Jiyan Zou

Jiyan Zou


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2013 in Wireless Networks
Verified
Journal Article
Closed access
PDF file
Rencheng JinRencheng Jin
Rencheng Jin
TGTeng Gao
Teng Gao
JSJin-Yan Song
Jin-Yan Song
JZJiyan Zou
Jiyan Zou
LWLi-Ding Wang
Li-Ding Wang

13 May 2015 in Wireless Networks
Verified
Journal Article
Closed access
PDF file
TGTeng Gao
Teng Gao
JSJin-Yan Song
Jin-Yan Song
JZJiyan Zou
Jiyan Zou
JDJin-Hua Ding
Jin-Hua Ding
DWDe-Quan Wang
De-Quan Wang
Rencheng JinRencheng Jin
Rencheng Jin

13 September 2013 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
EDEnyuan Dong
Enyuan Dong
TQTaotao Qin
Taotao Qin
YWYongxing Wang
Yongxing Wang
XDXiong ying Duan
Xiong ying Duan
JZJiyan Zou
Jiyan Zou
For phase-controlled vacuum breakers, the acting time of the actuator should be precise. The variation of capacitor voltage, capacitance, and environmental temperature impact the dispersion of closing time seriously. A new technology has been put forward in this paper. It is the speed control of the vacuum breaker. This technology can be used for phase-controlled operation of vacuum breakers. By using this technology, the deviation of displacement can be corrected in real time. So the permanent-magnetic actuator (PMA) can move along with the given displacement curve. Also, the closing time is stable when the external factors, such as capacitor voltage, capacitance, and environment temperature change. The closed-loop system has been established in this paper. The proportion-differentiation (PD) algorithm and fuzzy algorithm are used in the system. The PD algorithm adjusts the coil current to ensure that different actuators have the same excitation time. And the fuzzy algorithm is used to adjust actuator displacement. With the use of the algorithm, the closing time of the breaker is stable, and mechanical properties are optimal. Based on the aforementioned theory, many experiments have been performed when external factors change, such as environment temperature, capacitance, and so on. The results prove that the displacement deviation can be corrected using this method and the closing time can be stabilized within ±0.5 ms. Therefore, not only can the accuracy of phase-controlled operation can be ensured, but the lifespan of the circuit breaker can also be prolonged.

15 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
DWDequan Wang
Dequan Wang
MLMinfu Liao
Minfu Liao
RWRufan Wang
Rufan Wang
TLTenghui Li
Tenghui Li
JQJun Qiu
Jun Qiu
JZJiyan Zou
Jiyan Zou
Vacuum arc commutation is an important process in natural-commutate hybrid direct current (DC) circuit breaker (NHCB) interruption, as the duration of vacuum arc commutation will directly affect the arcing time and interrupting time of NHCB. In this paper, the vacuum arc commutation model of NHCB was established by simplifying solid-state switch (SS) and vacuum arc voltage. Through theoretical analysis and experiments, the vacuum arc commutation characteristics of NHCB were studied. The mathematical formula of the effect of main parameters on the duration of vacuum arc commutation is obtained, and the changing law of the influence of the main parameters on the duration of the vacuum arc commutation is explored. The concept of vacuum arc commutation coefficient is proposed, and it is a key parameter that influences the vacuum arc commutation characteristics. The research on the characteristics of vacuum arc commutation can provide theoretical foundation for the structure and parameter optimization of NHCB and other equipment that uses vacuum arc commutation.

9 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
GWGongrun Wang
Gongrun Wang
YWYongxing Wang
Yongxing Wang
LZLifan Zhang
Lifan Zhang
SXShutian Xue
Shutian Xue
EDEnyuan Dong
Enyuan Dong
JZJiyan Zou
Jiyan Zou
To ensure the reliability of power supply, a dual power supply structure appears in the power distribution system. Power supply switching is a complex physical process. This paper presents a novel model of electromechanical contactors. This model can simulate the multi-physics process of power switching. This article completes the simulation framework for power switching through contactors for the first time. Among them, the structural topology for contactors is also proposed. On the basis of the novel structure topology, an equivalent magnetic circuit model is established to calculate the relationship between driving force, flux linkage, current, and displacement. Then, a co-simulation model is established between the above equations and Adams to obtain the speed characteristics and flight time of the contactor. Subsequently, through the use of Fluent and its secondary development, a magnetohydrodynamic model is established, and the above-mentioned velocity characteristics are imported into it to analyze the arcing characteristics of the contacts under the conditions of the transverse magnetic field and the insulating grid. The effectiveness of power switching is judged by comparing the flight time of the electromechanical model and the arcing time of the magnetohydrodynamic model. The prototype is manufactured and tested on the basis of simulation. Through experimental waveforms and high-speed photography, the accuracy of the simulation model and the practicability of the contactor are verified.

1 March 2002 in Journal of Shanghai University (English Edition)
Verified
Journal Article
Closed access
PDF file
JZJiyan Zou
Jiyan Zou
EDEn-Yuani Dong
En-Yuani Dong
JCJin-Xiang Chen
Jin-Xiang Chen