions and health outcomes. Influences of pipe materials on OP physiology should also be considered, including the possibility of influencing virulence and antibiotic resistance. In conclusion, all known pipe materials have a potential to either stimulate or inhibit OP growth, depending on the circumstances. This review delineates some of these circumstances and informs future research and guidance towards effective deployment of pipe materials for control of OPs.

22 September 2020 in Microorganisms
Verified
Journal Article
Open access
PDF file
RMRebekah Martin
Rebekah Martin
KHKara Harrison
Kara Harrison
CPCaitlin R. Proctor
Caitlin R. Proctor
AMAmanda Martin
Amanda Martin
KWKrista Williams
Krista Williams
MEMarc Edwards
Marc Edwards
Premise plumbing conditions can contribute to low chlorine or chloramine disinfectant residuals and reactions that encourage opportunistic pathogen growth and create risk of Legionnaires’ Disease outbreaks. This bench-scale study investigated the growth of Legionella spp. and Acanthamoeba in direct contact with premise plumbing materials—glass-only control, cross-linked polyethylene (PEX) pipe, magnesium anode rods, iron pipe, iron oxide, pH 10, or a combination of factors. Simulated glass water heaters (SGWHs) were colonized by Legionella pneumophila and exposed to a sequence of 0, 0.1, 0.25, and 0.5 mg/L chlorine or chloramine, at two levels of total organic carbon (TOC), over 8 weeks. Legionella pneumophila thrived in the presence of the magnesium anode by itself and or combination with other factors. In most cases, 0.5 mg/L Cl2 caused a significant rapid reduction of L. pneumophila, Legionella spp., or total bacteria (16S rRNA) gene copy numbers, but at higher TOC (>1.0 mg C/L), a chlorine residual of 0.5 mg/L Cl2 was not effective. Notably, Acanthamoeba was not significantly reduced by the 0.5 mg/L chlorine dose.

4 September 2020 in Pathogens
Verified
Journal Article
Open access
PDF file
RMRebekah Martin
Rebekah Martin
OSOwen R. Strom
Owen R. Strom
APAmy Pruden
Amy Pruden
MEMarc Edwards
Marc Edwards
Flint, MI experienced two outbreaks of Legionnaires’ Disease (LD) during the summers of 2014 and 2015, coinciding with use of Flint River as a drinking water source without corrosion control. Using simulated distribution systems (SDSs) followed by stagnant simulated premise (i.e., building) plumbing reactors (SPPRs) containing cross-linked polyethylene (PEX) or copper pipe, we reproduced trends in water chemistry and Legionella proliferation observed in the field when Flint River versus Detroit water were used before, during, and after the outbreak. Specifically, due to high chlorine demand in the SDSs, SPPRs with treated Flint River water were chlorine deficient and had elevated L. pneumophila numbers in the PEX condition. SPPRs with Detroit water, which had lower chlorine demand and higher residual chlorine, lost all culturable L. pneumophila within two months. L. pneumophila also diminished more rapidly with time in Flint River SPPRs with copper pipe, presumably due to the bacteriostatic properties of elevated copper concentrations caused by lack of corrosion control and stagnation. This study confirms hypothesized mechanisms by which the switch in water chemistry, pipe materials, and different flow patterns in Flint premise plumbing may have contributed to observed LD outbreak patterns.

29 July 2022 in ACS ES&T Water
Verified
Journal Article
Closed access
RMRebekah Martin
Rebekah Martin
OSOwen Strom
Owen Strom
YSYang Song
Yang Song
DMDidier Mena-Aguilar
Didier Mena-Aguilar
WRWilliam Rhoads
William Rhoads
MEMarc Edwards
Marc Edwards

17 July 2025 in Environmental Science & Technology Letters
Verified
Journal Article
Open access
FRFernando A. Roman
Fernando A. Roman
TBThomas Byrne
Thomas Byrne
RMRebekah Martin
Rebekah Martin
DMDidier Mena-Aguilar
Didier Mena-Aguilar
RSRania E. Smeltz
Rania E. Smeltz
MEMarc Edwards
Marc Edwards
(Lp) can sometimes establish in drinking water microbial communities and infect individuals inhaling contaminated aerosols. The premise plumbing portion of the drinking water distribution system is often especially vulnerable to Lp growth. Innovative approaches to intentionally manipulate the microbial ecology to control Lp have been proposed but remain elusive. Here, we retrospectively analyzed 16S rRNA gene amplicon sequences and droplet digital PCR data in samples derived from prior drinking water studies, wherein some inexplicable stochastic variations in the Lp occurrence were observed in replicate microcosms. We discovered an apparent antagonistic relationship between and . This relationship was noted across three water sources (Flint, Detroit, and Blacksburg) and was at least partially mediated by the presence of copper, through either copper pipes or a dosed range of 0–2000 μg/L total copper. The observations of this study, which was conducted under realistic drinking water conditions harboring mixed microbial communities, are consistent with recent pure culture studies reporting that amoebic uptake may be inhibited when are established as amoebal endosymbionts. The findings may help explain the apparent stochastic behavior of Lp in field and research settings and may open a door to new engineered ecological control strategies for Lp.