Peter Worsley

Dr. Peter Worsley

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Journal of Wound Care
Verified
Journal Article
Open access
AGAmit Gefen
Amit Gefen
Paulo AlvesPaulo Alves
Paulo Alves
GCGuido Ciprandi
Guido Ciprandi
FCFiona M. Coyer
Fiona M. Coyer
CMCatherine T Milne
Catherine T Milne
ASAnna-Barbara Schlüer
Anna-Barbara Schlüer

1 April 2013 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
PWPeter Worsley
Peter Worsley
MWMartin Warner
Martin Warner
SMSarah Mottram
Sarah Mottram
SGStephan Gadola
Stephan Gadola
HVH.E.J. Veeger
H.E.J. Veeger
MSMaria Stokes
Maria Stokes

9 March 2017 in Medical Engineering & Physics
Verified
Journal Article
Open access
ADAlex Dickinson
Alex Dickinson
JSJ.W. Steer
J.W. Steer
PWPeter Worsley
Peter Worsley
The care and rehabilitation of individuals after lower limb amputation presents a substantial and growing socioeconomic challenge. Clinical outcome is closely linked to successful functional rehabilitation with a prosthetic limb, which depends upon comfortable prosthetic limb - residual limb load transfer. Despite early interest in the 1980s, the amputated limb has received considerably less attention in computational biomechanical analysis than other subjects, such as arthroplasty. This systematic literature review investigates the state of the art in residual limb finite element analysis published since 2000. The identified studies were grouped into the following categories: (1) residuum-prosthesis interface mechanics; (2) residuum soft tissue internal mechanics; (3) identification of residuum tissue characteristics; (4) proposals for incorporating FEA into the prosthesis fitting process; (5) analysis of the influence of prosthetic componentry concepts to improve load transfer to the residuum, such as the monolimb and structural socket compliance; and (6) analysis of osseointegrated (OI) prostheses. The state of the art is critically appraised in order to form recommendations for future modeling studies in terms of geometry, material properties, boundary conditions, interface models, and relevant but un-investigated issues. Finally, the practical implementation of these approaches is discussed.

14 July 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Alix ChadwellAlix Chadwell
Alix Chadwell
LDLaura Diment
Laura Diment
MMM. Micó-Amigo
M. Micó-Amigo
DRDafne Zuleima Morgado Ramirez
Dafne Zuleima Morgado Ramirez
ADAlex Dickinson
Alex Dickinson
PWPeter Worsley
Peter Worsley
Background: Understanding how prostheses are used in everyday life is central to the design, provision and evaluation of prosthetic devices and associated services. This paper reviews the scientific literature on methodologies and technologies that have been used to assess the daily use of both upper- and lower-limb prostheses. It discusses the types of studies that have been undertaken, the technologies used to monitor physical activity, the benefits of monitoring daily living and the barriers to long-term monitoring, with particular focus on low-resource settings.Methods: A systematic literature search was conducted in PubMed, Web of Science, Scopus, CINAHL and EMBASE of studies that monitored the activity of prosthesis users during daily-living.Results: Sixty lower-limb studies and 9 upper-limb studies were identified for inclusion in the review. The first studies in the lower-limb field date from the 1990s and the number has increased steadily since the early 2000s. In contrast, the studies in the upper-limb field have only begun to emerge over the past few years. The early lower-limb studies focused on the development or validation of actimeters, algorithms and/or scores for activity classification. However, most of the recent lower-limb studies used activity monitoring to compare prosthetic components. The lower-limb studies mainly used step-counts as their only measure of activity, focusing on the amount of activity, not the type and quality of movements. In comparison, the small number of upper-limb studies were fairly evenly spread between development of algorithms, comparison of everyday activity to clinical scores, and comparison of different prosthesis user populations. Most upper-limb papers reported the degree of symmetry in activity levels between the arm with the prosthesis and the intact arm.Conclusions: Activity monitoring technology used in conjunction with clinical scores and user feedback, offers significant insights into how prostheses are used and whether they meet the user’s requirements. However, the cost, limited battery-life and lack of availability in many countries mean that using sensors to understand the daily use of prostheses and the types of activity being performed has not yet become a feasible standard clinical practice. This review provides recommendations for the research and clinical communities to advance this area for the benefit of prosthesis users.

12 April 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
DBDan L. Bader
Dan L. Bader
PWPeter Worsley
Peter Worsley
There are many situations where the skin and underlying soft tissues are compromised by mechanical loading in the form or pressure, or pressure in combination with shear. If sustained, this can lead to damage in the tissues particularly adjacent to bony prominences, resulting in chronic wounds. An array of bioengineering technologies have been adopted to assess the integrity of loaded soft tissues. This paper aims to review these approaches for the quantification, simulation and early detection of mechanically-induced skin damage. The review considers different measurements at the interface between the skin and support surface/medical device, involving pressure, shear, friction and the local microclimate. The potential of the techniques to monitor the physiological response of the skin to these external stimuli including biophysical measurement devices and sampling of biofluids are critically analysed. In addition, it includes an analysis of medical imaging technologies and computational modelling to provide a means by which tissue deformation can be quantified and thresholds for tissue damage defined. Bioengineering measurement and imaging technologies have provided an insight into the temporal status of loaded skin. Despite the advances in technology, to date, the translation to clinical tools which are robust and cost effective has been limited. There is a need to adapt existing technologies and simulation platforms to enable patients, carers and clinicians to employ appropriate intervention strategies to minimise soft tissue damage.

29 June 2019 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
JSJ. W. Steer
J. W. Steer
PWPeter Worsley
Peter Worsley
MBMartin Browne
Martin Browne
ADAlex Dickinson
Alex Dickinson
It has been proposed that finite element analysis can complement clinical decision making for the appropriate design and manufacture of prosthetic sockets for amputees. However, clinical translation has not been achieved, in part due to lengthy solver times and the complexity involved in model development. In this study, a parametric model was created, informed by variation in (i) population-driven residuum shape morphology, (ii) soft tissue compliance and (iii) prosthetic socket design. A Kriging surrogate model was fitted to the response of the analyses across the design space enabling prediction for new residual limb morphologies and socket designs. It was predicted that morphological variability and prosthetic socket design had a substantial effect on socket-limb interfacial pressure and shear conditions as well as sub-dermal soft tissue strains. These relationships were investigated with a higher resolution of anatomical, surgical and design variability than previously reported, with a reduction in computational expense of six orders of magnitude. This enabled real-time predictions (1.6 ms) with error vs the analytical solutions of < 4 kPa in pressure at residuum tip, and < 3% in soft tissue strain. As such, this framework represents a substantial step towards implementation of finite element analysis in the prosthetics clinic.