To compare image quality and the radiation dose of computed tomography pulmonary angiography (CTPA) subjected to the first deep learning-based image reconstruction (DLR) (50%) algorithm, with images subjected to the hybrid-iterative reconstruction (IR) technique (50%). One hundred forty patients who underwent CTPA for suspected pulmonary embolism (PE) between 2018 and 2019 were retrospectively reviewed. Image quality was assessed quantitatively (image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)) and qualitatively (on a 5-point scale). Radiation dose parameters (CT dose index, CTDIvol; and dose-length product, DLP) were also recorded. Ninety-three patients were finally analyzed, 48 with hybrid-IR and 45 with DLR images. The image noise was significantly lower and the SNR (24.4 ± 5.9 vs. 20.7 ± 6.1) and CNR (21.8 ± 5.8 vs. 18.6 ± 6.0) were significantly higher on DLR than hybrid-IR images (p < 0.01). DLR images received a significantly higher score than hybrid-IR images for image quality, with both soft (4.4 ± 0.7 vs. 3.8 ± 0.8) and lung (4.1 ± 0.7 vs. 3.6 ± 0.9) filters (p < 0.01). No difference in diagnostic confidence level for PE between both techniques was found. CTDIvol (4.8 ± 1.4 vs. 4.0 ± 1.2 mGy) and DLP (157.9 ± 44.9 vs. 130.8 ± 41.2 mGy∙cm) were lower on DLR than hybrid-IR images. DLR both significantly improved the image quality and reduced the radiation dose of CTPA examinations as compared to the hybrid-IR technique.
16 February 2024 in Diagnostic and Interventional Imaging
The purpose of this study was to evaluate the ability of ultra-high-resolution computed tomography (UHR-CT) to assess stapes and chorda tympani nerve anatomy using a deep learning (DLR), a model-based, and a hybrid iterative reconstruction algorithm compared to simulated conventional CT. CT acquisitions were performed with a Mercury 4.0 phantom. Images were acquired with a 1024 × 1024 matrix and a 0.25 mm slice thickness and reconstructed using DLR, model-based, and hybrid iterative reconstruction algorithms. To simulate conventional CT, images were also reconstructed with a 512 × 512 matrix and a 0.5 mm slice thickness. Spatial resolution, noise power spectrum, and objective high-contrast detectability were compared. Three radiologists evaluated the clinical acceptability of these algorithms by assessing the thickness and image quality of the stapes footplate and superstructure elements, as well as the image quality of the chorda tympani nerve bony and tympanic segments using a 5-point confidence scale on 13 temporal bone CT examinations reconstructed with the four algorithms. UHR-CT provided higher spatial resolution than simulated conventional CT at the penalty of higher noise. DLR and model-based iterative reconstruction provided better noise reduction than hybrid iterative reconstruction, and DLR had the highest detectability index, regardless of the dose level. All stapedial structure thicknesses were thinner using UHR-CT by comparison with conventional simulated CT (P < 0.009). DLR showed the best visualization scores compared to the other reconstruction algorithms (P < 0.032). UHR-CT with DLR results in less noise than UHR-CT with hybrid iterative reconstruction and significantly improves stapes and tympanic chorda tympani nerve depiction compared to simulated conventional CT and UHR-CT with iterative reconstruction.
13 May 2024 in Diagnostic and Interventional Imaging
The purpose of this study was to evaluate the achievable radiation dose reduction of an ultra-high resolution computed tomography (UHR-CT) scanner using deep learning reconstruction (DLR) while maintaining temporal bone image quality equal to or better than high-resolution CT (HR-CT). UHR-CT acquisitions were performed with variable tube voltages and currents at eight different dose levels (volumic CT dose index [CTDIvol] range: 4.6-79 mGy), 10242 matrix, and 0.25 mm slice thickness and reconstructed using DLR and hybrid iterative reconstruction (HIR) algorithms. HR-CT images were acquired using a standard protocol (120 kV/220 mAs; CTDI vol, 54.2 mGy, 5122 matrix, and 0.5 mm slice thickness). Two radiologists rated the image quality of seven structures using a five point confidence scale on six cadaveric temporal bone CTs. A global image quality score was obtained for each CT protocol by summing the image quality scores of all structures. With DLR, UHR-CT at 120 kV/220 mAs (CTDIvol, 50.9 mGy) and 140 kV/220 mAs (CTDIvol, 79 mGy) received the highest global image quality scores (4.88 ± 0.32 [standard deviation (SD)] [range: 4-5] and 4.85 ± 0.35 [range: 4-5], respectively; P = 0.31), while HR-CT at 120 kV/220 mAs and UHR-CT at 120 kV/20 mAs received the lowest (i.e., 3.14 ± 0.75 [SD] [range: 2-5] and 2.97 ± 0.86 [SD] [range: 1-5], respectively; P = 0.14). All the DLR protocols had better image quality scores than HR-CT with HIR. UHR-CT with DLR can be performed with up to a tenfold reduction in radiation dose compared to HR-CT with HIR while maintaining or improving image quality.
Objective: To compare the image quality of computed tomography angiography of the supra-aortic arteries (CTSA) at different tube voltages in low doses settings with deep learning-based image reconstruction (DLR) vs. hybrid iterative reconstruction (H-IR). Methods: We retrospectively reviewed 102 patients who underwent CTSA systematically reconstructed with both DLR and H-IR. We assessed the image quality both quantitatively and qualitatively at 11 arterial segmental levels and 3 regional levels. Radiation-dose parameters were recorded and the effective dose was calculated. Eighty-six patients were eligible for analysis Of these patients, 27 were imaged with 120 kVp, 30 with 100 kVp, and 29 with 80 kVp. Results: The effective dose in 120 kVp, 100 kVp and 80 kVp was 1.5 ± 0.4 mSv, 1.1 ± 0.3 mSv and 0.68 ± 0.1 mSv, respectively (p < 0.01). Comparing 80 kVp + DLR vs. 120 and 100 kVp + H-IR CT scans, the mean overall arterial attenuation was about 64% and 34% higher (625.9 ± 118.5 HU vs. 382.3 ± 98.6 HU and 468 ± 118.5 HU; p < 0.01) without a significant difference in terms of image noise (17.7 ± 4.9 HU vs. 17.5 ± 5.2; p = 0.7 and 18.1 ± 5.4; p = 0.3) and signal-to-ratio increased by 59% and 33%, respectively (37.9 ± 12.3 vs. 23.8 ± 9.7 and 28.4 ± 12.5). This protocol also provided superior image quality in terms of qualitative parameters, compared to standard-kVp protocols with H-IR. Highest subjective image-quality grades for vascular segments close to the aorta were obtained with the 100 kVp + DLR protocol. Conclusions: DLR significantly reduced image noise and improved the overall image quality of CTSA with both low and standard tube voltages and at all vascular segments. CT that was acquired with 80 kVp and reconstructed with DLR yielded better overall image quality compared to higher kVp values with H-IR, while reducing the radiation dose by half, but it has limitations for arteries that are close to the aortic arch.
Background and purpose Intracranial aneurysms are a frequently occurring disease, with an estimated prevalence of 2–5% in the general population. They usually remain silent until rupture occurs, with a mortality rate of 35–50% and a high rate of morbidity, including long-term disability. However, preventative treatments have their own risk of complications and morbi-mortality rates, including stroke and hemorrhage. ECG-gated four-dimensional CT angiography (4D-CTA) allows the acquisition of time-resolved three-dimensional reconstructions. The aim of our study was to evaluate different intracranial aneurysm metrics over the cardiac cycle using ECG-gated 4D-CTA. Materials and methods ECG-gated 4D-CTA datasets were acquired in patients presenting with intracranial aneurysms. Seven aneurysm metrics, including aneurysm height, aneurysm length, ostium width, aspect ratio, ostium area, volume, and volume-to-ostium ratio, were analysed over different cardiac phases. Intra-reader agreement, inter-reader agreement, and inter-cycle agreement were calculated through the intraclass correlation coefficient. Results Twenty-one aneurysms from 11 patients were considered for inclusion. Post-processing failed for three aneurysms, and 18 aneurysms were finally analysed. There was good intra-reader agreement for each metric (ICC >0.9). Agreements among three consecutive cardiac cycles were calculated for six aneurysms and were especially good for the volume metric (ICC >0.9). Volume variation appears to be the most relevant metric and seems especially perceptible for aneurysms larger than 5 mm. Conclusions Quantification of aneurysm volume changes during the cardiac cycle seems quantitatively possible and reproducible, especially for aneurysms larger than 5 mm. Further studies need to be conducted to validate this parameter for intracranial aneurysm assessment.