Ahmad Zaidi Bin Abdullah

Dr. Ahmad Zaidi Bin Abdullah

Universiti Malaysia Perlis, Kangar, Perlis, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2015
Verified
Book Chapter
Closed access
PDF file
YLYeng Seng Lee
Yeng Seng Lee
FMFareq Malek
Fareq Malek
CMCheng Ee Meng
Cheng Ee Meng
WLWei Wen Liu
Wei Wen Liu
FWFwen Hoon Wee
Fwen Hoon Wee
MJMohd Asri Jusoh
Mohd Asri Jusoh

1 December 2018
Verified
Conference Paper
Closed access
AAAhmad Zaidi Bin Abdullah
Ahmad Zaidi Bin Abdullah
MOHAMAD NUR KHAIRUL HAFIZI ROHANIMOHAMAD NUR KHAIRUL HAFIZI ROHANI
MOHAMAD NUR KHAIRUL HAFIZI ROHANI
MIM. Isa
M. Isa
HHH. Hamid
H. Hamid
SAS.N.M. Arshad
S.N.M. Arshad
MOM. Othman
M. Othman
This paper presents the measurement and detection techniques of partial discharge (PD) on medium voltage power cable with the idea to propose simplest and accurate online on-site PD measurement. The Rogowski Coil (RC) has been choose as measuring sensor to detect and measure PD signal at site. A real 11kV site at northern Malaysia substation was selected to perform the measurement with considering current PD measurement technique by utility. The propose method is used to locate the PD signal in three phase MV underground cross-link polyethylene (XLPE) cable with 240 mm 2 size and 3 km length between two substations. On-site measurement has been carried out to verify the ability of method to detect PD signal and compare with previous method by utility. The analysis of PD signal using FFT was performed to characterize the actual PD signal. In this paper, results indicate that the measurement technique performed better and easier in detecting PD signal for online condition.

1 June 2013
Verified
Conference Paper
Closed access
MIMuhd Hafizi Idris
Muhd Hafizi Idris
MAMohd Saufi Ahmad
Mohd Saufi Ahmad
AAAhmad Zaidi Bin Abdullah
Ahmad Zaidi Bin Abdullah
SHSurya Hardi
Surya Hardi
This paper describes an adaptive distance relaying scheme which can eliminate the effect of fault resistance on distance relay zone reach. Distance relay is commonly used as main protection to protect transmission line from any type of fault. For a stand-alone distance relay, fault resistance can make Mho type distance relay to be under reached and thus the fault will be isolated at a longer time. In this scheme, the relay detects the fault location using a two-terminal algorithm. By knowing fault location, fault voltage at the fault point can be calculated by using equivalent sequence network connection as seen from local terminal. Then, fault resistance is calculated by using simple equation considering contribution from remote terminal current. Finally, the compensation of fault resistance is done onto calculated apparent resistance as seen at relaying point. The modeling and simulation was carried out using Matlab/Simulink software. Several cases were carried out and the results show the validity of the scheme.

8 March 2023 in Journal of Advanced Research in Applied Sciences and Engineering Technology
Verified
Journal Article
Open access
PDF file
CACik Siti Khadijah Abdulah
Cik Siti Khadijah Abdulah
MOHAMAD NUR KHAIRUL HAFIZI ROHANIMOHAMAD NUR KHAIRUL HAFIZI ROHANI
MOHAMAD NUR KHAIRUL HAFIZI ROHANI
BIBAHARUDDIN ISMAIL
BAHARUDDIN ISMAIL
MIMohd Annuar Mohd Isa
Mohd Annuar Mohd Isa
ARAfifah Shuhada Rosmi
Afifah Shuhada Rosmi
MJMohamad Kamarol Mohd Jamil
Mohamad Kamarol Mohd Jamil
This paper reviews several studies of image de-noising on digital image processing and applications. Noisy images contain different noise that exist either due to environment or electronic interferences. Ergo, de-noising is crucial to eliminate the noise that disturb data collecting process. The impact of de-noising on image processing can result for accurate and precise data collected from the image. Additionally, de-noising process required several crucial steps that help to enhance knowledge on digital image and its application. Hence, study and understanding de-noising can improve multiple aspect such as image quality, data sensitivity and specificity, accuracy of the collected data, and increase the percentage of each parameter.

14 May 2015
Verified
Book Chapter
Closed access
PDF file
LZLiyana Zahid
Liyana Zahid
MMMohd Fareq Abd Malek
Mohd Fareq Abd Malek
CMCheng Ee Meng
Cheng Ee Meng
WLWei Wen Liu
Wei Wen Liu
YLYeng Seng Lee
Yeng Seng Lee
MJMohd Asri Jusoh
Mohd Asri Jusoh

1 October 2019 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
AAAhmad Zaidi Bin Abdullah
Ahmad Zaidi Bin Abdullah
MIM. Isa
M. Isa
SAS. N. M. Arshad
S. N. M. Arshad
MOHAMAD NUR KHAIRUL HAFIZI ROHANIMOHAMAD NUR KHAIRUL HAFIZI ROHANI
MOHAMAD NUR KHAIRUL HAFIZI ROHANI
HHH. S. A. Halim
H. S. A. Halim
HHH. A. Hamid
H. A. Hamid
This paper presents, wavelet based de-noising technique for on-site partial discharge (PD) measurement signal. The signal is measured from medium voltage power cable at 11 kV distribution substation. The best mother wavelet, decomposition level and the type of threshold for the de-noising technique are selected based on the signal to noise ratio (SNR) aggregation. The SNR aggregation is determined based on the minimum, maximum, mean and standard deviation parameters. The same standard de-noising procedure is applied for two different PD signals and the selection parameters are done based on the accuracy of de-noising analysis. The analysis is performed in MATLAB software environment and Daubechies 2 (db2) is found as the best mother wavelet at tenth decomposition levels with soft threshold type. This study is specifically performed to develop the de-noising procedure for on-site PD measurement. Overall results indicate that the right selection of the de-noising procedure will help to improve the PD signal detection from on–site measurement.