Stefano Lucchini

Dr. Stefano Lucchini

IRCSS Istituto Ortopedico Rizzoli
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2021 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
SLStefano Lucchini
Stefano Lucchini
FCFrancesco Castagnini
Francesco Castagnini
FGFederico Giardina
Federico Giardina
FTFrancesco Tentoni
Francesco Tentoni
CMClaudio Masetti
Claudio Masetti
FTFrancesco Traina
Francesco Traina

27 January 2022 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
FCFrancesco Castagnini
Francesco Castagnini
BBBarbara Bordini
Barbara Bordini
MCMonica Cosentino
Monica Cosentino
CACristina Ancarani
Cristina Ancarani
SLStefano Lucchini
Stefano Lucchini
FTFrancesco Traina
Francesco Traina

15 July 2022 in Journal of Orthopaedics and Traumatology
Verified
Journal Article
Open access
PDF file
FCFrancesco Castagnini
Francesco Castagnini
SLStefano Lucchini
Stefano Lucchini
BBBarbara Bordini
Barbara Bordini
MCMonica Cosentino
Monica Cosentino
FPFrancesco Pardo
Francesco Pardo
Francesco TrainaFrancesco Traina
Francesco Traina
Background: Stem choice in total hip arthroplasty (THA) for hip dysplasia is still controversial. The aims of the study were to evaluate (1) which stem design provided the highest percentage of adequate reconstructions in THA for dysplasia and (2) any correlation between the reconstructions provided by the stems and the native femoral morphology. Materials and methods: 150 CT scans including 200 adult dysplastic hips were randomly selected. Using the 3D CT-based software Hip-Op for surgical planning, the native hip anatomy was studied. Then, a single wedge tapered stem, an anatomical stem and a conical tapered stem were simulated in every hip. An adequate reconstruction of hip biomechanics was obtained when combined anteversion, offset restoration, coronal and sagittal tilt, canal filling and leg lengthening were inside the normal ranges. Results: Conical stems achieved the highest percentage of adequate reconstructions (87%, p < 0.0001). The anatomical stem was the worst performer. Single wedge and anatomical stem acceptability was mainly influenced by the combined anteversion. Stem anteversion was correlated with the femoral anteversion (fair correlation), the calcar femorale (fair) and the mediolateral femoral diameter at isthmus (poor). When the femoral anteversion was ≥ 25°, combined anteversion was very acceptable for the conical stem (99.2%), whereas the rate of acceptable combined anteversion for the single wedge tapered stem was 71.4%, and that for the anatomical stem was 51.6% (p < 0.0001). Conclusions: Stem choice in developmental hip dysplasia is mainly driven by appropriate combined anteversion, which is dependent on the coronal and axial femoral morphologies. As a rule of thumb, tapered stems are adequate when femoral anteversion is < 25°; conical stems should be adopted for higher anteversions. Level of evidence: IV.

3 June 2022 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
SLStefano Lucchini
Stefano Lucchini
MBMassimiliano Baleani
Massimiliano Baleani
FGFederico Giardina
Federico Giardina
AMAndrea Martelli
Andrea Martelli
FCFrancesco Castagnini
Francesco Castagnini
FTFrancesco Traina
Francesco Traina
Background: Ceramic bearings are used in total hip arthroplasty due to their excellent wear behaviour and biocompatibility. The major concern related to their use is material brittleness, which significantly impacts on the risk of fracture of ceramic components. Fracture toughness improvement has contributed to the decrease in fracture rate, at least of the prosthetic head. However, the root cause behind these rare events is not fully understood. This study evaluated head fracture occurrence in a sizeable cohort of patients with fourth-generation ceramic-on-ceramic implants and described the circumstances reported by patients in the rare cases of head fracture. Methods: The clinical survivorship of 29,495 hip prostheses, with fourth-generation ceramic bearings, was determined using data from a joint replacement registry. The average follow-up period was 5.2 years (range 0.1–15.6). Retrieval analysis was performed in one case for which the ceramic components were available. Results: Clinical outcomes confirmed the extremely low fracture rate of fourth-generation ceramic heads: only two out of 29,495 heads fractured. The two fractures, both involving 36 mm heads, occurred without a concurrent or previous remarkable trauma. Considering the feature of the fractured head, a multi-stage crack growth mechanism has been hypothesized to occur following damage at the head–neck taper interface. Conclusions: Surgeons must continue to pay attention to the assembly of the femoral head: achieving a proper head seating on a clean taper is a prerequisite to decrease the risk of occurrence of any damage process within head–neck junction, which may cause high stress concentration at the contact surface, promoting crack nucleation and propagation even in toughened ceramics.

3 December 2021 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
ETEnrico Tassinari
Enrico Tassinari
FMFederica Mariotti
Federica Mariotti
FCFrancesco Castagnini
Francesco Castagnini
SLStefano Lucchini
Stefano Lucchini
FPFrancesco Perdisa
Francesco Perdisa
FTFrancesco Traina
Francesco Traina
Purpose: The aim is to compare the results of isolated hip arthroscopy in patients with borderline dysplasia with Lateral center edge angle (LCEA) between 18° and 25° with a control group of patients with normal LCEA (> 25°).Methods: Fifty hip arthroscopies performed in 45 patients were retrospectively evaluated. Exclusion criteria were: age > 40, hip arthritis > grade 2 according to Tonnis classification, femoral head avascular necrosis, pediatric’s orthopaedics conditions and true dysplasia with LCEA < 18°.Two groups were identified: group A with 15 hips with LCEA between 25° and 18° and Group control B made of 35 hips with LCEA > 25°.Results: The groups were homogeneous for demography and pre‐operative WOMAC and HOOS. Osteoplasty for CAM were performed in 100% of patients in both groups, only in 12 hips (34.4%) in group B we had both femoral and acetabular osteoplasty. Labral repair was performed in 86% of patients in group A, in 60% of patients in group B, capsular plication in 93% of group A, in 5% of case of group B. WOMAC and HOOS statically significant improved in both groups at final follow‐up (24 months). No cases in both groups required conversion to total hip arthroplasty.Clinical outcomes of study group were comparable to the control group.Conclusion: Even if the present small series is not conclusive, we suggest isolated arthroscopic management of patients with FAI and LCEA between 18° and 25°, but capsular plication and careful labral management are strongly recommended.Level of evidence: Level IV.

21 January 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FCFrancesco Castagnini
Francesco Castagnini
FPFrancesco Pardo
Francesco Pardo
SLStefano Lucchini
Stefano Lucchini
MRMarco Rotini
Marco Rotini
BCBruno Cavalieri
Bruno Cavalieri
Francesco TrainaFrancesco Traina
Francesco Traina
Cementless primary stems in revision hip arthroplasties may be conservative options to preserve bone stock and provide adequate reconstruction of the hip biomechanics. However, there is still little evidence about indications, limitations, and outcomes. This narrative review showed that conventional standard stems were adopted in different revision settings, up to Paprosky IIIA grade bone defects. In cases of acceptable metaphyseal bone stock, when a scratch fit of at least 4 cm can be achieved, a conventional cementless stem may be an adequate solution. Mid-term clinical and radiographic outcomes and survival rates were similar to long revision stems, whereas complications, surgical time, and costs were lower among conventional stems. However, unsuitable contexts for conventional stems included canal diameters larger than 18 mm and failed revision stems with cortical weakening. Even short stems can be considered in revisions, in order to preserve bone stock and stay proximal to femoral remodeling zones and bone/cement plugs. Short stems were successfully adopted up to Paprosky IIIA bone defects, achieving mid-term survival rates not inferior to long revision stems. Ageing, osteoporosis, and intraoperative femoral fractures were the main negative prognostic factors. In very select cases, a downsizing technique (from longer to shorter stems) may be adopted to simplify the procedure and reduce complications.