The objective of this in vivo study was to compare bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) values of a new implant, designed to be inserted without bone preparation, using two different preparation protocols: no site preparation and prior limited cortical perforation, versus the values of a control implant using a conventional drilling protocol. Forty-one implants were inserted in 13 rabbits. Thirteen test implants with a new thread design were inserted using no bone preparation (NP), 14 test implants were inserted with limited cortical perforation (CP), and 14 conventional implants served as control. Five animals were sacrificed after 21 days and eight animals after 42 days. Histomorphometric analysis was performed and percentage of BIC and BAFO values were measured. ANOVA with Tukey post hoc and Mann–Whitney nonparametric tests were calculated to compare between the groups. Statistical analysis showed no significant difference in the measured values between any of the groups, neither compered by implant nor by compered day. The results demonstrated that biological osseointegration parameters of implant that was inserted without any bone preparation was non-inferior compared to conventional preparation. The clinical relevance is that novel implant designs may not require bone preparation prior to placement.
A wide variety of titanium (Ti) alloy dental implant systems are available and as a result, choosing the correct system has become a challenge. Cleanliness of the dental implant surface affects osseointegration but surface cleanliness may be jeopardized during manufacturing. The purpose of this study was to assess the cleanliness of three implant systems. Fifteen implants per system were examined with scanning electron microscopy to identify and count foreign particles. Particle chemical composition analysis was performed with energy-dispersive X-ray spectroscopy. Particles were categorized according to size and location. Particles on the outer and inner threads were quantitatively compared. A second scan was performed after exposing the implants to room air for 10 min. Carbon, among other elements, was found on the surface of all implant groups. Zimmer Biomet dental implants had higher particle numbers than other brands. Cortex and Keystone dental implants showed similar distribution patterns. The outer surface had higher particle numbers. Cortex dental implants were the cleanest. The change in particle numbers after exposure was not significant (p > 0.05). Conclusion: Most of the implants studied were contaminated. Particle distribution patterns vary with the manufacturer. The wider and outer areas of the implant have a higher probability of contamination.
1 March 2021 in The International Journal of Oral and Maxillofacial Implants
Purpose: The objective of this study was to report implant survival rates, marginal bone loss, and the impact of prosthesis type among patients with type 2 diabetes mellitus (DMT2), with high hemoglobin A1C (HbA1c) values. Materials and Methods: This retrospective study utilized patient medical records from an oral surgeon's office. Patients who had moderately or poorly controlled DMT2 with HbA1c values up to 10% were reviewed. Inclusion criteria were partially or fully edentulous patients diagnosed with DMT2 who were subsequently treated with implant-supported prosthetic restorations. Patients were at least 18 years of age. Exclusion criteria were patients who did not present for annual follow-up visits, patient records with incomplete surgical or restorative data, or nondiagnostic radiographs. All the fixed restorations were cement-retained, and the removable restorations were supported by two to six implants. Marginal bone loss and the consequences of prosthetic type were assessed from the last available radiograph compared with the one taken after the surgical procedure. Results: Data of 357 implants were extracted from the records of 38 patients with HbA1c values (6.9% to 10.0%). The mean follow-up was 7.3 years, with a minimum of 5 years. Six implants failed, yielding a 98.4% overall implant survival rate. The patients were divided into two groups according to the HbA1c values before implant placement. The moderately controlled group included 25 patients with DMT2, with HbA1c values of 6.9% to 8.0%, and the poorly controlled group included 13 patients, with HbA1c values of 8.1% to 10.0%. The overall mean bone loss was 2.02 +/- 2.43 mm. In both groups, the maxilla demonstrated more bone loss than the mandible (P<.05). Marginal bone loss in moderately controlled and poorly controlled groups was 1.86 (+/- 2.21) mm and 2.33 (+/- 2.85) mm, respectively (P<.05). Removable prostheses also revealed greater bone loss rates compared with fixed prostheses in both groups (P<.05). Conclusion: Patients with high HbA1c values (8.1% to 10.0%) had more marginal bone loss than those with lower HbA1c values. Removable dentures should be reconsidered as a standard treatment option in these patients.
Purpose: To estimate the effects of the thermal cycling (TC) process on the metal surfaces of Locators, as well as retention loss, and the correlation between them.Materials and methods: Twenty‐five new Locator R‐Tx were included in the study. Four areas were marked on each Locators’ patrix metal surface and scanned using a confocal scanner (μsurf explorer; NanoFocus). Three surface roughness parameters were measured in the scans: Sa (average distance of peaks from the central plain of the area), Vmp (volume of the peaks in the area), and Spc (mean curvature of the peaks describing the degree of their sharpness). Retention test was performed using Instron® 4500 compression tension tensile tester at a speed of 10 mm/min. The retention tests were done using a working model made of two acrylic blocks in which the Locator system parts were inserted. The surface parameters measurements and the retention tests were performed 2 times, once before and once after TC. The Locators were subjected to 15,000 TC cycles by investing them into 2 tubs with different water temperatures, 55°C and 5°C. During each 60‐second cycle, the Locators were submerged in each tub for 20 seconds, with a 10 second transition time between the tubs. The post‐TC retention and surface parameters measurements were compared with those prior to TC and the prior to TC measurements served as controls. Changes in parameters before and after TC were analyzed by a two‐way ANOVA nested model with random intercept and slope by restricted maximum likelihood method. Correlation between retention and surface parameters was quantified and examined using Kendall's correlation test. The findings were considered statistically significant if p < 0.05.Results: There was a significant decrease in retention of 16.6N at the second retention test (p < 0.001). A significant statistical decrease in surface parameters were measured after TC process, Sa and Vmp (18 ×10–3 μm, p = 0.041 and 0.94 ×10–3 1/μm, p = 0.001, respectively). A significant statistical increase in Spc of 6.4 ×10–3 μm3/μm2 (p = 0.023) was noticed. The correlation between retention decreases and surface changes was not statistically significant.Conclusion: The TC process causes a substantial reduction in retention to the Locator system over time. In addition, TC causes significant but minor changes to the Locator surface area. Most of the changes are in the horizontal dimension.