Khairun Nisa Khamil

Mrs. Khairun Nisa Khamil


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2020 in International Journal of Energy Research
Verified
Journal Article
Closed access
PDF file
KKKhairun Nisa Khamil
Khairun Nisa Khamil
MSMohd Faizul Mohd Sabri
Mohd Faizul Mohd Sabri
AYAzdiana Md. Yusop
Azdiana Md. Yusop
FSFatimah Al‐Zahrah Mohd Sa'At
Fatimah Al‐Zahrah Mohd Sa'At
AIAhmad Nizam Isa
Ahmad Nizam Isa

26 June 2020 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
KKKhairun Nisa Khamil
Khairun Nisa Khamil
MSMohd Faizul Mohd Sabri
Mohd Faizul Mohd Sabri
AYAzdiana Md Yusop
Azdiana Md Yusop
In this study, a thermoelectric energy harvesting system (TEHs) that utilized the heat from the surface of asphalt pavement is proposed with the aim to investigate the effects of the heat conduction using different shape structures in the subterranean level. The design model consisted of asphalt base holder to hold the asphalt, top plate for heating, and bottom plate for cooling. The top plate is exposed on the asphalt surface to harvest heat from sunlight, and the bottom plate is submerged into the pavement. The bottom plate is then connected to the cooling element, to take advantage of subterranean cooling to achieve a high-temperature difference between the top and bottom plate of the TEHs. In the past studies, subterranean cooling proved to maintain the underground temperature, but there is no assurance of high-temperature difference. Simulation and experimental investigation were conducted on how the shape structure affects the heat conduction in the subterranean level for two types of cooling elements, which is a cylindrical rod and flat bar. Both simulation and experimental results demonstrate that the cylindrical rod has yielded a higher temperature difference compared to the flat bar. Higher output voltage was generated for the case of the cylindrical rod due to more effective cooling, which resulted in larger temperature differences. Contradicted to previous studies, the field-testing has proved the system with asphalt has indeed influenced the temperature distribution into the system with a 24.39% increase of temperature difference in comparison to the system without the asphalt. Hence, the introduction of subterranean cooling and asphalt pavement heating has proved to improve the performance of TEHs, which makes it possible for utilization as an energy harvester.

9 July 2024 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
AYAzdiana Md Yusop
Azdiana Md Yusop
FTFaiz Bin Mohamad Tarmizi
Faiz Bin Mohamad Tarmizi
NSNoor Asyikin Sulaiman
Noor Asyikin Sulaiman
KKKhairun Nisa Khamil
Khairun Nisa Khamil
RMRamizi Mohammed
Ramizi Mohammed
JSJuwita Mohd Sultan
Juwita Mohd Sultan

19 December 2022 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
MTMohd Khairil Azwan Haji Tugiman
Mohd Khairil Azwan Haji Tugiman
KKKhairun Nisa Khamil
Khairun Nisa Khamil
AYAzdiana Md. Yusop
Azdiana Md. Yusop
MSMohd Faizul Mohd Sabri
Mohd Faizul Mohd Sabri
Renewable energy is the generation of power from natural resources that plays an essential part in our society and economy as it helps reduce emissions for more sustainable future. Therefore, this project aims to analyse two energy harvesting technology, photovoltaic (PV) panels and thermoelectric generators (TEG), in terms of charging and voltage generated from waste heat in a road environment. H-shape heat sinks passive cooling element at subterranean level was implemented to achieve a maximum temperature difference of 15°C for TEG. The top plate, the hot side of TEG, can obtain a maximum of 53°C with a cold side of TEG only increased to 4°C from its initial temperature. Three TEGs connected in series able to charge 5F supercapacitors within 3.5 h, while 3V rated PV solar panel, acquired 15 min to charge the supercapacitor fully. Integrated PV and TEG were evaluated regarding the connection configuration of both energy harvesters into a single system. Series connection of the integrated system takes 29 min to fully charged the supercapacitor where all the results are saved into a microSD card and easily read in Excel. This project provides new insight into the charging performance of the two combinations of energy harvesting technology.

25 March 2025 in Energy Storage
Verified
Journal Article
Closed access
ABAinun Syafiqah Abu Bakar
Ainun Syafiqah Abu Bakar
KKKhairun Nisa Khamil
Khairun Nisa Khamil
AYAzdiana Md Yusop
Azdiana Md Yusop
MRMohd Afzanizam Mohd Rosli
Mohd Afzanizam Mohd Rosli
MSMohd Faizul Mohd Sabri
Mohd Faizul Mohd Sabri

29 August 2024 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
FZFatin Nurul Husna Binti Zainurin
Fatin Nurul Husna Binti Zainurin
KKKhairun Nisa Khamil
Khairun Nisa Khamil
AYAzdiana Md Yusop
Azdiana Md Yusop
MRMohd Afzanizam Bin Mohd Rosli
Mohd Afzanizam Bin Mohd Rosli
SCSiti Amaniah Mohd Chaculi
Siti Amaniah Mohd Chaculi
MSMohd Faizul Mohd Sabri
Mohd Faizul Mohd Sabri