FREDERIC CHORIN

Dr. FREDERIC CHORIN

Centre Hospitalier Universitaire de Nice, Nice, Provence-Alpes-Côte d’Azur, France

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2022 in Cancers
Verified
Journal Article
Open access
PDF file
CTCécile Torregrosa
Cécile Torregrosa
FCFREDERIC CHORIN
FREDERIC CHORIN
EBEva Ester Molina Beltran
Eva Ester Molina Beltran
CNCindy Neuzillet
Cindy Neuzillet
VCVictoire Cardot-Ruffino
Victoire Cardot-Ruffino
Multidisciplinary supportive care, integrating the dimensions of exercise alongside oncological treatments, is now regarded as a new paradigm to improve patient survival and quality of life. Its impact is important on the factors that control tumor development, such as the immune system, inflammation, tissue perfusion, hypoxia, insulin resistance, metabolism, glucocorticoid levels, and cachexia. An increasing amount of research has been published in the last years on the effects of physical activity within the framework of oncology, marking the appearance of a new medical field, commonly known as “exercise oncology”. This emerging research field is trying to determine the biological mechanisms by which, aerobic exercise affects the incidence of cancer, the progression and/or the appearance of metastases. We propose an overview of the current state of the art physical exercise interventions in the management of cancer patients, including a pragmatic perspective with tips for routine practice. We then develop the emerging mechanistic views about physical exercise and their potential clinical applications. Moving toward a more personalized, integrated, patient-centered, and multidisciplinary management, by trying to understand the different interactions between the cancer and the host, as well as the impact of the disease and the treatments on the different organs, this seems to be the most promising method to improve the care of cancer patients.

5 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MDMathis D'Haene
Mathis D'Haene
FCFREDERIC CHORIN
FREDERIC CHORIN
SCSerge Sébastien Colson
Serge Sébastien Colson
OGOlivier Guérin
Olivier Guérin
RZRaphaël Zory
Raphaël Zory
EPElodie Piche
Elodie Piche
Gait analysis is essential for evaluating walking patterns and identifying functional limitations. Traditional marker-based motion capture tools are costly, time-consuming, and require skilled operators. This study evaluated a 3D Marker-less Motion Capture (3D MMC) system using pose and depth estimations with the gold-standard Motion Capture (MOCAP) system for measuring hip and knee joint angles during gait at three speeds (0.7, 1.0, 1.3 m/s). Fifteen healthy participants performed gait tasks which were captured by both systems. The 3D MMC system demonstrated good accuracy (LCC > 0.96) and excellent inter-session reliability (RMSE < 3°). However, moderate-to-high accuracy with constant biases was observed during specific gait events, due to differences in sample rates and kinematic methods. Limitations include the use of only healthy participants and limited key points in the pose estimation model. The 3D MMC system shows potential as a reliable tool for gait analysis, offering enhanced usability for clinical and research applications.

4 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JHJustine Hellec
Justine Hellec
FCFREDERIC CHORIN
FREDERIC CHORIN
ACAndrea Castagnetti
Andrea Castagnetti
SCSerge Sébastien Colson
Serge Sébastien Colson
Wearable sensors have recently been used to evaluate biomechanical parameters of everyday movements, but few have been located at the head level. This study investigated the relative and absolute reliability (intra- and inter-session) and concurrent validity of an inertial measurement unit (IMU) embedded in smart eyeglasses during sit-to-stand (STS) movements for the measurement of maximal acceleration of the head. Reliability and concurrent validity were investigated in nineteen young and healthy participants by comparing the acceleration values of the glasses’ IMU to an optoelectronic system. Sit-to-stand movements were performed in laboratory conditions using standardized tests. Participants wore the smart glasses and completed two testing sessions with STS movements performed at two speeds (slow and comfortable) under two different conditions (with and without a cervical collar). Both the vertical and anteroposterior acceleration values were collected and analyzed. The use of the cervical collar did not significantly influence the results obtained. The relative reliability intra- and inter-session was good to excellent (i.e., intraclass correlation coefficients were between 0.78 and 0.91) and excellent absolute reliability (i.e., standard error of the measurement lower than 10% of the average test or retest value) was observed for the glasses, especially for the vertical axis. Whatever the testing sessions in all conditions, significant correlations (p < 0.001) were found for the acceleration values recorded either in the vertical axis and in the anteroposterior axis between the glasses and the optoelectronic system. Concurrent validity between the glasses and the optoelectronic system was observed. Our observations indicate that the IMU embedded in smart glasses is accurate to measure vertical acceleration during STS movements. Further studies should investigate the use of these smart glasses to assess the STS movement in unstandardized settings (i.e., clinical and/or home) and to report vertical acceleration values in an elderly population of fallers and non-fallers.

4 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JHJustine Hellec
Justine Hellec
FCFREDERIC CHORIN
FREDERIC CHORIN
ACAndrea Castagnetti
Andrea Castagnetti
OGOlivier Guérin
Olivier Guérin
SCSerge Sébastien Colson
Serge Sébastien Colson
The study aims to determine the validity and reproducibility of step duration and step length parameters measured during walking in healthy participants using an accelerometer embedded in smart eyeglasses. Twenty young volunteers participated in two identical sessions comprising a 30 s gait assessment performed at three different treadmill speeds under two conditions (i.e., with and without a cervical collar). Spatiotemporal parameters (i.e., step duration and step length normalized by the lower limb length) were obtained with both the accelerometer embedded in smart eyeglasses and an optoelectronic system. The relative intra- and inter-session reliability of step duration and step length computed from the vertical acceleration data were excellent for all experimental conditions. An excellent absolute reliability was observed for the eyeglasses for all conditions and concurrent validity between systems was observed. An accelerometer incorporated in smart eyeglasses is accurate to measure step duration and step length during gait.

3 August 2024 in European Geriatric Medicine
Verified
Journal Article
Open access
PDF file
EMEmeline MICHEL
Emeline MICHEL
RZRaphael Zory
Raphael Zory
OGOlivier Guerin
Olivier Guerin
FPFrederic Prate
Frederic Prate
GSGuillaume Sacco
Guillaume Sacco
FCFREDERIC CHORIN
FREDERIC CHORIN
Background: Falling is an important public health issue because of its prevalence and severe consequences. Evaluating muscle performance is important when assessing fall risk. The study aimed to identify factors [namely muscle capacity (strength, quality, and power) and spatio-temporal gait attributes] that best discriminate between fallers and non-fallers in older adults. The hypothesis is that muscle quality, defined as the ratio of muscle strength to muscle mass, is the best predictor of fall risk. Methods: 184 patients were included, 81% (n = 150) were women and the mean age was 73.6 ± 6.83 years. We compared body composition, mean grip strength, spatio-temporal parameters, and muscle capacity of fallers and non-fallers. Muscle quality was calculated as the ratio of maximum strength to fat-free mass. Mean handgrip and power were also controlled by fat-free mass. We performed univariate analysis, logistic regression, and ROC curves. Results: The falling patients had lower muscle quality, muscle mass-controlled power, and mean weighted handgrip than the non-faller. Results showing that lower muscle quality increases fall risk (effect size = 0.891). Logistic regression confirmed muscle quality as a significant predictor (p < .001, OR = 0.82, CI [0.74; 0.89]). ROC curves demonstrated muscle quality as the most predictive factor of falling (AUC = 0.794). Conclusion: This retrospective study showed that muscle quality is the best predictor of fall risk, above spatial and temporal gait parameters. Our results underscore muscle quality as a clinically meaningful assessment and may be a useful complement to other assessments for fall prevention in the aging population.

6 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NRNicolas Reneaud
Nicolas Reneaud
RZRaphaël Zory
Raphaël Zory
OGOlivier Guérin
Olivier Guérin
LTLuc Thomas
Luc Thomas
SCSerge Sébastien Colson
Serge Sébastien Colson
FCFREDERIC CHORIN
FREDERIC CHORIN
To test a novel instrumented knee brace intended for use as a rehabilitation system, based on inertial measurement units (IMU) to monitor home-based exercises, the device was compared to the gold standard of motion analysis. The purpose was to validate a new calibration method through functional tasks and assessed the value of adding magnetometers for motion analysis. Thirteen healthy young adults performed a 60-second gait test at a comfortable walking speed on a treadmill. Knee kinematics were captured simultaneously, using the instrumented knee brace and an optoelectronic camera system (OCS). The intraclass correlation coefficient (ICC) showed excellent reliability for the three axes of rotation with and without magnetometers, with values ranging between 0.900 and 0.972. Pearson’s r coefficient showed good to excellent correlation for the three axes, with the root mean square error (RMSE) under 3° with the IMUs and slightly higher with the magnetometers. The instrumented knee brace obtained certain clinical parameters, as did the OCS. The instrumented knee brace seems to be a valid tool to assess ambulatory knee kinematics, with an RMSE of <3°, which is sufficient for clinical interpretations. Indeed, this portable system can obtain certain clinical parameters just as well as the gold standard of motion analysis. However, the addition of magnetometers showed no significant advantage in terms of enhancing accuracy.