Endovascular embolization agents are particles and fluids that can be released into the bloodstream through a catheter to mechanically and/or biologically occlude a target vessel, either temporarily or permanently. Vascular embolization agents are available as solids, liquids, and suspensions. Although liquid adhesives (glues) have been used as embolic agents for decades, experience with them for peripheral applications is generally limited. Cyanoacrylates are the main liquid adhesives used for endovascular interventions and have a major role in managing vascular abnormalities, bleeding, and many vascular diseases. They can only be injected as a mixture with ethiodized oil, which provides radiopacity and modulates the polymerization rate. This review describes the characteristics, properties, mechanisms of action, modalities of use, and indications of the cyanoacrylate-Lipiodol® combination for peripheral embolization.
To compare image quality and the radiation dose of computed tomography pulmonary angiography (CTPA) subjected to the first deep learning-based image reconstruction (DLR) (50%) algorithm, with images subjected to the hybrid-iterative reconstruction (IR) technique (50%). One hundred forty patients who underwent CTPA for suspected pulmonary embolism (PE) between 2018 and 2019 were retrospectively reviewed. Image quality was assessed quantitatively (image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) and qualitatively (on a 5-point scale). Radiation dose parameters (CT dose index, CTDIvol; and dose-length product, DLP) were also recorded. Ninety-three patients were finally analyzed, 48 with hybrid-IR and 45 with DLR images. The image noise was significantly lower and the SNR (24.4 ± 5.9 vs. 20.7 ± 6.1) and CNR (21.8 ± 5.8 vs. 18.6 ± 6.0) were significantly higher on DLR than hybrid-IR images (p < 0.01). DLR images received a significantly higher score than hybrid-IR images for image quality, with both soft (4.4 ± 0.7 vs. 3.8 ± 0.8) and lung (4.1 ± 0.7 vs. 3.6 ± 0.9) filters (p < 0.01). No difference in diagnostic confidence level for PE between both techniques was found. CTDIvol (4.8 ± 1.4 vs. 4.0 ± 1.2 mGy) and DLP (157.9 ± 44.9 vs. 130.8 ± 41.2 mGy∙cm) were lower on DLR than hybrid-IR images. DLR both significantly improved the image quality and reduced the radiation dose of CTPA examinations as compared to the hybrid-IR technique.
Objective: To compare the image quality of computed tomography angiography of the supra-aortic arteries (CTSA) at different tube voltages in low doses settings with deep learning-based image reconstruction (DLR) vs. hybrid iterative reconstruction (H-IR). Methods: We retrospectively reviewed 102 patients who underwent CTSA systematically reconstructed with both DLR and H-IR. We assessed the image quality both quantitatively and qualitatively at 11 arterial segmental levels and 3 regional levels. Radiation-dose parameters were recorded and the effective dose was calculated. Eighty-six patients were eligible for analysis Of these patients, 27 were imaged with 120 kVp, 30 with 100 kVp, and 29 with 80 kVp. Results: The effective dose in 120 kVp, 100 kVp and 80 kVp was 1.5 ± 0.4 mSv, 1.1 ± 0.3 mSv and 0.68 ± 0.1 mSv, respectively (p < 0.01). Comparing 80 kVp + DLR vs. 120 and 100 kVp + H-IR CT scans, the mean overall arterial attenuation was about 64% and 34% higher (625.9 ± 118.5 HU vs. 382.3 ± 98.6 HU and 468 ± 118.5 HU; p < 0.01) without a significant difference in terms of image noise (17.7 ± 4.9 HU vs. 17.5 ± 5.2; p = 0.7 and 18.1 ± 5.4; p = 0.3) and signal-to-ratio increased by 59% and 33%, respectively (37.9 ± 12.3 vs. 23.8 ± 9.7 and 28.4 ± 12.5). This protocol also provided superior image quality in terms of qualitative parameters, compared to standard-kVp protocols with H-IR. Highest subjective image-quality grades for vascular segments close to the aorta were obtained with the 100 kVp + DLR protocol. Conclusions: DLR significantly reduced image noise and improved the overall image quality of CTSA with both low and standard tube voltages and at all vascular segments. CT that was acquired with 80 kVp and reconstructed with DLR yielded better overall image quality compared to higher kVp values with H-IR, while reducing the radiation dose by half, but it has limitations for arteries that are close to the aortic arch.
Although introduced decades ago, few cyanoacrylate glues have been approved for endovascular use, despite evidence of their usefulness, notably for complex procedures suchas hemostatic embolization. Indications include massive bleeding requiring emergent hemostasis and prevention of severe bleeding during scheduled surgery to remove a hypervascular tumor. Adding radiopaque Lipiodol Ultra Fluid® (LUF) modulates glue polymerization and allows fluoroscopic guidance, but few comparative in vivo studies have assessed the impact of the resulting change in glue concentration or of other factors such as target-vessel blood flow. In a rabbit model, we used ex vivo X-ray microtomography to assess the results of in vivo renal-artery embolization by various mixtures of N-butyl cyanoacrylate (NBCA), metacryloxysulfolane, and LUF. Overall, penetration to the superficial interlobular arteries was achieved in about two-thirds of cases and into the capillaries in nearly half the cases, while cast fragmentation was seen in slightly more than half the cases. Greater NBCA dilution and the blocked-blood-flow technique were independently associated with greater distality of penetration. Blocked-blood-flow injection was independently associated with absence of fragmentation, capillary penetration, a shorter cast-to-capsule distance, and higher cast attenuation. A larger mixture volume was independently associated with higher indexed cast ratio and deeper penetration. Finally, microtomography is an adapted tool to assess ex vivo distribution of glue cast.
Objective. Lumbar radiculopathy mainly originates in the spine (lumbar disc herniation or spine osteoarthritis) but can sometimes be explained by extra-spinal nerve compression or confused with referred pain mimicking radiculopathy. Our main objective was to demonstrate the clinical benefit of the large-field coronal STIR (coroSTIR) sequence in the etiological assessment of lumbar radiculopathy with a duration of more than six weeks. Materials and methods. Six hundred consecutive lumbar MRI scans performed using the same protocol were retrospectively reviewed. Two musculoskeletal radiologists independently assessed the coroSTIR sequence for the presence of extra-spinal anomalies (ESA) that could explain or contribute to the lumbar radiculopathy. The presence of an ESA was then correlated with sex, age, topography and lateralization of radiculopathy, history of vertebral surgery, as well as the presence of a spinal cause explaining the symptoms. Extra-spinal incidentalomas (ESI) with potential clinical impact visible only on the coroSTIR sequence were also systematically reported. Results. An extra-spinal cause was detected on the coroSTIR sequence in 68 cases (11.3%), mainly gluteal tendinobursitis (30.9%), congestive hip osteoarthritis (25%), degenerative sacroiliac arthropathy (14.7%), or inflammatory sacroilitis (7.3%). Their prevalence was significantly correlated in multivariate regression with age (58 years vs. 53 years, p = 0.01), but not with the type of radiating pain (sciatica or cruralgia). The presence of ESI was also frequent (70 cases, 11.7%), including some potentially severe diagnoses (38% of tumor or pseudo-tumor mass requiring further assessment or monitoring). Conclusions. Considering its acceptable acquisition time, the detection of a significant number of potentially symptom-related extra-spinal anomalies, and the discovery of a non-negligible number of extra-spinal incidentalomas with potential clinical impact, the coronal STIR should be performed systematically in routine MRI for lumbar radiculopathy.
To assess the efficacy and safety of the Leo stent used alone or with coiling to treat complex intracranial aneurysms (IAs) not eligible for simple or balloon-assisted coiling, this single-center retrospective study included consecutive adults with ruptured or unruptured IAs treated in 2011–2018 by stenting with or without coiling. The indication for stenting was IA complexity precluding simple or balloon-assisted coiling. Extensive data on the patients, IAs, antiplatelet treatments, procedures, and outcomes over the first 36 months were collected. Risk factors for early complications (univariate analysis) and delayed ischemia (multivariate analysis) were sought. We include 64 patients with 66 IAs. The procedural success rate was 65/66 (98.5%). Obliteration was Raymond Roy class I or II for 85% of IAs. Six patients died including four of the 12 patients presenting with subarachnoid hemorrhage, which was the only significant risk factor for early major complications. At 1 month, 45/64 (69%) had no disabilities. No rebleeding was reported. Ischemia was detected by routine MRI in 20 (35%) of the 57 patients with long-term data and was asymptomatic in 14. The stent-within-a-stent configuration was the only independent risk factor for ischemia. The Leo stent used alone or with coils to manage challenging IAs was associated with a high procedural success rate and complete or nearly complete IA obliteration of 85% of IAs. The high frequency of ischemia is ascribable to our use of routine serial MRI. In patients with bleeding, the Leo stent was associated with an excess risk of early, major, intracranial complications, as compared to patients without bleeding. Long-term follow-up was marked by the occurrence of ischemic events in the vascular territory of the stent, mostly silent.