Douglas Renaux

Prof. Dr. Douglas Renaux

UTFPR - Universidade Tecnológica Federal do Paraná
+1

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
DRDouglas Renaux
Douglas Renaux
FPFabiana Pottker
Fabiana Pottker
HAHellen Cristina Ancelmo
Hellen Cristina Ancelmo
André Eugênio LazzarettiAndré Eugênio Lazzaretti
André Eugênio Lazzaretti
CLCarlos Raiumundo Erig Lima
Carlos Raiumundo Erig Lima
RSRodrigo Braun dos Santos
Rodrigo Braun dos Santos
A NILM dataset is a valuable tool in the development of Non-Intrusive Load Monitoring techniques, as it provides a means of evaluation of novel techniques and algorithms, as well as for benchmarking. The figure of merit of a NILM dataset includes characteristics such as the sampling frequency of the voltage, current, or power, the availability of indications (ground-truth) of load events during recording, the variety and representativeness of the loads, and the variety of situations these loads are subject to. Considering such aspects, the proposed LIT-Dataset was designed, populated, evaluated, and made publicly available to support NILM development. Among the distinct features of the LIT-Dataset is the labeling of the load events at sample level resolution and with an accuracy and precision better than 5 ms. The availability of such precise timing information, which also includes the identification of the load and the sort of power event, is an essential requirement both for the evaluation of NILM algorithms and techniques, as well as for the training of NILM systems, particularly those based on Machine Learning.

4 August 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BMBruna Machado Mulinari
Bruna Machado Mulinari
LNLucas da Silva Nolasco
Lucas da Silva Nolasco
EOElder Oroski
Elder Oroski
André Eugênio LazzarettiAndré Eugênio Lazzaretti
André Eugênio Lazzaretti
RLRobson Ribeiro Linhares
Robson Ribeiro Linhares
DRDouglas Renaux
Douglas Renaux
Nonintrusive load monitoring (NILM) techniques allow the individual consumption of devices in an installation to be reported to the user, collaborating in the awareness and managing consumers’ energy use. One of the most critical steps in NILM procedures is feature extraction, which involves the quantitative description of the load signature. Most state-of-the-art methods, particularly those involving voltage–current ( V–I ) trajectories, are based on features that specialists design when manually analyzing signals—the so-called hand-crafted features. On the other hand, this work presents a mathematical method that describes the transient and steady-state (SS) load signature using a 2-D Fourier series, avoiding hand-crafted descriptors. The proposed approach evaluates load identification results with different classifiers and publicly available datasets. In addition to the evaluation of the proposed method’s computational resources, such as execution time and memory footprint in an embedded system, their robustness to noise insertion is also assessed. The results of the proposed approach indicate an average per-class accuracy higher than 90%, equivalent or superior to hand-crafted V–I trajectory-based methods in most cases and even deep learning approaches recently presented in the literature. Such results reinforce the main contributions of this work: 1) a mathematical method to extract interpretable features; 2) results comparable or superior to other state-of-the-art methods; and 3) promising results in computational resources in an embedded system.

26 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
André Eugênio LazzarettiAndré Eugênio Lazzaretti
André Eugênio Lazzaretti
DRDouglas Renaux
Douglas Renaux
CLCarlos Raimundo Erig Lima
Carlos Raimundo Erig Lima
BMBruna Machado Mulinari
Bruna Machado Mulinari
HAHellen Cristina Ancelmo
Hellen Cristina Ancelmo
RSRodrigo Braun dos Santos
Rodrigo Braun dos Santos
A multi-agent architecture for a Non-Intrusive Load Monitoring (NILM) solution is presented and evaluated. The underlying rationale for such an architecture is that each agent (load event detection, feature extraction, and classification) outperforms others of the same type in particular scenarios; hence, by combining the expertise of these agents, the system presents an improved performance. Known NILM algorithms, as well as new algorithms, proposed by the authors, were individually evaluated and compared. The proposed architecture considers a NILM system composed of Load Monitoring Modules (LMM) that report to a Center of Operations, required in larger facilities. For the purposed of evaluating and comparing performance, five load event detect agents, five feature extraction agents, and five classification agents were studied so that the best combinations of agents could be implemented in LMMs. To evaluate the proposed system, the COOLL and the LIT-Dataset were used. Performance improvements were detected in all scenarios, with power-ON and power-OFF detection improving up to 13%, while classification accuracy improved up to 9.4%.

21 May 2025 in IEEE Access
Verified
Journal Article
Open access
GPGabrielly de Queiroz Pereira
Gabrielly de Queiroz Pereira
DRDouglas Renaux
Douglas Renaux
André Eugênio LazzarettiAndré Eugênio Lazzaretti
André Eugênio Lazzaretti
Irrigation optimization in horticulture is highly relevant due to the high sensitivity of crops to water availability. Methods such as Reinforcement Learning (RL) and Rule-Based Systems (RBS) have been explored for automated irrigation; however, direct comparisons between these approaches for horticultural crops remain limited. This study compares RL and RBS for optimizing irrigation in lettuce cultivation using the AquaCrop-OSPy model. A Q-Learning RL agent dynamically adjusts irrigation decisions based on a customized reward function, while the RBS applies predefined water balance rules. Simulations were conducted over 30 days in each of the four seasons. Results indicate that RL achieved an average dry yield of 5.84 tonne/ha with 186.25 mm of water, while RBS produced 2.35 tonne/ha with 92.01 mm. RL consistently delivered higher productivity but at the cost of increased water use, whereas RBS demonstrated greater water efficiency under conservative irrigation strategies. The findings highlight RL’s adaptability to varying conditions and RBS’s reliability for water-limited scenarios. Future research can explore hybrid systems that integrate RL’s flexibility with RBS’s efficiency. The code and datasets are available at https://github.com/GabyQueiroz/RBS_RL_Irrigation

1 May 2024 in Retos
Verified
Journal Article
Open access
PDF file
LPLuiz Alberto Pilatti
Luiz Alberto Pilatti
GPGabrielly de Queiroz Pereira
Gabrielly de Queiroz Pereira
JCJosé Roberto Herrera Cantorani
José Roberto Herrera Cantorani
LLLuiz Marcelo De Lara
Luiz Marcelo De Lara
DRDouglas Renaux
Douglas Renaux
The present study aims to analyze the management actions adopted by the Real Madrid club through the lens of the Four Actions Framework of the Blue Ocean Strategy. It is a systematic literature review using the methodology Methodi Ordinatio and employs content analysis as the analytical approach. Searches were conducted in the Web of Science, Science Direct, and Scopus databases in May 2023. The research portfolio included 19 articles. The analytical content analysis procedure was carried out using NVivo Pro 14 software. Applying the Blue Ocean Four Actions Framework provided insights into Real Madrid's management strategies and business success. The findings illuminate various aspects of Real Madrid's operations, encompassing website structure, values, communication strategies, management approaches, financial performance, and areas for potential enhancement. Keywords: Blue Ocean Four Actions Framework, Real Madrid club de fútebol, management strategies, soccer club management.