Rong-Chao Peng

Dr. Rong-Chao Peng

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
RPRong-Chao Peng
Rong-Chao Peng
XZXiao-Lin Zhou
Xiao-Lin Zhou
WLWan-Hua Lin
Wan-Hua Lin
YZYuan-Ting Zhang
Yuan-Ting Zhang
Heart rate variability (HRV) is a useful clinical tool for autonomic function assessment and cardiovascular diseases diagnosis. It is traditionally calculated from a dedicated medical electrocardiograph (ECG). In this paper, we demonstrate that HRV can also be extracted from photoplethysmograms (PPG) obtained by the camera of a smartphone. Sixteen HRV parameters, including time-domain, frequency-domain, and nonlinear parameters, were calculated from PPG captured by a smartphone for 30 healthy subjects and were compared with those derived from ECG. The statistical results showed that 14 parameters (AVNN, SDNN, CV, RMSSD, SDSD, TP, VLF, LF, HF, LF/HF, nLF, nHF, SD1, and SD2) from PPG were highly correlated (r>0.7,P<0.001) with those from ECG, and 7 parameters (AVNN, TP, VLF, LF, HF, nLF, and nHF) from PPG were in good agreement with those from ECG within the acceptable limits. In addition, five different algorithms to detect the characteristic points of PPG wave were also investigated: peak point (PP), valley point (VP), maximum first derivative (M1D), maximum second derivative (M2D), and tangent intersection (TI). The results showed that M2D and TI algorithms had the best performance. These results suggest that the smartphone might be used for HRV measurement.

8 May 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
MMMingdao Mu
Mingdao Mu
HGHong-Yan Geng
Hong-Yan Geng
KRKang-Lin Rong
Kang-Lin Rong
RPRong-Chao Peng
Rong-Chao Peng
SWShu-Ting Wang
Shu-Ting Wang
Y Ke Ya
Ke Ya
Prolonged exposure to negative stressors could be harmful if a subject cannot respond appropriately. Strategies evolved to respond to stress, including repetitive displacement behaviours, are important in maintaining behavioural homoeostasis. In rodents, self-grooming is a frequently observed repetitive behaviour believed to contribute to post-stress de-arousal with adaptive value. Here we identified a rat limbic di-synaptic circuit that regulates stress-induced self-grooming with positive affective valence. This circuit links hippocampal ventral subiculum to ventral lateral septum (LSv) and then lateral hypothalamus tuberal nucleus. Optogenetic activation of this circuit triggers delayed but robust excessive grooming with patterns closely resembling those evoked by emotional stress. Consistently, the neural activity of LSv reaches a peak before emotional stress-induced grooming while inhibition of this circuit significantly suppresses grooming triggered by emotional stress. Our results uncover a previously unknown limbic circuitry involved in regulating stress-induced self-grooming and pinpoint a critical role of LSv in this ethologically important behaviour.

17 September 2015 in Sensors
Verified
Journal Article
Open access
PDF file
RPRong-Chao Peng
Rong-Chao Peng
CYChris Yan
Chris Yan
NZNing-Ling Zhang
Ning-Ling Zhang
WLWan-Hua Lin
Wan-Hua Lin
XZXiao-Lin Zhou
Xiao-Lin Zhou
YZYuan-Ting Zhang
Yuan-Ting Zhang
Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by the microphone of a smartphone. A cold-pressor experiment was performed in 32 healthy subjects, with a smartphone to acquire heart sound signals and with a commercial device to measure continuous blood pressure. The Fourier spectrum of the second heart sound and the blood pressure were regressed using a support vector machine, and the accuracy of the regression was evaluated using 10-fold cross-validation. Statistical analysis showed that the mean correlation coefficients between the predicted values from the regression model and the measured values from the commercial device were 0.707, 0.712, and 0.748 for systolic, diastolic, and mean blood pressure, respectively, and that the mean errors were less than 5 mmHg, with standard deviations less than 8 mmHg. These results suggest that this technique is of potential use for cuffless and continuous blood pressure monitoring and it has promising application in home healthcare services.

6 February 2015 in Physiological Measurement
Verified
Journal Article
Open access
RPRong-Chao Peng
Rong-Chao Peng
CYChris Yan
Chris Yan
XZXiao-Lin Zhou
Xiao-Lin Zhou
NZNing-Ling Zhang
Ning-Ling Zhang
WLWan-Hua Lin
Wan-Hua Lin
YZYuan-Ting Zhang
Yuan-Ting Zhang
Heart rate variability is a useful clinical tool for autonomic function assessment and cardiovascular disease diagnosis. To investigate the dynamic changes of sympathetic and parasympathetic activities during the cold pressor test, we used a time-varying autoregressive model for the time-frequency analysis of heart rate variability in 101 healthy subjects. We found that there were two sympathetic peaks (or two parasympathetic valleys) when the abrupt changes of temperature (ACT) occurred at the beginning and the end of the cold stimulus and that the sympathetic and parasympathetic activities returned to normal in about the last 2 min of the cold stimulus. These findings suggested that the ACT rather than the low temperature was the major cause of the sympathetic excitation and parasympathetic withdrawal. We also found that the onsets of the sympathetic peaks were 4-26 s prior to the ACT and the returns to normal were 54-57 s after the ACT, which could be interpreted as the feedforward and adaptation of the autonomic regulation process in the human body, respectively. These results might be helpful for understanding the regulatory mechanisms of the autonomic system and its effects on the cardiovascular system.

23 September 2019 in IEEE Access
Verified
Journal Article
Open access
CYChris Yan
Chris Yan
RPRong-Chao Peng
Rong-Chao Peng
YZYuan-Ting Zhang
Yuan-Ting Zhang
DHDerek Ho
Derek Ho
Cuffless blood pressure monitoring is critical for the prevention and early diagnosis of a wide variety of cardiovascular diseases. However, cuffless blood pressure estimation devices suitable for home healthcare applications still suffer from numerous technological limitations. In this paper, we propose a novel method to continuously estimate blood pressure from the pulse morphology of the photoplethysmographic signals, acquired by a commercial oximeter. We conducted cold-pressor tests for 70 healthy subjects, simultaneously acquiring the photoplethysmograms from the oximeter and the continuous blood pressure from a commercial sphygmomanometer as a reference. The shape of each pulse was extracted, normalized, and regressed with the reference blood pressure using support vector machines. The performance of the regression model for each subject was evaluated using 10-fold cross-validation. Results showed that the predicted values from the regression model were highly correlated with the reference measurements from the commercial device. The mean correlation coefficients were 0.748, 0.754, and 0.775 for systolic, diastolic, and mean blood pressures, respectively. The mean errors were 0.043 mmHg, 0.011 mmHg, and 0.008 mmHg, with standard deviations of 5.001 mmHg, 3.689 mmHg, and 4.140 mmHg for systolic, diastolic, and mean blood pressures, respectively. These results suggest high feasibility of the proposed method to be employed in wearable medical and home healthcare devices.

1 September 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
YLYun Lu
Yun Lu
MWMingjiang Wang
Mingjiang Wang
LYLongxin Yao
Longxin Yao
HSHongcai Shen
Hongcai Shen
Wanqing WuWanqing Wu
Wanqing Wu
SCShixiong Chen
Shixiong Chen