This paper investigates the use of non-metallic portion (NMP) reclaimed from e-waste (i.e., waste printed circuit board—PCB) as replacement of natural sand in the blended cement concrete by using Metakaolin (MK) as supplementary cementitious material for its effect on the mechanical, durability, microstructural, and mineralogical properties of concrete. It was found that the blended mixes containing NMP and MK outperformed the control mix. With the addition of 10% NMP and 10% MK, the maximum compressive strength was obtained, with the splitting tensile and flexural strength following the same trend. The performance of the mixes was lowered above 10% replacement levels, although it was still better than the control mixture. When compared to other mixes, 10% NMP and 10% MK concrete had the lowest sorptivity and water absorption values, as well as the highest resistance to chloride-ion penetration. FESEM was used to confirm the results, and then XRD was used to determine the elemental classification. This study lays the groundwork for a long-term strategy for utilising NMP and MK as extremely effective concrete additives.
Lightning strikes are prevalent and inevitable natural phenomena that might cause damages during interaction with building structures and, in some cases, culminate in fires. During the last decades, several lightning strikes have caused considerable damages to cultural and heritage buildings. Furthermore, recent studies indicated a plausible connection between climate changes due to global warming and variations in the frequency and intensity of lightning. The evaluation of the structural efficiency and resilience of cultural buildings to global changes and natural risks appears significant in the light of the current scientific debate. This research aims at the assessment of lightning strikes’ effects on ancient heritage binding materials through the characterization of their thermal and electrical conductivity properties. This study focused on the performance evaluation of green and low-cost mortars based on the use of organic additives. Lime samples were reverse engineered by using a mixture of organics (fig, jaggery, black grape, banana, kadukai), which comprises the most common additives used in traditional Indian mortars. The reliability of the organic mixture in enhancing the resilience of masonry to lightning strikes was analyzed by using electromagnetic field simulation.
With the advent of global warming, research studies have indicated concerns due to its impact on thunderstorm and lightning which could have detrimental impact on structures. Though there has been substantial progress related to protection of structures against lightning, research carried out during the past decades have led the lightning community to develop improved procedures for evaluating lightning exposure to structures. The location of vulnerable points struck by lightning and hence the placement of air terminals is obtained based on Rolling Sphere Method (RSM) whereby the striking distance is obtained as a function of stroke current. However, the model ignores dynamics of propagation of downward and upward leaders, geometry of the structure etc. This aspect becomes vital for smaller rolling sphere radii for tall structures with respect to several striking points. This research proposes carrying out detailed analysis based on utilizing the Modified Rolling Sphere Method (MRSM) which is based on the concept of an upward directed leader and its interaction with the downward leader during lightning strike on a tall structure. This research involves detailed analysis of lightning protection effectiveness based on MRSM for one of the tallest World Heritage Chola temple architectures in south India. Analysis based on varying lightning stroke currents has been carried out to ascertain the vulnerable points due to varying lightning protection levels. Further, a detailed failure analysis is also carried in line with the requirements of international standards to ascertain additional lightning protection requirements that would enable effective LPS for the proposed heritage monument.