As a typical high specific strength and corrosion-resistant alloy, titanium alloy Ti6Al4V is widely used in the aviation, ocean, biomedical, sport, and other fields. The heat treatment method is often used to improve the material mechanical properties. To investigate the dynamic mechanical properties of titanium alloy Ti6Al4V after heat treatment, dynamic compressive experiments under high temperature and high strain rate were carried out using split Hopkinson press bar (SHPB) equipment. The stress–strain curves of Ti6Al4V alloy under different temperatures and strain rates were obtained through SHPB compressive tests. The Johnson–Cook (J–C) constitutive equation was used for expressing the stress–strain relationship of titanium alloy under large deformation. In addition, the material constants of the J–C model were fitted based on the experimental data. An orthogonal cutting simulation was performed to investigate the cutting of Ti6Al4V alloy under two different numerical calculation methods based on the established J–C model using the finite element method (FEM). The simulation results confirm that the adiabatic mode is more suitable to analyze the cutting of Ti6Al4V alloy.
25 October 2019 in IET Generation, Transmission & Distribution
The objective of this work is to present a more precisely controlled switching strategy to reduce overvoltages due to ultra‐high voltage (UHV) transmission line closing. Essentially the switching strategy is to find a suitable circuit breaker (CB) optimal instant of closing. The electric field variation in the arc‐extinguish chamber has great effect on rate of decrease of dielectric strength (RDDS), when calculating optimal instant of closing with pre‐breakdown between the contacts. The relative value k of a CB is defined as the ratio of RDDS to the rate of voltage approaching the zero cross. In this calculation, the electric field E should be as a variation due to the uneven medium of SF 6 . Consequently equations were derived from calculating the pre‐breakdown instants. The ATP model of controlled closing UHV transmission line was built for switching overvoltage simulations considering RDDS and mechanical dispersion. The simulation results show that switching overvoltages are more accurate and closer to reality when regarding the electric field E as a variation. Contrarily, assuming E as a constant will increase the risk of failure via controlled switching. Furthermore, the simulation results demonstrate that k value can change the effect of the mechanical dispersion on switching overvoltages.
13 September 2013 in IEEE Transactions on Power Delivery
For phase-controlled vacuum breakers, the acting time of the actuator should be precise. The variation of capacitor voltage, capacitance, and environmental temperature impact the dispersion of closing time seriously. A new technology has been put forward in this paper. It is the speed control of the vacuum breaker. This technology can be used for phase-controlled operation of vacuum breakers. By using this technology, the deviation of displacement can be corrected in real time. So the permanent-magnetic actuator (PMA) can move along with the given displacement curve. Also, the closing time is stable when the external factors, such as capacitor voltage, capacitance, and environment temperature change. The closed-loop system has been established in this paper. The proportion-differentiation (PD) algorithm and fuzzy algorithm are used in the system. The PD algorithm adjusts the coil current to ensure that different actuators have the same excitation time. And the fuzzy algorithm is used to adjust actuator displacement. With the use of the algorithm, the closing time of the breaker is stable, and mechanical properties are optimal. Based on the aforementioned theory, many experiments have been performed when external factors change, such as environment temperature, capacitance, and so on. The results prove that the displacement deviation can be corrected using this method and the closing time can be stabilized within ±0.5 ms. Therefore, not only can the accuracy of phase-controlled operation can be ensured, but the lifespan of the circuit breaker can also be prolonged.
In order to reveal the migration and evolution of gas molecules in the actual oil–paper insulation composite system of transformer from the molecular level, the diffusion behavior of seven gas molecules (H2, CO, CO2, CH4, C2H2, C2H4, C2H6) generated during the operation and aging of oil-immersed transformers in the oil–paper composite insulation system is studied by molecular dynamics. Firstly, based on the molecular dynamics software, the model of the oil–paper composite insulation system and the gas molecule model is constructed. In order to compare and analyze the diffusion properties of gas molecules in a single medium, a single model of insulating oil and cellulose is also constructed. Then, the diffusion coefficients of gas molecules in the insulating oil, cellulose, and oil–paper insulating composite system are simulated and calculated. And the differences in the diffusion properties of gas molecules in the three insulating mediums are discussed. Finally, the microscopic mechanism of diffusion of different gas molecules in the three mediums is analyzed. The simulation results show that among the three mediums, the diffusion coefficient of H2 is the largest, while the diffusion coefficients of the other gas molecules are not very different. The diffusion coefficients of the seven gas molecules are the smallest in the oil-immersed paper composite insulation system, followed by cellulose, while the diffusion coefficients are the largest in mineral oil. It indicates that the diffusion of gas molecules is inhibited in oil–paper insulation systems where the insulating paper is completely immersed in oil. This is mainly due to the fact that the insulating oil completely penetrates into the paper, filling the pores and voids between the fibers, resulting in a reduction in the transition vacancies of the intermediate gas molecules, which hinders the diffusion of the gas molecules.
3 August 2017 in IEEE Transactions on Plasma Science
This paper focuses on the vacuum arc commutation between the vacuum arc and the parallel-connected insulated gate bipolar transistor (IGBTs) of dc microgrid hybrid circuit breakers (HCBs). The principle of the dc HCB is analyzed and the vacuum arc commutation is the important process in dc HCB interruption, in which the arcing time and the interrupting time are depended. The test circuit of the vacuum arc commutation is established by simplifying the parallel-connected IGBTs to an on-state resistance with large thermal capacity. The influence of the magnitude of the main current, the resistance of the IGBTs, and the externally applied transverse magnetic field (TMF) on the vacuum arc commutation is investigated by the electrical measure and the development of vacuum arc which is observed by a high-speed CMOS camera. The criteria of the vacuum arc commutation are obtained. The interaction between the vacuum arc commutation and the externally applied TMF is researched and the optimal magnitude of the TMF is gained. The vacuum arc commutation characteristics of dc HCB can be useful for parameters design and control strategy.