Chiara Toffanin

Prof. Chiara Toffanin

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2012 in Diabetes
Verified
Journal Article
Open access
PDF file
MBMarc Breton
Marc Breton
AFAnne Farret
Anne Farret
DBDaniela Bruttomesso
Daniela Bruttomesso
SAStacey Anderson
Stacey Anderson
LMLalo Magni
Lalo Magni
OGon behalf of The International Artificial Pancreas (iAP) Study Group
on behalf of The International Artificial Pancreas (iAP) Study Group
Integrated closed-loop control (CLC), combining continuous glucose monitoring (CGM) with insulin pump (continuous subcutaneous insulin infusion [CSII]), known as artificial pancreas, can help optimize glycemic control in diabetes. We present a fundamental modular concept for CLC design, illustrated by clinical studies involving 11 adolescents and 27 adults at the Universities of Virginia, Padova, and Montpellier. We tested two modular CLC constructs: standard control to range (sCTR), designed to augment pump plus CGM by preventing extreme glucose excursions; and enhanced control to range (eCTR), designed to truly optimize control within near normoglycemia of 3.9–10 mmol/L. The CLC system was fully integrated using automated data transfer CGM→algorithm→CSII. All studies used randomized crossover design comparing CSII versus CLC during identical 22-h hospitalizations including meals, overnight rest, and 30-min exercise. sCTR increased significantly the time in near normoglycemia from 61 to 74%, simultaneously reducing hypoglycemia 2.7-fold. eCTR improved mean blood glucose from 7.73 to 6.68 mmol/L without increasing hypoglycemia, achieved 97% in near normoglycemia and 77% in tight glycemic control, and reduced variability overnight. In conclusion, sCTR and eCTR represent sequential steps toward automated CLC, preventing extremes (sCTR) and further optimizing control (eCTR). This approach inspires compelling new concepts: modular assembly, sequential deployment, testing, and clinical acceptance of custom-built CLC systems tailored to individual patient needs.

1 December 2015 in The Lancet Diabetes & Endocrinology
Verified
Journal Article
Closed access
JKJort Kropff
Jort Kropff
SFSimone Del Favero
Simone Del Favero
JPJerome Place
Jerome Place
CTChiara Toffanin
Chiara Toffanin
Roberto VisentinRoberto Visentin
Roberto Visentin
LMLalo Magni
Lalo Magni

1 November 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SPS. D. Patek
S. D. Patek
LMLalo Magni
Lalo Magni
EDE. Dassau
E. Dassau
CHC. Hughes-Karvetski
C. Hughes-Karvetski
CTChiara Toffanin
Chiara Toffanin
BKB. P. Kovatchev
B. P. Kovatchev
Modularity plays a key role in many engineering systems, allowing for plug-and-play integration of components, enhancing flexibility and adaptability, and facilitating standardization. In the control of diabetes, i.e., the so-called “artificial pancreas,” modularity allows for the step-wise introduction of (and regulatory approval for) algorithmic components, starting with subsystems for assured patient safety and followed by higher layer components that serve to modify the patient's basal rate in real time. In this paper, we introduce a three-layer modular architecture for the control of diabetes, consisting in a sensor/pump interface module (IM), a continuous safety module (CSM), and a real-time control module (RTCM), which separates the functions of insulin recommendation (postmeal insulin for mitigating hyperglycemia) and safety (prevention of hypoglycemia). In addition, we provide details of instances of all three layers of the architecture: the APS© serving as the IM, the safety supervision module (SSM) serving as the CSM, and the range correction module (RCM) serving as the RTCM. We evaluate the performance of the integrated system via in silico preclinical trials, demonstrating 1) the ability of the SSM to reduce the incidence of hypoglycemia under nonideal operating conditions and 2) the ability of the RCM to reduce glycemic variability.

12 June 2014 in Diabetes Care
Verified
Journal Article
Open access
PDF file
BKBoris P. Kovatchev
Boris P. Kovatchev
EREric Renard
Eric Renard
CCClaudio Cobelli
Claudio Cobelli
HZHoward C. Zisser
Howard C. Zisser
PKPatrick Keith-Hynes
Patrick Keith-Hynes
FDFrancis J. Doyle
Francis J. Doyle
OBJECTIVE We estimate the effect size of hypoglycemia risk reduction on closed-loop control (CLC) versus open-loop (OL) sensor-augmented insulin pump therapy in supervised outpatient setting. RESEARCH DESIGN AND METHODS Twenty patients with type 1 diabetes initiated the study at the Universities of Virginia, Padova, and Montpellier and Sansum Diabetes Research Institute; 18 completed the entire protocol. Each patient participated in two 40-h outpatient sessions, CLC versus OL, in randomized order. Sensor (Dexcom G4) and insulin pump (Tandem t:slim) were connected to Diabetes Assistant (DiAs)—a smartphone artificial pancreas platform. The patient operated the system through the DiAs user interface during both CLC and OL; study personnel supervised on site and monitored DiAs remotely. There were no dietary restrictions; 45-min walks in town and restaurant dinners were included in both CLC and OL; alcohol was permitted. RESULTS The primary outcome—reduction in risk for hypoglycemia as measured by the low blood glucose (BG) index (LGBI)—resulted in an effect size of 0.64, P = 0.003, with a twofold reduction of hypoglycemia requiring carbohydrate treatment: 1.2 vs. 2.4 episodes/session on CLC versus OL (P = 0.02). This was accompanied by a slight decrease in percentage of time in the target range of 3.9–10 mmol/L (66.1 vs. 70.7%) and increase in mean BG (8.9 vs. 8.4 mmol/L; P = 0.04) on CLC versus OL. CONCLUSIONS CLC running on a smartphone (DiAs) in outpatient conditions reduced hypoglycemia and hypoglycemia treatments when compared with sensor-augmented pump therapy. This was accompanied by marginal increase in average glycemia resulting from a possible overemphasis on hypoglycemia safety.

1 April 2012 in Annual Reviews in Control
Verified
Journal Article
Closed access
PSP. Soru
P. Soru
GNG. De Nicolao
G. De Nicolao
CTChiara Toffanin
Chiara Toffanin
Chiara Dalla ManChiara Dalla Man
Chiara Dalla Man
CCC. Cobelli
C. Cobelli
LMLalo Magni
Lalo Magni

11 January 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CTChiara Toffanin
Chiara Toffanin
Roberto VisentinRoberto Visentin
Roberto Visentin
MMMirko Messori
Mirko Messori
FPFederico Di Palma
Federico Di Palma
LMLalo Magni
Lalo Magni
CCClaudio Cobelli
Claudio Cobelli
Objective: Contemporary and future outpatient long-term artificial pancreas (AP) studies need to cope with the well-known large intra- and interday glucose variability occurring in type 1 diabetic (T1D) subjects. Here, we propose an adaptive model predictive control (MPC) strategy to account for it and test it in silico. Methods: A run-to-run (R2R) approach adapts the subcutaneous basal insulin delivery during the night and the carbohydrate-to-insulin ratio (CR) during the day, based on some performance indices calculated from subcutaneous continuous glucose sensor data. In particular, R2R aims, first, to reduce the percentage of time in hypoglycemia and, secondarily, to improve the percentage of time in euglycemia and average glucose. In silico simulations are performed by using the University of Virginia/Padova T1D simulator enriched by incorporating three novel features: intra- and interday variability of insulin sensitivity, different distributions of CR at breakfast, lunch, and dinner, and dawn phenomenon. Results: After about two months, using the R2R approach with a scenario characterized by a random ±30% variation of the nominal insulin sensitivity the time in range and the time in tight range are increased by 11.39% and 44.87%, respectively, and the time spent above 180 mg/dl is reduced by 48.74%. Conclusions : An adaptive MPC algorithm based on R2R shows in silico great potential to capture intra- and interday glucose variability by improving both overnight and postprandial glucose control without increasing hypoglycemia. Significance: Making an AP adaptive is key for long-term real-life outpatient studies. These good in silico results are very encouraging and worth testing in vivo.