Romain Guider

Dr. Romain Guider


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2016 in Biosensors
Verified
Journal Article
Open access
PDF file
Tatevik ChalyanTatevik Chalyan
Tatevik Chalyan
RGRomain Guider
Romain Guider
LPLaura Pasquardini
Laura Pasquardini
MZManuela Zanetti
Manuela Zanetti
FFFloris Falke
Floris Falke
Lorenzo PavesiLorenzo Pavesi
Lorenzo Pavesi
In this work, we present a study of Aflatoxin M1 detection by photonic biosensors based on Si3N4 Asymmetric Mach–Zehnder Interferometer (aMZI) functionalized with antibodies fragments (Fab′). We measured a best volumetric sensitivity of 104 rad/RIU, leading to a Limit of Detection below 5 × 10−7 RIU. On sensors functionalized with Fab′, we performed specific and non-specific sensing measurements at various toxin concentrations. Reproducibility of the measurements and re-usability of the sensor were also investigated.

16 July 2015 in Sensors
Verified
Journal Article
Open access
PDF file
RGRomain Guider
Romain Guider
DGDavide Gandolfi
Davide Gandolfi
Tatevik ChalyanTatevik Chalyan
Tatevik Chalyan
LPLaura Pasquardini
Laura Pasquardini
ASAlina Samusenko
Alina Samusenko
Lorenzo PavesiLorenzo Pavesi
Lorenzo Pavesi
In this article, we designed and studied silicon oxynitride (SiON) microring-based photonic structures for biosensing applications. We designed waveguides, directional couplers, and racetrack resonators in order to measure refractive index changes smaller than 10−6 refractive index units (RIU). We tested various samples with different SiON refractive indexes as well as the waveguide dimensions for selecting the sensor with the best performance. Propagation losses and bending losses have been measured on test structures, along with a complete characterization of the resonator’s performances. Sensitivities and limit of detection (LOD) were also measured using glucose-water solutions and compared with expected results from simulations. Finally, we functionalized the resonator and performed sensing experiments with Aflatoxin M1 (AFM1). We were able to detect the binding of aflatoxin for concentrations as low as 12.5 nm. The results open up the path for designing cost-effective biosensors for a fast and reliable sensitive analysis of AFM1 in milk.

4 September 2015 in Optical Materials Express
Verified
Journal Article
Open access
PDF file
RGRomain Guider
Romain Guider
CTCristina Traversa
Cristina Traversa
PBPaolo Bettotti
Paolo Bettotti
In this work, we report on the difference of mechanical stress in free standing and attached Porous silicon membranes. By performing Raman analysis, we demonstrate that the tensile stress accumulated during the etching process by the porous silicon layer is partially compensated by the presence of the substrate. We highlight this complex effect by experimentally showing the balancing effect of the substrate and the change in mechanical stress between top and bottom surfaces in free standing membranes. In addition, this Raman investigation allows us to separate the effects on the Raman lineshape due to the nanostructures from those related with the mechanical stress of macroscopic structures.