Ameer Biadsee

Dr. Ameer Biadsee

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
TMTarek Mtanis
Tarek Mtanis
ABAmeer Biadsee
Ameer Biadsee
Zeev OrmianerZeev Ormianer
Zeev Ormianer
A wide variety of titanium (Ti) alloy dental implant systems are available and as a result, choosing the correct system has become a challenge. Cleanliness of the dental implant surface affects osseointegration but surface cleanliness may be jeopardized during manufacturing. The purpose of this study was to assess the cleanliness of three implant systems. Fifteen implants per system were examined with scanning electron microscopy to identify and count foreign particles. Particle chemical composition analysis was performed with energy-dispersive X-ray spectroscopy. Particles were categorized according to size and location. Particles on the outer and inner threads were quantitatively compared. A second scan was performed after exposing the implants to room air for 10 min. Carbon, among other elements, was found on the surface of all implant groups. Zimmer Biomet dental implants had higher particle numbers than other brands. Cortex and Keystone dental implants showed similar distribution patterns. The outer surface had higher particle numbers. Cortex dental implants were the cleanest. The change in particle numbers after exposure was not significant (p > 0.05). Conclusion: Most of the implants studied were contaminated. Particle distribution patterns vary with the manufacturer. The wider and outer areas of the implant have a higher probability of contamination.

4 January 2023 in The Korean Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
ABAmeer Biadsee
Ameer Biadsee
OROfir Rosner
Ofir Rosner
CKCarol Khalil
Carol Khalil
VAVanina Atanasova
Vanina Atanasova
JBJoel Blushtein
Joel Blushtein
SLShifra Levartovsky
Shifra Levartovsky
Ameer Biadsee, Ofir Rosner, Carol Khalil, Vanina Atanasova, Joel Blushtein, Shifra Levartovsky. Korean J Orthod -0001;0:. https://doi.org/10.4041/kjod22.098

21 January 2022 in Journal of Prosthodontics
Verified
Journal Article
Open access
PDF file
VPVladimir Perlis
Vladimir Perlis
TMTarek Mtanis
Tarek Mtanis
ABAmeer Biadsee
Ameer Biadsee
Zeev OrmianerZeev Ormianer
Zeev Ormianer
Purpose: To estimate the effects of the thermal cycling (TC) process on the metal surfaces of Locators, as well as retention loss, and the correlation between them.Materials and methods: Twenty‐five new Locator R‐Tx were included in the study. Four areas were marked on each Locators’ patrix metal surface and scanned using a confocal scanner (μsurf explorer; NanoFocus). Three surface roughness parameters were measured in the scans: Sa (average distance of peaks from the central plain of the area), Vmp (volume of the peaks in the area), and Spc (mean curvature of the peaks describing the degree of their sharpness). Retention test was performed using Instron® 4500 compression tension tensile tester at a speed of 10 mm/min. The retention tests were done using a working model made of two acrylic blocks in which the Locator system parts were inserted. The surface parameters measurements and the retention tests were performed 2 times, once before and once after TC. The Locators were subjected to 15,000 TC cycles by investing them into 2 tubs with different water temperatures, 55°C and 5°C. During each 60‐second cycle, the Locators were submerged in each tub for 20 seconds, with a 10 second transition time between the tubs. The post‐TC retention and surface parameters measurements were compared with those prior to TC and the prior to TC measurements served as controls. Changes in parameters before and after TC were analyzed by a two‐way ANOVA nested model with random intercept and slope by restricted maximum likelihood method. Correlation between retention and surface parameters was quantified and examined using Kendall's correlation test. The findings were considered statistically significant if p < 0.05.Results: There was a significant decrease in retention of 16.6N at the second retention test (p < 0.001). A significant statistical decrease in surface parameters were measured after TC process, Sa and Vmp (18 ×10–3 μm, p = 0.041 and 0.94 ×10–3 1/μm, p = 0.001, respectively). A significant statistical increase in Spc of 6.4 ×10–3 μm3/μm2 (p = 0.023) was noticed. The correlation between retention decreases and surface changes was not statistically significant.Conclusion: The TC process causes a substantial reduction in retention to the Locator system over time. In addition, TC causes significant but minor changes to the Locator surface area. Most of the changes are in the horizontal dimension.

16 July 2022 in Materials
Verified
Journal Article
Open access
PDF file
RKRiyam Jammal Kassem
Riyam Jammal Kassem
ASAmar Samara
Amar Samara
ABAmeer Biadsee
Ameer Biadsee
SMShchada Masarwa
Shchada Masarwa
TMTarek Mtanis
Tarek Mtanis
Zeev OrmianerZeev Ormianer
Zeev Ormianer
Background: The purpose of this study was to measure and compare the strain levels in the peri-implant bone as generated by the blade-like implant (BLI) and the screw-type implant (STI) with two different internal connections (hexagonal and conical) and with a 1:1 and 2:1 crown/implant (C/I) ratio. Methods: The implants (BLI and STI) were placed into sawbones according to the manufacturer’s protocol. Two strain gauges, horizontal and vertical to the implant axis, were placed around each implant on the bone surface 1 mm from the cervical part. Each implant was loaded by a material testing machine at a force of 100 N. Micro-strains (με) generated in the surrounding bone were measured by a strain gauge and recorded. Results: Recorded micro-strains were not significant in both the insertion and loading phases (p < 0.0625). The average recorded micro-strain values were lower in the horizontal dimension of STI with hexagonal connection when the C/I ratio was 2:1 compared with BLI, 210 με and 443 με, respectively. Conclusion: Within the limitations of this study, implant design, implant-abutment connection and C/I ratio did not influence strain values in bone and there is no statistically significant effect of these parameters on bone.

21 August 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
ABAmeer Biadsee
Ameer Biadsee
AKAyman Khalifa
Ayman Khalifa
TMTarek Mtanis
Tarek Mtanis
ZOZeev Ormianer
Zeev Ormianer

2 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
EDeran dolev
eran dolev
GBGil Ben-izhack
Gil Ben-izhack
AMAvi Meirowitz
Avi Meirowitz
HEHadar Erel
Hadar Erel
ORofir rosner
ofir rosner
ASasaf shely
asaf shely
Background: The purpose of the study was to evaluate the changes of light reflection% on two materials (monolithic zirconia and lithium disilicate) after using two external staining kits following by thermocycling. Methods: Specimens were sectioned from monolithic zirconia (n = 60) and lithium disilicate (n = 60) then divided into six groups (n = 20). Two different types of external staining kits were used and applied to the specimens. The light reflection% was measured before staining, after staining and after thermocycling using a spectrophotometer. Results: The light reflection% of zirconia was significantly higher compared to lithium disilicate at the beginning of the study (p = 0.005), after staining with kit 1 (p = 0.005) and kit 2 (p = 0.005) and after thermocycling (p = 0.005). For both materials, the light reflection% was lower after staining with Kit 1 compared to kit 2 (p < 0.043). After thermocycling, the light reflection% of lithium disilicate increased (p = 0.027) and was unchanged with Zirconia (p = 0.527). Conclusions: There is a difference between the materials regarding light reflection% as the monolithic zirconia showed higher light reflection% comparing lithium disilicate throughout the entire experiment. For lithium disilicate, we recommend using kit 1 as we found that, after thermocycling, the light reflection% of kit 2 was increased.