Michał Sobieraj

Dr. Michał Sobieraj

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
MSMichał Sobieraj
Michał Sobieraj
An experimental evaluation of an autocascade refrigeration (ACR) system was carried out. A zeotropic mixture of isobutane and CO2 was employed as a working fluid in an autocascade refrigeration (ACR) system. An experimental system was designed and built to study the influence of the recuperative heat exchanger (RHX) and openings of the throttle valves on the system performance. The use of RHX facilitated the condensation process and improved the cycle characteristics. The working mass concentration of CO2 was higher, as it was closer to the nominal concentration and the discharge pressure was lower by 19% to even 39% when the RHX was employed in the system. An increase of up to 20% in the coefficient of performance (COP) was observed. Furthermore, the effects of the openings of the throttle valves on the system characteristics were studied. The change in the openings of the expansion valves affected the mass flows and the working mixture composition. The working CO2 mass fraction increased with higher openings of the evaporator throttle. The subcooling degree of liquid CO2-rich refrigerant increased with higher openings of the expansion valve under the phase separator. The results of the present work should be helpful for design and optimization of autocascade systems working with natural and synthetic refrigerants.

1 July 2019 in International Journal of Refrigeration
Verified
Journal Article
Closed access
MSMichał Sobieraj
Michał Sobieraj
MRMarian Rosiński
Marian Rosiński

18 November 2025 in Chemengineering
Verified
Journal Article
Open access
PDF file
MSMichał Sobieraj
Michał Sobieraj
DKDariusz Ksionek
Dariusz Ksionek
MKMichał Kamiński
Michał Kamiński
FKFilip Karczmarczyk
Filip Karczmarczyk
The application range of a two-phase loop thermosyphon (TPLT) includes electronics cooling and heating and ventilation (HVAC) systems. Combining data center heat removal with HVAC systems can be beneficial in terms of reducing energy use and greenhouse gas emissions. The thermal resistance of the TPLT is the most important parameter affecting its heat transfer ability. This study presents the first experimental characteristics of the TPLT, working with novel low Global Warming Potential (GWP) fluids, including the evaporating and condensing performance. The operation of the TPLT is evaluated with pure fluids R600a, R32, and their mixture R600a/R32 at heat sink temperature in the range of 25 °C to 35 °C under heat input from 50 W to 225 W. The novel mixture presents the highest temperature at the evaporator outlet. Pure fluids R600a and R32 show the highest heat transfer coefficients and the lowest thermal resistance. The flow visualization is performed to study the boiling flow patterns. Empirical correlations are employed to predict the boiling-heat transfer coefficients. Thermal characteristics are obtained for further development of TPLT operating with environmentally friendly fluids.