Serge Sébastien Colson

Prof. Serge Sébastien Colson

Université Côte d'Azur
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ADAude-Clémence M. Doix
Aude-Clémence M. Doix
FLFabrice Lefèvre
Fabrice Lefèvre
SCSerge Sébastien Colson
Serge Sébastien Colson
We investigated the cross-over effect of muscle fatigue and its time course on the non-exercising contralateral limb (NEL) after unilateral fatiguing contractions of the ipsilateral exercising limb (EL). For this purpose, 15 males performed two bouts of 100-second maximal isometric knee extensions with the exercising limb, and neuromuscular function of both the EL and NEL was assessed before (PRE), after a first fatiguing exercise (MID) and after a second fatiguing exercise (POST). Maximal voluntary isometric torque production declined in the EL after the first bout of exercise (−9.6%; p<0.001) while in the NEL, the decrease occurred after the second bout of exercise (−10.6%; p<0.001). At MID, torque decline of the EL was strictly associated to an alteration of the mechanical twitch properties evoked by neurostimulation of the femoral nerve (i.e., peak twitch torque, maximal rate of twitch development). According to these markers, we suggest that peripheral fatigue occurred. At POST, after the second bout of exercise, the voluntary activation level of the knee extensor muscles was altered from PRE (−9.1%; p<0.001), indicating an overall central failure in both the EL and NEL. These findings indicate that two bouts of unilateral fatiguing exercise were needed to induce a cross-over effect of muscle fatigue on the non-exercising contralateral limb. Differential adjustments of the motor pathway (peripheral fatigue vs. central fatigue) might contribute to the respective torque decline in the EL and the NEL. Given that our unilateral fatiguing exercise induced immediate maximal torque reduction in the EL and postponed the loss of torque production in the NEL, it is also concluded that the time course of muscle fatigue differed between limbs.

1 April 2010 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
SCSerge Sébastien Colson
Serge Sébastien Colson
MPManuela Pensini
Manuela Pensini
JEJulien Espinosa
Julien Espinosa
FGFrederic Garrandes
Frederic Garrandes
PLPatrick Legros
Patrick Legros
The aim of this study was to investigate the influence of 4 weeks of whole-body vibration training added to the conventional training of basketball players. Eighteen competitive basketball players (13 male symbol, 5 female symbol, 18-24 years old) were randomly assigned to a whole-body vibration group (WBVG, n = 10; 7 male symbol and 3 female symbol) or a control group (CG, n = 8; 6 male symbol and 2 female symbol). During the 4-week period, all subjects maintained their conventional basketball training program. The members of WBVG were additionally trained 3 times a week for 20 minutes on a vibration platform (10 unloaded static lower limb exercises, 40-Hz, 4-mm, Silverplate). Testing was performed before and after the 4-week period and comprised strength assessment, vertical jump performance, and a 10-m sprint test. The maximal voluntary isometric strength of the knee extensors significantly increased (p < 0.001) after vibration training, as did squat jump (SJ) height (p < 0.05), whereas performance of the countermovement jump, drop jump, 30-second rebound jump, and 10-m sprint remained unchanged. The results of the present study indicated that a 4-week whole-body vibration training program added to the conventional training of basketball players during the preseason is an effective short-term stimulus to enhance knee extensor strength and slightly SJ performance.

1 October 2009 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
SCSerge Sébastien Colson
Serge Sébastien Colson
AMAlain Martin
Alain Martin
JHJacques Van Hoecke
Jacques Van Hoecke

1 January 2017 in International Journal of Sports Physiology and Performance
Verified
Journal Article
Closed access
FVFabrice Vercruyssen
Fabrice Vercruyssen
MGMathieu Gruet
Mathieu Gruet
SCSerge Sébastien Colson
Serge Sébastien Colson
SESabine Ehrstrom
Sabine Ehrstrom
JBJeanick Brisswalter
Jeanick Brisswalter
Background:: Physiological mechanisms behind the use of compression garments (CGs) during off-road running are unknown.Purpose:: To investigate the influence of wearing CGs vs conventional running clothing (CON) on muscle contractile function and running economy before and after short-distance trail running.Methods:: Knee-extensor neuromuscular function and running economy assessed from two 5-min treadmill runs (11 and 14 km/h) were evaluated before and after an 18.6-km short-distance trail run in 12 trained athletes wearing either CGs (stocking + short-tight) or CON. Quadriceps neuromuscular function was assessed from mechanical and EMG recording after maximal percutaneous electrical femoral-nerve stimulations (single-twitch doublets at 10 [Db10] and 100 Hz [Db100] delivered at rest and during maximal quadriceps voluntary contraction [MVC]).Results:: Running economy (in mL O2 · km–1 · kg–1) increased after trail running independent of the clothing condition and treadmill speeds (P < .001). Similarly, MVC decreased after CON and CGs conditions (–11% and –13%, respectively, P < .001). For both clothing conditions, a significant decrease in quadriceps voluntary activation, Db10, Db100, and the low-to-high frequency doublet ratio were observed after trail running (time effect, all P < .01), without any changes in rectus femoris maximal M-wave.Conclusions:: Wearing CGs does not reduce physiological alterations induced during short-distance trail running. Further studies should determine whether higher intensity of compression pressure during exercises of longer duration may be effective to induce any physiological benefits in experienced trail runners.

4 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JHJustine Hellec
Justine Hellec
FCFREDERIC CHORIN
FREDERIC CHORIN
ACAndrea Castagnetti
Andrea Castagnetti
SCSerge Sébastien Colson
Serge Sébastien Colson
Wearable sensors have recently been used to evaluate biomechanical parameters of everyday movements, but few have been located at the head level. This study investigated the relative and absolute reliability (intra- and inter-session) and concurrent validity of an inertial measurement unit (IMU) embedded in smart eyeglasses during sit-to-stand (STS) movements for the measurement of maximal acceleration of the head. Reliability and concurrent validity were investigated in nineteen young and healthy participants by comparing the acceleration values of the glasses’ IMU to an optoelectronic system. Sit-to-stand movements were performed in laboratory conditions using standardized tests. Participants wore the smart glasses and completed two testing sessions with STS movements performed at two speeds (slow and comfortable) under two different conditions (with and without a cervical collar). Both the vertical and anteroposterior acceleration values were collected and analyzed. The use of the cervical collar did not significantly influence the results obtained. The relative reliability intra- and inter-session was good to excellent (i.e., intraclass correlation coefficients were between 0.78 and 0.91) and excellent absolute reliability (i.e., standard error of the measurement lower than 10% of the average test or retest value) was observed for the glasses, especially for the vertical axis. Whatever the testing sessions in all conditions, significant correlations (p < 0.001) were found for the acceleration values recorded either in the vertical axis and in the anteroposterior axis between the glasses and the optoelectronic system. Concurrent validity between the glasses and the optoelectronic system was observed. Our observations indicate that the IMU embedded in smart glasses is accurate to measure vertical acceleration during STS movements. Further studies should investigate the use of these smart glasses to assess the STS movement in unstandardized settings (i.e., clinical and/or home) and to report vertical acceleration values in an elderly population of fallers and non-fallers.

5 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MDMathis D'Haene
Mathis D'Haene
FCFREDERIC CHORIN
FREDERIC CHORIN
SCSerge Sébastien Colson
Serge Sébastien Colson
OGOlivier Guérin
Olivier Guérin
RZRaphaël Zory
Raphaël Zory
EPElodie Piche
Elodie Piche
Gait analysis is essential for evaluating walking patterns and identifying functional limitations. Traditional marker-based motion capture tools are costly, time-consuming, and require skilled operators. This study evaluated a 3D Marker-less Motion Capture (3D MMC) system using pose and depth estimations with the gold-standard Motion Capture (MOCAP) system for measuring hip and knee joint angles during gait at three speeds (0.7, 1.0, 1.3 m/s). Fifteen healthy participants performed gait tasks which were captured by both systems. The 3D MMC system demonstrated good accuracy (LCC > 0.96) and excellent inter-session reliability (RMSE < 3°). However, moderate-to-high accuracy with constant biases was observed during specific gait events, due to differences in sample rates and kinematic methods. Limitations include the use of only healthy participants and limited key points in the pose estimation model. The 3D MMC system shows potential as a reliable tool for gait analysis, offering enhanced usability for clinical and research applications.