Vasileios Christou

Dr. Vasileios Christou

University of Ioannina
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Evangelos AntoniouEvangelos Antoniou
Evangelos Antoniou
PBPavlos Bozios
Pavlos Bozios
Vasileios ChristouVasileios Christou
Vasileios Christou
Katerina D. TzimourtaKaterina D. Tzimourta
Katerina D. Tzimourta
Konstantinos KalafatakisKonstantinos Kalafatakis
Konstantinos Kalafatakis
Alexandros T TzallasAlexandros T Tzallas
Alexandros T Tzallas
Discrimination of eye movements and visual states is a flourishing field of research and there is an urgent need for non-manual EEG-based wheelchair control and navigation systems. This paper presents a novel system that utilizes a brain–computer interface (BCI) to capture electroencephalographic (EEG) signals from human subjects while eye movement and subsequently classify them into six categories by applying a random forests (RF) classification algorithm. RF is an ensemble learning method that constructs a series of decision trees where each tree gives a class prediction, and the class with the highest number of class predictions becomes the model’s prediction. The categories of the proposed random forests brain–computer interface (RF-BCI) are defined according to the position of the subject’s eyes: open, closed, left, right, up, and down. The purpose of RF-BCI is to be utilized as an EEG-based control system for driving an electromechanical wheelchair (rehabilitation device). The proposed approach has been tested using a dataset containing 219 records taken from 10 different patients. The BCI implemented the EPOC Flex head cap system, which includes 32 saline felt sensors for capturing the subjects’ EEG signals. Each sensor caught four different brain waves (delta, theta, alpha, and beta) per second. Then, these signals were split in 4-second windows resulting in 512 samples per record and the band energy was extracted for each EEG rhythm. The proposed system was compared with naïve Bayes, Bayes Network, k-nearest neighbors (K-NN), multilayer perceptron (MLP), support vector machine (SVM), J48-C4.5 decision tree, and Bagging classification algorithms. The experimental results showed that the RF algorithm outperformed compared to the other approaches and high levels of accuracy (85.39%) for a 6-class classification are obtained. This method exploits high spatial information acquired from the Emotiv EPOC Flex wearable EEG recording device and examines successfully the potential of this device to be used for BCI wheelchair technology.

17 April 2023 in Expert Systems with Applications
Verified
Journal Article
Closed access
Vasileios ChristouVasileios Christou
Vasileios Christou
Ioannis TsoulosIoannis Tsoulos
Ioannis Tsoulos
VLVasileios Loupas
Vasileios Loupas
Alexandros T TzallasAlexandros T Tzallas
Alexandros T Tzallas
Christos GogosChristos Gogos
Christos Gogos
Nikolaos GiannakeasNikolaos Giannakeas
Nikolaos Giannakeas

20 February 2023 in IEEE Access
Verified
Journal Article
Open access
MZMatina C. H. Zerva
Matina C. H. Zerva
Vasileios ChristouVasileios Christou
Vasileios Christou
Nikolaos GiannakeasNikolaos Giannakeas
Nikolaos Giannakeas
Alexandros T TzallasAlexandros T Tzallas
Alexandros T Tzallas
LKLisimachos P. Kondi
Lisimachos P. Kondi
Advanced microscopic techniques such as high-throughput, high-content, multispectral, and 3D imaging could include many images per experiment requiring hundreds of gigabytes (GBs) of memory. Efficient lossy image-compression methods such as joint photographic experts group (JPEG) and JPEG 2000 are crucial to managing these large amounts of data. However, these methods can get visual quality with high compression ratios but do not necessarily maintain the medical data and information integrity. This paper proposes a novel and improved medical image compression method based on color wavelet difference reduction. Specifically, the proposed method is an extension of the standard wavelet difference reduction (WDR) method using mean co-located pixel difference to select the optimum quantity of color images that present the highest similarity in the spatial and temporal domain. The images with large spatiotemporal coherence are encoded as one volume and evaluated regarding the peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM). The proposed method is evaluated in the challenging histopathological microscopy image analysis field using 31 slides of colorectal cancer. It is found that the perceptual quality of the medical image is remarkably high. The results indicate that the PSNR improvement over existing schemes may reach up to 22.65 dB compared to JPEG 2000. Also, it can reach up to 10.33dB compared to a method utilizing discrete wavelet transform (DWT), leading us to implement a mobile and web platform that can be used for compressing and transmitting microscopic medical images in real time.

27 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Vasileios ChristouVasileios Christou
Vasileios Christou
AMAndreas Miltiadous
Andreas Miltiadous
Ioannis TsoulosIoannis Tsoulos
Ioannis Tsoulos
Evangelos C KarvounisEvangelos C Karvounis
Evangelos C Karvounis
Katerina D. TzimourtaKaterina D. Tzimourta
Katerina D. Tzimourta
Nikolaos GiannakeasNikolaos Giannakeas
Nikolaos Giannakeas
Electroencephalography is one of the most commonly used methods for extracting information about the brain’s condition and can be used for diagnosing epilepsy. The EEG signal’s wave shape contains vital information about the brain’s state, which can be challenging to analyse and interpret by a human observer. Moreover, the characteristic waveforms of epilepsy (sharp waves, spikes) can occur randomly through time. Considering all the above reasons, automatic EEG signal extraction and analysis using computers can significantly impact the successful diagnosis of epilepsy. This research explores the impact of different window sizes on EEG signals’ classification accuracy using four machine learning classifiers. The machine learning methods included a neural network with ten hidden nodes trained using three different training algorithms and the k-nearest neighbours classifier. The neural network training methods included the Broyden–Fletcher–Goldfarb–Shanno algorithm, the multistart method for global optimization problems, and a genetic algorithm. The current research utilized the University of Bonn dataset containing EEG data, divided into epochs having 50% overlap and window lengths ranging from 1 to 24 s. Then, statistical and spectral features were extracted and used to train the above four classifiers. The outcome from the above experiments showed that large window sizes with a length of about 21 s could positively impact the classification accuracy between the compared methods.

19 December 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ABAlexandros Bantaloukas-Arjmand
Alexandros Bantaloukas-Arjmand
Constantinos AngelisConstantinos Angelis
Constantinos Angelis
Vasileios ChristouVasileios Christou
Vasileios Christou
Alexandros T TzallasAlexandros T Tzallas
Alexandros T Tzallas
Markos G. TsipourasMarkos G. Tsipouras
Markos G. Tsipouras
Nikolaos GiannakeasNikolaos Giannakeas
Nikolaos Giannakeas
Nonalcoholic fatty liver disease (NAFLD) is responsible for a wide range of pathological disorders. It is characterized by the prevalence of steatosis, which results in excessive accumulation of triglyceride in the liver tissue. At high rates, it can lead to a partial or total occlusion of the organ. In contrast, nonalcoholic steatohepatitis (NASH) is a progressive form of NAFLD, with the inclusion of hepatocellular injury and inflammation histological diseases. Since there is no approved pharmacotherapeutic solution for both conditions, physicians and engineers are constantly in search for fast and accurate diagnostic methods. The proposed work introduces a fully automated classification approach, taking into consideration the high discrimination capability of four histological tissue alterations. The proposed work utilizes a deep supervised learning method, with a convolutional neural network (CNN) architecture achieving a classification accuracy of 95%. The classification capability of the new CNN model is compared with a pre-trained AlexNet model, a visual geometry group (VGG)-16 deep architecture and a conventional multilayer perceptron (MLP) artificial neural network. The results show that the constructed model can achieve better classification accuracy than VGG-16 (94%) and MLP (90.3%), while AlexNet emerges as the most efficient classifier (97%).

9 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KKKyriakos I. Koritsoglou
Kyriakos I. Koritsoglou
Vasileios ChristouVasileios Christou
Vasileios Christou
GNGeorgios Ntritsos
Georgios Ntritsos
Georgios TsoumanisGeorgios Tsoumanis
Georgios Tsoumanis
Markos G. TsipourasMarkos G. Tsipouras
Markos G. Tsipouras
Alexandros T TzallasAlexandros T Tzallas
Alexandros T Tzallas
In this work, a regression method is implemented on a low-cost digital temperature sensor to improve the sensor’s accuracy; thus, following the EN12830 European standard. This standard defines that the maximum acceptable error regarding temperature monitoring devices should not exceed 1 °C for the refrigeration and freezer areas. The purpose of the proposed method is to improve the accuracy of a low-cost digital temperature sensor by correcting its nonlinear response using simple linear regression (SLR). In the experimental part of this study, the proposed method’s outcome (in a custom created dataset containing values taken from a refrigerator) is compared against the values taken from a sensor complying with the EN12830 standard. The experimental results confirmed that the proposed method reduced the mean absolute error (MAE) by 82% for the refrigeration area and 69% for the freezer area—resulting in the accuracy improvement of the low-cost digital temperature sensor. Moreover, it managed to achieve a lower generalization error on the test set when compared to three other machine learning algorithms (SVM, B-ELM, and OS-ELM).