Costas Kokolakis

Mr. Costas Kokolakis


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Stelios MertikasStelios Mertikas
Stelios Mertikas
ATAchilleas Tripolitsiotis
Achilleas Tripolitsiotis
CDCraig Donlon
Craig Donlon
CMConstantin Mavrocordatos
Constantin Mavrocordatos
Pierre FemeniasPierre Femenias
Pierre Femenias
RCRobert Cullen
Robert Cullen
This work presents the latest calibration results for the Copernicus Sentinel-3A and -3B and the Jason-3 radar altimeters as determined by the Permanent Facility for Altimetry Calibration (PFAC) in west Crete, Greece. Radar altimeters are used to provide operational measurements for sea surface height, significant wave height and wind speed over oceans. To maintain Fiducial Reference Measurement (FRM) status, the stability and quality of altimetry products need to be continuously monitored throughout the operational phase of each altimeter. External and independent calibration and validation facilities provide an objective assessment of the altimeter’s performance by comparing satellite observations with ground-truth and in-situ measurements and infrastructures. Three independent methods are employed in the PFAC: Range calibration using a transponder, sea-surface calibration relying upon sea-surface Cal/Val sites, and crossover analysis. Procedures to determine FRM uncertainties for Cal/Val results have been demonstrated for each calibration. Biases for Sentinel-3A Passes No. 14, 278 and 335, Sentinel-3B Passes No. 14, 71 and 335, as well as for Jason-3 Passes No. 18 and No. 109 are given. Diverse calibration results by various techniques, infrastructure and settings are presented. Finally, upgrades to the PFAC in support of the Copernicus Sentinel-6 ‘Michael Freilich’, due to launch in November 2020, are summarized.

12 August 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Stelios MertikasStelios Mertikas
Stelios Mertikas
Panagiotis PartsinevelosPanagiotis Partsinevelos
Panagiotis Partsinevelos
ATAchilleas Tripolitsiotis
Achilleas Tripolitsiotis
CKCostas Kokolakis
Costas Kokolakis
GPGeorgios Petrakis
Georgios Petrakis
XFXenophon Frantzis
Xenophon Frantzis
Water vapor is one of the essential variables in monitoring the Earth’s climate. The Ocean and Land Color Instrument (OLCI) on-board the Copernicus Sentinel-3 missions measures the Integrated Water Vapor (IWV) column over land and ocean surfaces. Post-launch calibration and validation of satellite measurements constitutes a key process in the operational phase of Earth observation satellites. This work presents the external and independent validation of OLCI-A IWV product using the regional network of continuously operating Global Navigation Satellite System (GNSS) comprised 10 stations distributed over the island of Crete in the eastern Mediterranean. The Sentinel-3A/-3B OLCI imagery that captures in a single scene the entire area of Crete has been examined. For each OLCI image, the IWV value of cloud-free pixels containing the GNSS stations have been derived and compared against simultaneous GNSS-derived measurements. The absolute as well as the relative bias between OLCI-A and OLCI-B IWV measurements have been determined. There is a good agreement between OLCI and GNSS with a bias of −0.57 mm ± 2.90 mm for OLCI(A) and +2.42 ± 3.41 mm for OLCI(B). The results of this regional validation activity are compared against other studies and the regular validation carried out at the Sentinel-3 Mission Performance Center. This work concludes that the accuracy of the OLCI IWV products is within its design requirements. The potential synergy between Sentinel-2 and Sentinel-3 IWV products is also discussed.

15 November 2018 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Stelios MertikasStelios Mertikas
Stelios Mertikas
CDCraig Donlon
Craig Donlon
Pierre FemeniasPierre Femenias
Pierre Femenias
CMConstantin Mavrocordatos
Constantin Mavrocordatos
DGDemitris Galanakis
Demitris Galanakis
TGThierry Guinle
Thierry Guinle
This work presents calibration results for the altimeter of Sentinel-3A Surface Topography Mission as determined at the Permanent Facility for Altimetry Calibration in west Crete, Greece. The facility has been providing calibration services for more than 15 years for all past (i.e., Envisat, Jason-1, Jason-2, SARAL/AltiKa, HY-2A) and current (i.e., Sentinel-3A, Sentinel-3B, Jason-3) satellite altimeters. The groundtrack of the Pass No.14 of Sentinel-3A ascends west of the Gavdos island and continues north to the transponder site on the mountains of west Crete. This pass has been calibrated using three independent techniques activated at various sites in the region: (1) the transponder approach for its range bias, (2) the sea-surface method for the estimation of altimeter bias for its sea-surface heights, and (c) the cross-over analysis for inspecting height observations with respect to Jason-3. The other Pass No.335 of Sentinel-3A descends from southwest of Crete to south and intersects the Gavdos calibration site. Additionally, calibration values for this descending pass are presented, applying sea-surface calibration and crossover analysis. An uncertainty analysis for the altimeter biases derived by the transponder and by sea-surface calibrations is also introduced following the new standard of Fiducial Reference Measurements.