Dariusz Ksionek

Dr. Dariusz Ksionek

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Energy and Buildings
Verified
Journal Article
Closed access
LBLorenza Bianco
Lorenza Bianco
AKAnna Komerska
Anna Komerska
YCYlenia Cascone
Ylenia Cascone
Valentina SerraValentina Serra
Valentina Serra
MZMichele Zinzi
Michele Zinzi
DKDariusz Ksionek
Dariusz Ksionek

7 November 2017 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
AKAnna Komerska
Anna Komerska
DKDariusz Ksionek
Dariusz Ksionek
MRMarian Rosiński
Marian Rosiński
This article presents results of the energy performance of an external translucent shading component integrated with a phase change material. A proposed technology is able to accumulate considerable amounts of energy in the latent heat by absorbing solar energy. Due to selective optical properties, much of the visible light is still transmitted through the facade. Experimental measurements were carried out in a laboratory set–up – testing thermal chamber, located in the Faculty of Building Services, Hydro and Environmental Engineering at Warsaw University of Technology. The main result of the experimental study was the evaluation of the average solar transmittance in the whole measured spectrum, as well as in the infrared and visible light. Since the shift in optical properties was observed when the material was undergoing a phase transition, the average spectral transmittances were measured for different states of matter of the PCM material. The tested shutter showed abilities to reduce and modulate daylight and solar heat gains in the indoor environment, which could contribute to considerable energy savings.

18 November 2025 in Chemengineering
Verified
Journal Article
Open access
PDF file
MSMichał Sobieraj
Michał Sobieraj
DKDariusz Ksionek
Dariusz Ksionek
MKMichał Kamiński
Michał Kamiński
FKFilip Karczmarczyk
Filip Karczmarczyk
The application range of a two-phase loop thermosyphon (TPLT) includes electronics cooling and heating and ventilation (HVAC) systems. Combining data center heat removal with HVAC systems can be beneficial in terms of reducing energy use and greenhouse gas emissions. The thermal resistance of the TPLT is the most important parameter affecting its heat transfer ability. This study presents the first experimental characteristics of the TPLT, working with novel low Global Warming Potential (GWP) fluids, including the evaporating and condensing performance. The operation of the TPLT is evaluated with pure fluids R600a, R32, and their mixture R600a/R32 at heat sink temperature in the range of 25 °C to 35 °C under heat input from 50 W to 225 W. The novel mixture presents the highest temperature at the evaporator outlet. Pure fluids R600a and R32 show the highest heat transfer coefficients and the lowest thermal resistance. The flow visualization is performed to study the boiling flow patterns. Empirical correlations are employed to predict the boiling-heat transfer coefficients. Thermal characteristics are obtained for further development of TPLT operating with environmentally friendly fluids.