Jort Kropff

Jort Kropff

Auto-generated profile, based on publicly available information

Jort Kropff

Department of Endocrinology, Academic Medical Centre, University of Amsterdam, Amsterdam, The Netherlands

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in The Lancet Diabetes & Endocrinology
Verified
Journal Article
Closed access
JKJort Kropff
Jort Kropff
SFSimone Del Favero
Simone Del Favero
JPJerome Place
Jerome Place
CTChiara Toffanin
Chiara Toffanin
Roberto VisentinRoberto Visentin
Roberto Visentin
LMLalo Magni
Lalo Magni

4 November 2016 in Diabetes Care
Verified
Journal Article
Open access
PDF file
JKJort Kropff
Jort Kropff
PCPratik Choudhary
Pratik Choudhary
SNSankalpa Neupane
Sankalpa Neupane
KBKatharine Barnard
Katharine Barnard
SBSteve C. Bain
Steve C. Bain
JDJ. Hans DeVries
J. Hans DeVries
OBJECTIVE: It is known that continuous glucose monitoring (CGM) systems can lower mean glucose compared with episodic self-monitoring of blood glucose. Implantable CGM systems may provide additional benefits. RESEARCH DESIGN AND METHODS: We studied the Eversense (Senseonics Inc.) implantable CGM sensor in 71 participants aged 18 years and older with type 1 and type 2 diabetes in a 180-day multinational, multicenter pivotal trial. Participants used the CGM system at home and in the clinic. CGM accuracy was assessed during eight in-clinic visits with the mean absolute relative difference (MARD) for venous reference glucose values >4.2 mmol/L as the primary end point. Secondary end points included Clarke Error Grid Analysis and alarm performance. The primary safety outcome was device-related serious adverse events. This trial is registered with ClinicalTrials.gov, number NCT02154126. RESULTS: The MARD value against reference glucose values >4.2 mmol/L was 11.1% (95% CI 10.5, 11.7). Clarke Error Grid Analysis showed 99.2% of samples in the clinically acceptable error zones A and B. Eighty-one percent of hypoglycemic events were detected by the CGM system within 30 min. No device-related serious adverse events occurred during the study. CONCLUSIONS: Our results indicate the safety and accuracy of this new type of implantable CGM system and support it as an alternative for transcutaneous CGM.

11 August 2014 in Diabetes, Obesity and Metabolism
Verified
Journal Article
Open access
PDF file
JKJ. Kropff
J. Kropff
DBD. Bruttomesso
D. Bruttomesso
WDW. Doll
W. Doll
AFA. Farret
A. Farret
SGS. Galasso
S. Galasso
JDJ. H. DeVries
J. H. DeVries
Aims: To assess the accuracy and reliability of the two most widely used continuous glucose monitoring ( CGM ) systems. Methods: We studied the Dexcom® G4 Platinum ( DG4P ; Dexcom, San Diego, CA , USA ) and Medtronic Paradigm Veo Enlite system ( ENL ; Medtronic, Northridge, CA , USA ) CGM systems, in 24 patients with type 1 diabetes. The CGM systems were tested during 6‐day home use and a nested 6‐h clinical research centre ( CRC ) visit. During the CRC visit, frequent venous blood glucose samples were used as reference while patients received a meal with an increased insulin bolus to induce an aggravated postprandial glucose nadir. At home, patients performed at least six reference capillary blood measurements per day. A Wilcoxon signed‐rank test was performed using all data points ≥15 min apart. Results: The overall mean absolute relative difference ( MARD ) value [standard deviation (s.d.)] measured at the CRC was 13.6 (11.0)% for the DG4P and 16.6 (13.5)% for the ENL [p < 0.0002, confidence interval of difference ( CI Δ) 1.7–4.3%, n = 530]. The overall MARD assessed at home was 12.2 (12.0)% for the DG4P and 19.9 (20.5)% for the ENL (p < 0.0001, CI Δ = 5.8–8.7%, n = 839). During the CRC visit, the MARD in the hypoglycaemic range [≤3.9 mmol/l (70 mg/dl)], was 17.6 (12.2)% for the DG4P and 24.6 (18.8)% for the ENL (p = 0.005, CI Δ 3.1–10.7%, n = 117). Both sensors showed higher MARD values during hypoglycaemia than during euglycaemia [3.9–10 mmol/l (70–180 mg/dl)]: for the DG4P 17.6 versus 13.0% and for the ENL 24.6 versus 14.2%. Conclusions: During circumstances of intended use, including both a CRC and home phase, the ENL was noticeably less accurate than the DG4P sensor. Both sensors showed lower accuracy in the hypoglycaemic range. The DG4P was less affected by this negative effect of hypoglycaemia on sensor accuracy than was the ENL .

1 February 2016 in Diabetes Technology & Therapeutics
Verified
Journal Article
Open access
JKJort Kropff
Jort Kropff
JDJ. Hans DeVries
J. Hans DeVries
The development of accurate and easy-to-use continuous glucose monitoring (CGM) improved diabetes treatment by providing additional temporal information on glycemia and glucose trends to patient and physician. Although CGM enables users to lower their average glucose level without an increased incidence of hypoglycemia, this comes at the price of additional patient effort. Automation of insulin administration, also known as closed-loop (CL) or artificial pancreas treatment, has the promise to reduce patient effort and improve glycemic control. CGM data serve as the conditional input for insulin automation devices. The first commercial product for partial automation of insulin administration used insulin delivery shutoff at a predefined glucose level. These systems showed a reduction in hypoglycemia. Insulin-only CL devices show increased time spent in euglycemia and a reduction of hypo- and hyperglycemia. Improved glycemic control, coinciding with a minor decrease in hemoglobin A1c level, was confirmed in recent long-term home studies investigating these devices, paving the way for pivotal studies for commercialization of the artificial pancreas. Although the first results from dual-hormone CL systems are promising, because of increased cost of consumables of these systems, long-term head-to-head studies will have to prove superiority over insulin-only approaches. Now CL glucose control for daily use might finally become reality. Improved continuous glucose sensing technology, miniaturization of electrical devices, and development of algorithms were key in making this possible. Clinical adoption challenges, including device usability and reimbursement, need to be addressed. Time will tell for which patient groups CL systems will be reimbursed and whether these devices can deliver the promise that they hold.

1 October 2016 in Diabetic Medicine
Verified
Journal Article
Open access
PDF file
JKJ. Kropff
J. Kropff
JDJ. DeJong
J. DeJong
SFS. del Favero
S. del Favero
JPJ. Place
J. Place
MMM. Messori
M. Messori
TCThe Ap@Home Consortium
The Ap@Home Consortium
Aim: To assess the impact on fear of hypoglycaemia and treatment satisfaction with an artificial pancreas system used for 2 consecutive months, as well as participant acceptance of the artificial pancreas system.Methods: In a randomized crossover trial patient‐related outcomes associated with an evening‐and‐night artificial pancreas and sensor‐augmented pump therapy were compared. Both intervention periods lasted 8 weeks. The artificial pancreas acceptance questionnaire (range 0–90, higher scores better), Hypoglycaemia Fear Survey II (range 0–72, higher scores worse) and Diabetes Treatment Satisfaction Questionnaire (range 0–36, higher scores better) were completed by 32 participants. Semi‐structured interviews were conducted after study completion in a subset of six participants. Outcomes were compared using a repeated‐measures anova model or paired t‐test when appropriate.Results: The total artificial pancreas acceptance questionnaire score at the end of the artificial pancreas period was 69.1 (sd 14.7; 95% CI 63.5, 74.7), indicating a positive attitude towards the artificial pancreas. No significant differences were found among the scores at baseline, end of sensor‐augmented pump therapy period or end of the artificial pancreas period with regard to fear of hypoglycaemia [28.2 (sd 17.5), 23.5 (sd 16.6) and 23.5 (sd 16.7), respectively; P = 0.099] or diabetes treatment satisfaction [29.0 (sd 3.9), 28.2 (sd 5.2) and 28.0 (sd 7.1), respectively; P = 0.43]. Themes frequently mentioned in the interviews were ‘positive effects at work’, ‘improved blood glucose’, ‘fewer worries about blood glucose’, but also ‘frequent alarms’, ‘technological issues’ and ‘demand for an all‐in‐one device’.Conclusions: The psychological outcomes of artificial pancreas and sensor‐augmented pump therapy were similar. Current artificial pancreas technology is promising but user concerns should be taken into account to ensure utility of these systems.