This paper deals with optimal scheduling of networked microgrids (NMGs) considering resilience constraints. The proposed scheme attempts to mitigate the damaging impacts of electricity interruptions by effectively exploiting NMG capabilities. A three-stage framework is proposed. In Stage 1, the optimal scheduling of NMGs is studied through determining the power transaction between the NMGs and upstream network, the output power of distributed energy resources (DERs), commitment status of conventional DERs as well as demand-side reserves. In Stage 2, the decisions made at Stage 1 are realized considering uncertainties pertaining to renewable generation, market price, power consumption of loads, and unintentional islanding of NMGs from the upstream network and resynchronization. Stage 3 deals with uncertainties of unintentional islanding of each MG from the rest of islanded NMGs and resynchronization. The problem is formulated as a mixed-integer linear programming problem and its effectiveness is assured by simulation studies.
Electricity generation from renewable energy sources (RES) has a common feature, that is, it is fluctuating, available in certain amounts and only for some periods of time. Consuming this electricity when it is available should be a primary goal to enhance operation of the RES-powered generating units which are particularly operating in microgrids. Heavily influenced by weather parameters, RES-powered systems can benefit from implementation of sensors and fuzzy logic systems to dynamically adapt electric loads to the volatility of RES. This study attempts to answer the following question: How to efficiently integrate RES to power systems by means of sustainable energy solutions that involve sensors, fuzzy logic, and categorization of loads? A Smart Adaptive Switching Module (SASM) architecture, which efficiently uses electricity generation of local available RES by gradually switching electric appliances based on weather sensors, power forecast, storage system constraints and other parameters, is proposed. It is demonstrated that, without SASM, the RES generation is supposed to be curtailed in some cases, e.g., when batteries are fully charged, even though the weather conditions are favourable. In such cases, fuzzy rules of SASM securely mitigate curtailment of RES generation by supplying high power non-traditional storage appliances. A numerical case study is performed to demonstrate effectiveness of the proposed SASM architecture for a RES system located in Hulubești (Dâmbovița), Romania.
27 December 2018 in Journal of Modern Power Systems and Clean Energy
Uncertainties in wind power forecast, day-ahead and imbalance prices for the next day possess a great deal of risk for the profit of generation companies participating in a day-ahead electricity market. Generation companies are exposed to imbalance penalties in the balancing market for unordered mismatches between associated day-ahead power schedule and real-time generation. Coordination of wind and thermal power plants alleviates the risks raised from wind uncertainties. This paper proposes a novel optimal coordination strategy by balancing wind power forecast deviations with thermal units in the Turkish day-ahead electricity market. The main focus of this study is to provide an optimal trade-off between the expected profit and the risk under wind uncertainty through conditional value at risk (CVaR) methodology. Coordination problem is formulated as a two-stage mixed-integer stochastic programming problem, where scenario-based wind power approach is used to handle the stochasticity of the wind power. Dynamic programming approach is utilized to attain the commitment status of thermal units. Profitability of the coordination with different day-ahead bidding strategies and trade-off between expected profit and CVaR are examined with comparative scenario studies.
22 April 2021 in Energy Sources, Part B: Economics, Planning, and Policy
This study investigates the impacts of integrating electrical vehicles to pilot distribution grids in Turkey to quantify technical concerns and solutions for the year 2030. Different charging loads that discern home, workplace and public charging are considered under two different cases; “home-charging-support” and “public-charging-support.” Random variables describing arrival time of electrical vehicles to the charging stations and associated state of charge at arrival time are modeled with a stochastic approach. Dependencies of electrical vehicle integration capacities of the pilot regions are investigated quantitatively based on several key performance indices. The study also analyzes effects on key performance indicators of demand response by electrical vehicle users, defined as smart charging. Key results show that there is sufficient capacity in the four selected Turkish distribution grids to integrate almost 10% electrical vehicles in the vehicle stock by 2030. Based on the results, priority areas are outlined for stakeholders including energy policymakers.
13 November 2018 in IEEE Transactions on Sustainable Energy
Elektrikli araçların (EA) sayısı arttıkça, EA’ların şarj yükünün güç dağıtım şebekelerine ilave yük bindireceği ve sorunlar yaşanabileceği güncel tartışılan bir konudur. EA’ların şarj maliyetini şebekenin yükünün düşük olduğu saatlere kaydırmaya yönelik akıllı mekanizmalar bir çözüm olarak değerlendirilmektedir. Bu çalışmada, EA’ların şebekeye entegrasyonu sonrası bu tür ihtiyaçlar ve çözümler analiz edilmiştir. Bu amaçla, 2030 yılında Türkiye’de sayıları önemli ölçüde artması beklenen EA’ların şebekeye etkilerine yönelik olarak, pilot bir dağıtım şebekesinde, senaryo bazlı simülasyonlar gerçekleştirilmiştir. EA’ların pilot dağıtım şebekesi üzerindeki etkilerini değerlendirmek için, ilk önce hedef yıl olan 2030 için bir referans şebeke modeli (EA şarj yükü olmayan) geliştirilmiştir. Daha sonra, farklı teknolojilerdeki (yavaş ve hızlı şarj) EA şarj noktaları, yoğunlukla evlerde şarj ve yoğunlukla işyerlerinde ve kamusal alanlarda şarj senaryoları için ayrı ayrı olmak üzere, bu referans şebeke modeline ilave edilmiştir. Rastgele değişkenler olan EA’ların şarj istasyonlarına varış zamanı ve varış zamanında şarj durumu (SOC) stokastik yaklaşımlar ile modellenmiştir. EA’ların şebekeye entegrasyonunun etkileri, ekipmanların (transformatör ve hatlar) yıllık doluluk oranı (%), aşırı yüklenme (%) ve aşırı gerilim düşümü (%) açılarından incelenmiştir.