Manjula Fernando

Prof. Manjula Fernando

University of Peradeniya
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2020 in IEEE Electrical Insulation Magazine
Verified
Journal Article
Closed access
SKSarath Kumara
Sarath Kumara
Manjula FernandoManjula Fernando
Manjula Fernando
Ceramic insulators, specifically porcelain and glass insulators, have widely been used all over the world since the 19th century [1,2]. However, when such insulators are energized and exposed to different pollution environments under different climatic and weather conditions, leakage current (LC) develops along their surfaces [3-7] and eventually cause flashovers. Various remedial measures have been adopted by power utilities to mitigate this problem. Among the common methods are: (a) increasing insulator creepage (leakage) distance, (b) reducing supply voltage, (c) insulator washing (cleaning), (d) oiling or greasing (silicone) the insulator surface, and (e) insulator replacement. Composite insulators, also referred to as non-ceramic or polymeric insulators, have also been used during the last six decades as an alternative to the ceramic insulators [8-10]. The housing materials most often used have been silicone rubber (SIR) [11] and ethylene-propylene-diene-monomer based rubber (EPDM) [12]. Water repellent (hydrophobic) properties of composite insulators, light weight, resistance to vandalism are among the main reasons for their usage. This has been proven by positive outcomes of numerous studies performed in laboratory and field conditions [8,9,13-16]. However, due to exposure to harsh service stresses such as corona discharges, UV radiation and chemical attacks etc., the housing materials may lose hydrophobic properties and develop surface degradation (tracking, erosion). In addition to the ever-increasing use of composite insulators, polymeric coatings (mainly RTV silicone rubber) [17] and semi-conducting glazes [18] have also been adopted for improving performance of ceramic and glass insulators [19].

1 December 2008
Verified
Conference Paper
Closed access
SRS. Ranawana
S. Ranawana
CEC.M.B. Ekanayaka
C.M.B. Ekanayaka
NKN.A.S.A. Kurera
N.A.S.A. Kurera
Manjula FernandoManjula Fernando
Manjula Fernando
KPK.A.R. Perera
K.A.R. Perera
This paper presents the experimental results of a study, which has been carried out to analyze the insulation characteristics of coconut oil in order to check the suitability as the liquid insulation in power transformers. In this study dielectric response measurements were carried out in frequency domain at temperatures of 25degC, 50degC, 80degC. In addition, results of mineral oil samples were taken for comparison. Further, breakdown voltage was also measured on samples. Based on the results, relative permittivity and conductivity values were obtained at room temperature (25degC) and elevated temperatures. Finally, the activation energy values were calculated on each sample. The dielectric breakdown voltages of the five coconut oil samples were in the range of 9.3 kV to 18.4 kV, which should be above 50 kV according to the IEC60296 standard. Conductivity values of coconut oil at room temperature were in a range from 10-11 to 10-12 S, which is considerably higher than that of new mineral oil. These results imply that further purification is required to bring coconut oil to the required standard to use as an insulating medium in transformers. Effort was done to identify the effect of temperature on dielectric response measurements of oil insulation system and correlation of it with the conductivity. The activation energy of five coconut oil samples was around 0.1, which is less than that of mineral oil, i.e. 0.4. This implies that the increase of conductivity with temperature is considerably low in coconut oil, when comparing with mineral oil.

21 December 2020 in IEEE Access
Verified
Journal Article
Open access
SVSrinivasan Venkatesh
Srinivasan Venkatesh
Manjula FernandoManjula Fernando
Manjula Fernando
SKSarath Kumara
Sarath Kumara
TSThirumalini Selvaraj
Thirumalini Selvaraj
Vernon CoorayVernon Cooray
Vernon Cooray
Lightning is one of the inevitable disastrous phenomena which in addition to damaging tall edifices, might also consequently endanger humans due to lightning-human interactions. This research focuses on analyzing lightning hazards to humans in the vicinity of heritage monuments in India and Sri Lanka. Five monuments which include three giant stupas namely Ruwanweliseya, Jethawanaramaya and Abayagiriya from Sri Lanka and two large temples namely Brihadishvara Temple and Gangaikonda Cholapuram from India have been chosen for investigation. Lightning-human interaction mechanisms namely direct strike, side flash, aborted upward leader, step and touch voltages have been investigated for the most onerous scenario on humans in the vicinity of the monuments. Firstly, the electro-geometric model as stipulated in standards has been implemented to ascertain the effectiveness of lightning protection to the structures. Subsequently, the study has been extended to the computation of step and touch voltages utilizing lightning current and electrostatic models based on Finite Element Method (FEM) using COMSOL Multi-physics ® . Detailed plots of electric field and voltage distribution of lightning on humans due to a typical lightning current of 30 kA have been obtained. The final study involves assessment of current through humans which is estimated based on lumped R-C human model representation using OrCAD Cadence ® . The analyses reveal that humans are invariably shielded against direct strikes whereas effects due to side flashes are minimal. During strikes to the monuments, high voltage may appear due to step and touch potential under dry conditions, though such effects could be mitigated by appropriate earthing system.

2 September 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
TSTHIRUMALINI SELVARAJ
THIRUMALINI SELVARAJ
VSVENKATESH SRINIVASAN
VENKATESH SRINIVASAN
SRSimona Raneri
Simona Raneri
Manjula FernandoManjula Fernando
Manjula Fernando
Kunal KakriaKunal Kakria
Kunal Kakria
SJSimon Jayasingh
Simon Jayasingh
Lightning strikes are prevalent and inevitable natural phenomena that might cause damages during interaction with building structures and, in some cases, culminate in fires. During the last decades, several lightning strikes have caused considerable damages to cultural and heritage buildings. Furthermore, recent studies indicated a plausible connection between climate changes due to global warming and variations in the frequency and intensity of lightning. The evaluation of the structural efficiency and resilience of cultural buildings to global changes and natural risks appears significant in the light of the current scientific debate. This research aims at the assessment of lightning strikes’ effects on ancient heritage binding materials through the characterization of their thermal and electrical conductivity properties. This study focused on the performance evaluation of green and low-cost mortars based on the use of organic additives. Lime samples were reverse engineered by using a mixture of organics (fig, jaggery, black grape, banana, kadukai), which comprises the most common additives used in traditional Indian mortars. The reliability of the organic mixture in enhancing the resilience of masonry to lightning strikes was analyzed by using electromagnetic field simulation.

1 October 2012
Verified
Conference Paper
Closed access
SMShanika Matharage
Shanika Matharage
Manjula FernandoManjula Fernando
Manjula Fernando
ETEnis Tuncer
Enis Tuncer
MBM. A. A. P. Bandara
M. A. A. P. Bandara
CKC. S. Kalpage
C. S. Kalpage
This paper presents performance comparison of coconut oil as an alternative liquid insulation for transformer mineral oil during ageing and under simulated electrical and thermal fault conditions. In the ageing study, 6 wet coconut oil, 6 wet and 6 dry transformer oil samples were aged (each half as sealed and unsealed with inclusions of Cu, Al, Fe and Zn metal substances) inside an oven at 120°C. Six sample sets were taken out at three different ageing intervals i.e. 2, 5 and 7 weeks and were tested by visual inspection (color), chemical tests (interfacial tension, acidity, DGA) and electrical tests (breakdown voltage, FDS). In the electrical fault study, 2 coconut oil and 2 transformer oil samples were exposed to corona for four hours and for 20 electrical breakdowns with a point-plane gap of 15mm. In the thermal fault study, 2 coconut oil and 2 transformer oil samples were aged at 160°C for 12 hours and at 200°C for 1 hour. The DGA and FDS measurements were taken on the aged samples. FDS Results were analyzed by using Davidson-Cole Model. It was found that the coconut oil samples gave comparable results with those for transformer oil.

12 December 2021
Verified
Conference Paper
Closed access
TWTharaka Wijethunge
Tharaka Wijethunge
PTPawara Tharkana
Pawara Tharkana
AWAmila Wimalaweera
Amila Wimalaweera
JWJanaka Wijayakulasooriya
Janaka Wijayakulasooriya
SKSarath Kumara
Sarath Kumara
Manjula FernandoManjula Fernando
Manjula Fernando
This paper presents a machine learning approach for estimation of moisture content (MC) in power transformer insulation based on its frequency domain dielectric spectroscopy (FDS). The proposed method is based on principal component analysis and support vector machine approaches. It classifies transformer insulation into three classes based on the estimated MC levels i.e. dry (MC<1%), intermediate (1%<MC3%). The proposed algorithm was trained and tested using FDS data sets consisting of 112 laboratory modeled samples and 20 field transformer samples. The laboratory modeled data were estimated using XY model from FDS measurements on pressboard samples having different moisture levels. A range of transformer geometries, aging conditions of pressboard and oil conductivities were considered when deriving the data set. The results showed that the moisture classification was accurate up to 96% thus indicating as a simple and promising method for transformer moisture estimation.