Recent oncological studies identified beneficial properties of radiation applied at ultrahigh dose rates, several orders of magnitude higher than the clinical standard of the order of Gy min–1. Sources capable of providing these ultrahigh dose rates are under investigation. Here we show that a stable, compact laser-driven proton source with energies greater than 60 MeV enables radiobiological in vivo studies. We performed a pilot irradiation study on human tumours in a mouse model, showing the concerted preparation of mice and laser accelerator, dose-controlled, tumour-conform irradiation using a laser-driven as well as a clinical reference proton source, and the radiobiological evaluation of irradiated and unirradiated mice for radiation-induced tumour growth delay. The prescribed homogeneous dose of 4 Gy was precisely delivered at the laser-driven source. The results demonstrate a complete laser-driven proton research platform for diverse user-specific small animal models, able to deliver tunable single-shot doses up to around 20 Gy to millimetre-scale volumes on nanosecond timescales, equivalent to around 109 Gy s–1, spatially homogenized and tailored to the sample. The platform provides a unique infrastructure for translational research with protons at ultrahigh dose rates.
Laser-driven ion accelerators can deliver high-energy, high-peak current beams and are thus attracting attention as a compact alternative to conventional accelerators. However, achieving sufficiently high energy levels suitable for applications such as radiation therapy remains a challenge for laser-driven ion accelerators. Here we generate proton beams with a spectrally separated high-energy component of up to 150 MeV by irradiating solid-density plastic foil targets with ultrashort laser pulses from a repetitive petawatt laser. The preceding laser light heats the target, leading to the onset of relativistically induced transparency upon main pulse arrival. The laser peak then penetrates the initially opaque target and triggers proton acceleration through a cascade of different mechanisms, as revealed by three-dimensional particle-in-cell simulations. The transparency of the target can be used to identify the high-performance domain, making it a suitable feedback parameter for automated laser and target optimization to enhance stability of plasma accelerators in the future.
We report on recent experimental results deploying a continuous cryogenic hydrogen jet as a debris-free, renewable laser-driven source of pure proton beams generated at the 150 TW ultrashort pulse laser Draco. Efficient proton acceleration reaching cut-off energies of up to 20 MeV with particle numbers exceeding 109 particles per MeV per steradian is demonstrated, showing for the first time that the acceleration performance is comparable to solid foil targets with thicknesses in the micrometer range. Two different target geometries are presented and their proton beam deliverance characterized: cylindrical (∅ 5 μm) and planar (20 μm × 2 μm). In both cases typical Target Normal Sheath Acceleration emission patterns with exponential proton energy spectra are detected. Significantly higher proton numbers in laser-forward direction are observed when deploying the planar jet as compared to the cylindrical jet case. This is confirmed by two-dimensional Particle-in-Cell (2D3V PIC) simulations, which demonstrate that the planar jet proves favorable as its geometry leads to more optimized acceleration conditions.
We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.
Laser plasma-based particle accelerators attract great interest in fields where conventional accelerators reach limits based on size, cost or beam parameters. Despite the fact that particle in cell simulations have predicted several advantageous ion acceleration schemes, laser accelerators have not yet reached their full potential in producing simultaneous high-radiation doses at high particle energies. The most stringent limitation is the lack of a suitable high-repetition rate target that also provides a high degree of control of the plasma conditions required to access these advanced regimes. Here, we demonstrate that the interaction of petawatt-class laser pulses with a pre-formed micrometer-sized cryogenic hydrogen jet plasma overcomes these limitations enabling tailored density scans from the solid to the underdense regime. Our proof-of-concept experiment demonstrates that the near-critical plasma density profile produces proton energies of up to 80 MeV. Based on hydrodynamic and three-dimensional particle in cell simulations, transition between different acceleration schemes are shown, suggesting enhanced proton acceleration at the relativistic transparency front for the optimal case.
Motivated by the development of next-generation heavy-ion sources, we have investigated the ionization and acceleration dynamics of an ultraintense laser-driven high- silver target, experimentally, numerically, and analytically. Using a novel ion measurement technique allowing us to uniquely identify silver ions, we experimentally demonstrate generation of highly charged silver ions () with energies of MeV/nucleon ( GeV) from submicron silver targets driven by a laser with intensity , with increasing ion energy and charge state for decreasing target thickness. We show that although target pre-expansion by the unavoidable rising edge of state-of-the-art high-power lasers can limit proton energies, it is advantageous for heavy-ion acceleration. Two-dimensional particle-in-cell simulations show that the Joule heating in the target bulk results in a high temperature () solid density plasma, leading to the generation of high flux highly charged ions (, ) via electron collisional ionization, which are extracted and accelerated with a small divergence by an extreme sheath field at the target rear. However, with reduced target thickness this favorable acceleration is degraded due to the target deformation via laser hole boring, which accompanies higher energy ions with higher charge states but in an uncontrollable manner. Our elucidation of the fundamental processes of high-intensity laser-driven ionization and ion acceleration provides a path for improving the control and parameters of laser-driven heavy-ion sources, a key component for next-generation heavy-ion accelerators.