This study was conducted to develop a proportional-integral-derivative (PID) control algorithm considering viscosity for the planting depth control system of a rice transplanter using various hydraulic oils at different temperatures and to evaluate the performance of the control algorithm, and compare the performance of the PID control algorithm without considering viscosity and considering viscosity. In this study, the simulation model of the planting depth control system and a PID control algorithm were developed based on the power flow of the rice transplanter (ERP60DS). The primary PID coefficients were determined using the Ziegler-Nichols (Z-N) second method. Routh’s stability criteria were applied to optimize the coefficients. The pole and double zero points of the PID controller were also applied to minimize the sustained oscillations of the responses. The performance of the PID control algorithm was evaluated for three ISO (The International Organization for Standardization) standard viscosity grade (VG) hydraulic oils (VG 32, 46, and 68). The response characteristics were analyzed using statistical method (ANOVA) and Duncan’s multiple range test (DMRT) at a significant level of 0.05 were performed through the statistical software SPSS. The results show that the control algorithm considering viscosity is able to control the pressure of the proportional valve, which is associated with the actuator displacement for various types of hydraulic oils. It was noticed that the maximum pressure was 15.405 bars at 0, 20, 40, 60, 80, and 100 °C for all of the hydraulic oils. The settling time and steady-state errors were 0.45 s at 100 °C for VG 32 and 0% for all of the conditions. The maximum overshoots were found to be 17.50% at 100 °C for VG 32. On the other hand, the PID control algorithm without considering viscosity could not control the planting depth, because the response was slow and did not satisfy the boundary conditions. The PID control algorithm considering viscosity could sufficiently compensate for the nonlinearity of the hydraulic system and was able to perform for any of temperature-dependent viscosity of the hydraulic oils. In addition, the rice transplanter requires a faster response for accurately controlling and maintaining the planting depth. Planting depth is highly associated with actuator displacement. Finally, this control algorithm considering viscosity could be helpful in minimizing the tilting of the seedlings planted using the rice transplanter. Ultimately, it would improve the transplanter performance.
This study aims to develop and evaluate an automated manual transmission (AMT) for agricultural tractors with high efficiency and high convenience by using electric actuators. An AMT system to control manual-type shuttle gearboxes and transmissions for tractors is developed by adding a shuttle shifting actuator, a clutch actuator, and a control system to a conventional manual transmission (MT). The clutch actuator is designed using an electric motor and a reduction gear. The AMT control system is developed and experimental tests are conducted to evaluate the performance of the AMT. The results of the performance of the actuator position control demonstrate that the shuttle shifting actuator and clutch actuator are controlled appropriately, achieving a maximum overshoot of less than 5% and 0%, a settling time of less than 0.500 s and 1.50 s, and a steady-state error of less than 1% and 1%, respectively. The performance of the automatic forward and reverse control demonstrates a shift control time of less than 2.50 s and target revolutions per minute (RPM) reaching time of less than 3.00 s. Thus, AMT systems for tractors can be easily developed by applying shuttle shifting actuators, clutch actuators, and a control system to conventional manual transmissions.