Martin Browne

Martin Browne

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2010 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
ADAlex Dickinson
Alex Dickinson
ATA. C. Taylor
A. C. Taylor
HOH. Ozturk
H. Ozturk
MBMartin Browne
Martin Browne
Computational biomechanical models are useful tools for supporting orthopedic implant design and surgical decision making, but because they are a simplification of the clinical scenario they must be carefully validated to ensure that they are still representative. The goal of this study was to assess the validity of the generation process of a structural finite element model of the proximal femur employing the digital image correlation (DIC) strain measurement technique. A finite element analysis model of the proximal femur subjected to gait loading was generated from a CT scan of an analog composite femur, and its predicted mechanical behavior was compared with an experimental model. Whereas previous studies have employed strain gauging to obtain discreet point data for validation, in this study DIC was used for full field quantified comparison of the predicted and experimentally measured strains. The strain predicted by the computational model was in good agreement with experimental measurements, with R2 correlation values from 0.83 to 0.92 between the simulation and the tests. The sensitivity and repeatability of the strain measurements were comparable to or better than values reported in the literature for other DIC tests on tissue specimens. The experimental-model correlation was in the same range as values obtained from strain gauging, but the DIC technique produced more detailed, full field data and is potentially easier to use. As such, the findings supported the validity of the model generation process, giving greater confidence in the model’s predictions, and digital image correlation was demonstrated as a useful tool for the validation of biomechanical models.

29 June 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
JSJ. W. Steer
J. W. Steer
PWPeter Worsley
Peter Worsley
MBMartin Browne
Martin Browne
ADAlex Dickinson
Alex Dickinson
It has been proposed that finite element analysis can complement clinical decision making for the appropriate design and manufacture of prosthetic sockets for amputees. However, clinical translation has not been achieved, in part due to lengthy solver times and the complexity involved in model development. In this study, a parametric model was created, informed by variation in (i) population-driven residuum shape morphology, (ii) soft tissue compliance and (iii) prosthetic socket design. A Kriging surrogate model was fitted to the response of the analyses across the design space enabling prediction for new residual limb morphologies and socket designs. It was predicted that morphological variability and prosthetic socket design had a substantial effect on socket-limb interfacial pressure and shear conditions as well as sub-dermal soft tissue strains. These relationships were investigated with a higher resolution of anatomical, surgical and design variability than previously reported, with a reduction in computational expense of six orders of magnitude. This enabled real-time predictions (1.6 ms) with error vs the analytical solutions of < 4 kPa in pressure at residuum tip, and < 3% in soft tissue strain. As such, this framework represents a substantial step towards implementation of finite element analysis in the prosthetics clinic.

1 August 2012 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
RGRajesh Ghosh
Rajesh Ghosh
SGSanjay Gupta
Sanjay Gupta
ADAlex Dickinson
Alex Dickinson
MBMartin Browne
Martin Browne
A detailed understanding of the changes in load transfer due to implantation is necessary to identify potential failure mechanisms of orthopedic implants. Computational finite element (FE) models provide full field data on intact and implanted bone structures, but their validity must be assessed for clinical relevance. The aim of this study was to test the validity of FE predicted strain distributions for the intact and implanted pelvis using the digital image correlation (DIC) strain measurement technique. FE models of an in vitro hemipelvis test setup were produced, both intact and implanted with an acetabular cup. Strain predictions were compared to DIC and strain rosette measurements. Regression analysis indicated a strong linear relationship between the measured and predicted strains, with a high correlation coefficient (R = 0.956 intact, 0.938 implanted) and a low standard error of the estimate (SE = 69.53 με, 75.09 με). Moreover, close agreement between the strain rosette and DIC measurements improved confidence in the validity of the DIC technique. The FE model therefore was supported as a valid predictor of the measured strain distribution in the intact and implanted composite pelvis models, confirming its suitability for further computational investigations.

18 November 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
JSJ. W. Steer
J. W. Steer
PGP. A. Grudniewski
P. A. Grudniewski
MBMartin Browne
Martin Browne
PWPeter Worsley
Peter Worsley
ASA. J. Sobey
A. J. Sobey
ADAlex Dickinson
Alex Dickinson
In post-amputation rehabilitation, a common goal is to return to ambulation using a prosthetic limb, suspended by a customised socket. Prosthetic socket design aims to optimise load transfer between the residual limb and mechanical limb, by customisation to the user. This is a time-consuming process, and with the increase in people requiring these prosthetics, it is vital that these personalised devices can be produced rapidly while maintaining excellent fit, to maximise function and comfort. Prosthetic sockets are designed by capturing the residual limb’s shape and applying a series of geometrical modifications, called rectifications. Expert knowledge is required to achieve a comfortable fit in this iterative process. A variety of rectifications can be made, grouped into established strategies [e.g. in transtibial sockets: patellar tendon bearing (PTB) and total surface bearing (TSB)], creating a complex design space. To date, adoption of advanced engineering solutions to support fitting has been limited. One method is numerical optimisation, which allows the designer a number of likely candidate solutions to start the design process. Numerical optimisation is commonly used in many industries but not prevalent in the design of prosthetic sockets. This paper therefore presents candidate shape optimisation methods which might benefit the prosthetist and the limb user, by blending the state of the art from prosthetic mechanical design, surrogate modelling and evolutionary computation. The result of the analysis is a series of prosthetic socket designs that preferentially load and unload the pressure tolerant and intolerant regions of the residual limb. This spectrum is bounded by the general forms of the PTB and TSB designs, with a series of variations in between that represent a compromise between these accepted approaches. This results in a difference in pressure of up to 31 kPa over the fibula head and 14 kPa over the residuum tip. The presented methods would allow a trained prosthetist to rapidly assess these likely candidates and then to make final detailed modifications and fine-tuning. Importantly, insights gained about the design should be seen as a compliment, not a replacement, for the prosthetist’s skill and experience. We propose instead that this method might reduce the time spent on the early stages of socket design and allow prosthetists to focus on the most skilled and creative tasks of fine-tuning the design, in face-to-face consultation with their client.

1 September 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
ADAlex Dickinson
Alex Dickinson
ATAndrew Taylor
Andrew Taylor
MBMartin Browne
Martin Browne
Hip resurfacing demonstrates good survivorship as a treatment for young patients with osteoarthritis, but occasional implant loosening failures occur. On the femoral side there is radiographic evidence suggesting that the implant stem bears load, which is thought to lead to proximal stress shielding and adaptive bone remodelling. Previous attempts aimed at reproducing clinically observed bone adaptations in response to the implant have not recreated the full set of common radiographic changes, so a modified bone adaptation algorithm was developed in an attempt to replicate more closely the effects of the prosthesis on the host bone. The algorithm features combined implant–bone interface healing and continuum bone remodelling. It was observed that remodelling simulations that accounted for progressive gap filling at the implant–bone interface predicted the closest periprosthetic bone density changes to clinical X-rays and DEXA data. This model may contribute to improved understanding of clinical failure mechanisms with traditional hip resurfacing designs and enable more detailed pre-clinical analysis of new designs.

1 October 2020 in Prosthetics and Orthotics International
Verified
Journal Article
Open access
PDF file
JSJoshua W Steer
Joshua W Steer
PWPeter Worsley
Peter Worsley
MBMartin Browne
Martin Browne
ADAlex Dickinson
Alex Dickinson
Background: Finite element modelling has long been proposed to support prosthetic socket design. However, there is minimal detail in the literature to inform practice in developing and interpreting these complex, highly nonlinear models. Objectives: To identify best practice recommendations for finite element modelling of lower limb prosthetics, considering key modelling approaches and inputs. Study design: Computational modelling. Methods: This study developed a parametric finite element model using magnetic resonance imaging data from a person with transtibial amputation. Comparative analyses were performed considering socket loading methods, socket–residuum interface parameters and soft tissue material models from the literature, to quantify their effect on the residuum’s biomechanical response to a range of parameterised socket designs. Results: These variables had a marked impact on the finite element model’s predictions for limb–socket interface pressure and soft tissue shear distribution. Conclusions: All modelling decisions should be justified biomechanically and clinically. In order to represent the prosthetic loading scenario in silico, researchers should (1) consider the effects of donning and interface friction to capture the generated soft tissue shear stresses, (2) use representative stiffness hyperelastic material models for soft tissues when using strain to predict injury and (3) interrogate models comparatively, against a clinically-used control.