Li Shi

Dr. Li Shi

School of Mechanical Engineering and Mechanics, Xiangtan University, Xiangtan, Hunan, China
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Li ShiLi Shi
Li Shi
ZSZhiying Sun
Zhiying Sun
YLYuanfeng Lu
Yuanfeng Lu
This paper presents a numerical investigation on the combined influences of film cooling and thermal barrier coatings (TBCs) on the cooling performances of a NASA C3X guide vane. The results show that: (1) film cooling on the pressure side is more effective than suction side, especially on the trailing edge where multiple cooling and thermal protection techniques include internal cooling and TBCs are necessary. (2) TBCs show positive and negative roles in improving cooling performance at the same time for the coated vane with or without film cooling. Without film cooling, TBCs show negative roles on the regions with lower temperature external hot gas, which is caused by flow acceleration from the stagnation line of the suction side. (3) Internal cooling improvement caused by coolant introduction leads to a larger cooling effectiveness inclement due to TBCs near coolant plenums and film cooling holes. However, the influence of TBCs on cooling effectiveness increment goes down and even shows negative roles on the regions away from coolant plenums and under the effective coverage of the film cooling. (4) Improving the convective heat transfer of coolant with the wall of coolant plenums and film cooling holes is the guarantee of improving the cooling performance of a coated vane.

22 July 2024 in Journal of Cardiovascular Translational Research
Verified
Journal Article
Open access
PDF file
LLLongyan Li
Longyan Li
Li ShiLi Shi
Li Shi
XTXiao Tan
Xiao Tan
YZYixia Zhao
Yixia Zhao
A left ventricular assist device (LVAD) supports hemodynamics in heart failure patients. To deepen the understanding of hemodynamic changes and the movement of thrombi in the aorta, we examined three distinct LVAD blood flow rates across two implantation sites using the theory of computational fluid dynamics. Our findings revealed the complex dynamics of blood flow during cardiac systole under various scenarios. We also analyzed thrombi residence time and flow probabilities into aortic branches. Simulation results indicate that thrombi distribution in the aorta is significantly influenced by the location of the LVAD outflow graft and the flow rate. When the LVAD outflow graft is implanted into the ascending aorta, higher flow rates may reduce the risk of cerebral thrombosis. However, lower flow rates may reduce the risk of cerebral thrombosis while it is implanted into the descending aorta. The study may offer valuable insights into the LVAD implantation about the risk of cerebrovascular embolism. Graphical Abstract

11 January 2025 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
Li ShiLi Shi
Li Shi
CWChangce Wang
Changce Wang
XTXiao Tan
Xiao Tan
RDRongli Deng
Rongli Deng
JSJiasheng Song
Jiasheng Song
JPJinfeng Peng
Jinfeng Peng

28 January 2025 in International Journal of Heat and Fluid Flow
Verified
Journal Article
Closed access
XTXiao Tan
Xiao Tan
Li ShiLi Shi
Li Shi
RDRongli Deng
Rongli Deng
LSLiang Su
Liang Su
JPJinfeng Peng
Jinfeng Peng
JCJunjie Chen
Junjie Chen

9 June 2021 in Coatings
Verified
Journal Article
Open access
PDF file
Li ShiLi Shi
Li Shi
HHHanze Huang
Hanze Huang
YLYuanfeng Lu
Yuanfeng Lu
SXShunsheng Xu
Shunsheng Xu
CGChen Ge
Chen Ge
This paper studied the combined influences of the hot streak and swirl on the cooling performances of the NASA C3X guide vane coated with or without thermal barrier coatings (TBCs). The results show that: (1) Even under uniform velocity inlet conditions, the hot streak core can be stretched as it impinges the leading edge which causes higher heat load on the suction side of the forward portion. (2) The swirl significantly affects circumferential and radial migration of the hot streak core in the NGV passage. On the passage inlet plane, positive swirl leads to a hotter tip region on the suction side. In comparison, negative swirl leads to a hotter hub region on the pressure side. (3) Under the influence of swirl, migration of coolant improves the coverage of film cooling close to the midspan, while in the regions close to the hub and tip end-wall, the overall cooling performance decreases simultaneously. (4) In the regions with enough internal cooling, the cooling effectiveness increment is always larger than that in other regions. Besides, the overall cooling effectiveness increment decreases on the region covered by film cooling for the coated vane, especially in the region with negative local heat flux.

23 March 2026 in International Journal of Thermal Sciences
Verified
Journal Article
Closed access
Li ShiLi Shi
Li Shi
HZHaoyu Zhang
Haoyu Zhang
XTXiao Tan
Xiao Tan
CWChangce Wang
Changce Wang
YLYue Luo
Yue Luo
JSJiasheng Song
Jiasheng Song