Air conditioning system is a complex system and consumes the most energy in a building. Any fault in the system operation such as cooling tower fan faulty, compressor failure, damper stuck, etc. could lead to energy wastage and reduction in the system’s coefficient of performance (COP). Due to the complexity of the air conditioning system, detecting those faults is hard as it requires exhaustive inspections. This paper consists of two parts; i) to investigate the impact of different faults related to the air conditioning system on COP and ii) to analyse the performances of machine learning algorithms to classify those faults. Three supervised learning classifier models were developed, which were deep learning, support vector machine (SVM) and multi-layer perceptron (MLP). The performances of each classifier were investigated in terms of six different classes of faults. Results showed that different faults give different negative impacts on the COP. Also, the three supervised learning classifier models able to classify all faults for more than 94%, and MLP produced the highest accuracy and precision among all.
1 January 2014 in Modelling and Simulation in Engineering
This study presents the behavioral model of thermal temperature and power generation of a thermoelectric-solar hybrid energy system exposed to dynamic transient sources. In the development of thermoelectric-solar hybrid energy system, studies have focused on the regulation of both systems separately. In practice, a separate control system affects hardware pricing. In this study, an inverse dynamic analysis shaping technique based on exponential function is applied to a solar array (SA) to stabilize output voltage before this technique is combined with a thermoelectric module (TEM). This method can be used to estimate the maximum power point of the hybrid system by initially shaping the input voltage of SA. The behavior of the overall system can be estimated by controlling the behavior of SA, such that SA can follow the output voltage of TEM as the time constant of TEM is greater than that of SA. Moreover, by employing a continuous and differentiable function, the acquired output behavior of the hybrid system can be attained. Data showing the model is obtained from current experiments with predicted values of temperature, internal resistance, and current attributes of TEM. The simulation results show that the proposed input shaper can be used to trigger the output voltage of SA to follow the TEM behavior under transient conditions.
19 December 2022 in International Journal of Ambient Energy
Renewable energy is the generation of power from natural resources that plays an essential part in our society and economy as it helps reduce emissions for more sustainable future. Therefore, this project aims to analyse two energy harvesting technology, photovoltaic (PV) panels and thermoelectric generators (TEG), in terms of charging and voltage generated from waste heat in a road environment. H-shape heat sinks passive cooling element at subterranean level was implemented to achieve a maximum temperature difference of 15°C for TEG. The top plate, the hot side of TEG, can obtain a maximum of 53°C with a cold side of TEG only increased to 4°C from its initial temperature. Three TEGs connected in series able to charge 5F supercapacitors within 3.5 h, while 3V rated PV solar panel, acquired 15 min to charge the supercapacitor fully. Integrated PV and TEG were evaluated regarding the connection configuration of both energy harvesters into a single system. Series connection of the integrated system takes 29 min to fully charged the supercapacitor where all the results are saved into a microSD card and easily read in Excel. This project provides new insight into the charging performance of the two combinations of energy harvesting technology.
17 November 2025 in International Journal of Energy and Water Resources
Access to clean drinking water remains a critical global challenge, particularly in remote areas with limited infrastructure. Solar stills offer a sustainable solution by utilizing solar energy to purify contaminated water through evaporation and condensation. This study investigates the performance enhancement of a triangular solar still by integrating thermoelectric heating and porous agricultural waste (corn husks) to improve evaporation rates. The design features a transparent glass triangular still with a 22° inclined cover, optimized for efficient vapor condensation. Two configurations were tested: a passive system relying solely on solar energy and an active system incorporating thermoelectric modules powered by a 100W solar panel. Results demonstrated that the active system significantly outperformed the passive one, producing 110 mL of distilled water over five hours compared to 68 mL, marking a 42 mL increase. The active system achieved a 3.7% evaporation efficiency, while the passive system reached 3.02%, confirming the thermoelectric module's contribution to heating and productivity. Additionally, corn husks enhanced water absorption and evaporation due to their porous structure. Water quality analysis confirmed a pH within the WHO-recommended range (6.5–8.5), ensuring safety for consumption. This study highlights the potential of thermoelectric-integrated solar stills combined with agricultural waste to improve freshwater production, offering an eco-friendly and cost-effective solution for water-scarce regions. Further optimization could enhance efficiency, making it a viable alternative to conventional desalination methods.
LTE which stands for Long Term Evolution is one of wireless broadband technology which provides an increased on both network capacity and speed to user. As LTE network grows, LTE mobile data services becomes demanding mode of communication. From audio call to video conference, video conference to online bank transaction, user lives conveniently with LTE. The speed of LTE network is up to 300 Mbps with the coverage of 100 km. However, LTE network could not be standalone on this chain for so long as it might occur generalization of services where the quality cannot be guarantee. Here Quality of Service (QoS) play it roles in managing and design wireless services that suit every single user necessity. QoS refers to the ability of a network to accomplish maximum bandwidth and handle with another element within network performance. Not to mention, minor support that made this possible is by studying on how EPC could make a different in improving the QoS in LTE network. Evolved Packet Core (EPC) is designed to support smooth transfer for voice and data to a base station. Hence, investigation in benefit of EPC toward QoS in LTE is carry out and simulation result obtained will be evaluated throughout this paper.