This paper presents a numerical investigation on the combined influences of film cooling and thermal barrier coatings (TBCs) on the cooling performances of a NASA C3X guide vane. The results show that: (1) film cooling on the pressure side is more effective than suction side, especially on the trailing edge where multiple cooling and thermal protection techniques include internal cooling and TBCs are necessary. (2) TBCs show positive and negative roles in improving cooling performance at the same time for the coated vane with or without film cooling. Without film cooling, TBCs show negative roles on the regions with lower temperature external hot gas, which is caused by flow acceleration from the stagnation line of the suction side. (3) Internal cooling improvement caused by coolant introduction leads to a larger cooling effectiveness inclement due to TBCs near coolant plenums and film cooling holes. However, the influence of TBCs on cooling effectiveness increment goes down and even shows negative roles on the regions away from coolant plenums and under the effective coverage of the film cooling. (4) Improving the convective heat transfer of coolant with the wall of coolant plenums and film cooling holes is the guarantee of improving the cooling performance of a coated vane.
This paper studied the combined influences of the hot streak and swirl on the cooling performances of the NASA C3X guide vane coated with or without thermal barrier coatings (TBCs). The results show that: (1) Even under uniform velocity inlet conditions, the hot streak core can be stretched as it impinges the leading edge which causes higher heat load on the suction side of the forward portion. (2) The swirl significantly affects circumferential and radial migration of the hot streak core in the NGV passage. On the passage inlet plane, positive swirl leads to a hotter tip region on the suction side. In comparison, negative swirl leads to a hotter hub region on the pressure side. (3) Under the influence of swirl, migration of coolant improves the coverage of film cooling close to the midspan, while in the regions close to the hub and tip end-wall, the overall cooling performance decreases simultaneously. (4) In the regions with enough internal cooling, the cooling effectiveness increment is always larger than that in other regions. Besides, the overall cooling effectiveness increment decreases on the region covered by film cooling for the coated vane, especially in the region with negative local heat flux.
Hot streaks and rotor–stator interaction have a great influence on the aerothermal performance of turbine blades. Previous investigations have conducted limited study of the film-cooled blade. To investigate the combined effects of a hot streak and rotor–stator interaction on the coated blade, an unsteady numerical simulation has been conducted with an efficient unsteady Navier–Stokes solver in this paper. The numerical results at four different relative stator–rotor locations (t = 0/4 T, 1/4 T, 2/4 T, and 3/4 T) have been investigated in one stator period. Compared with the stator, rotor–stator interaction exerts a significant impact on the cooling performance of the rotor blade under hot streak inlet conditions. The overall cooling effectiveness distribution of the coated rotor blade is similar to that of the uncoated blades in one stator period. Relatively lower overall cooling performance of the rotor blade can be observed in the 1/4 stator period. Then, the cooling performance begins to increase and relatively larger cooling effectiveness can be observed in the 3/4 stator period. The addition of a TBC is generally beneficial to the improvement of blade surface cooling performance, especially for the areas with low overall cooling performance. However, a negative cooling effectiveness increment can be observed at the trailing edge. It shows that for an area with poor cooling performance, the addition of thermal barrier coating will have the opposite effect. Therefore, it is necessary to enhance the design of cooling arrangements at the trailing edge to maximize the insulation performance of TBCs for the coated rotor blade.
The influence of the HS (hot streak) and unsteady wake on the overall cooling performance of a rotor blade was studied in this paper. The results show that: (1) Both the magnitude and temperature of the HS gradually drops down as it passes downstream of the vane passage. (2) Within one stator period, the highest cooling performance of the blade can be observed at the initial time points, when the LE (leading edge) of the blade turns towards the trailing edge of the vane. (3) The lowest cooling performance of the blade can be observed at the time point 0.5 T, when the LE of the blade turns towards the center of the vane passage. (4) Surface temperatures in areas with unfavorable local heat flow are usually higher than the temperature of the coolant. The additional TBCs may exert adverse effects on heat dissipation from the substrate metal to the mainstream, which has a negative effect on the improvement of the overall cooling effectiveness of the coated blade. (5) Within a stator period, a relatively higher overall cooling effectiveness increment due to the coating can be observed at the relative location with lower cooling performance. Consequently, the additional TBCs are beneficial for decreasing the surface temperature difference and thus controlling the thermal stress under the HS inlet condition.