Anna Axelin

Prof. Anna Axelin

Department of Nursing Science, University of Turku, Finland
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2012 in Acta Paediatrica
Verified
Journal Article
Open access
PDF file
RFRenée Flacking
Renée Flacking
LLLiisa Lehtonen
Liisa Lehtonen
GTGill Thomson
Gill Thomson
AAAnna Axelin
Anna Axelin
SASari Ahlqvist
Sari Ahlqvist
TGthe SCENE group
the SCENE group
In this paper, we highlight the need for acknowledging the importance and impact of both physical and emotional closeness between the preterm infant and parent in the neonatal intensive care unit. Physical closeness refers to being spatially close and emotional closeness to parental feelings of being emotionally connected to the infant (experiencing feelings of love, warmth and affection). Through consideration of the literature in this area, we outline some of the reasons why physical closeness and emotional closeness are crucial to the physical, emotional and social well‐being of both the infant and the parent. These include positive effects on infant brain development, parent psychological well‐being and on the parent–infant relationship. The influence of the neonatal unit environment and culture on physical and emotional closeness is also discussed.Conclusions:  Culturally sensitive care practices, procedures and the physical environment need to be considered to facilitate parent–infant closeness, such as through early and prolonged skin‐to‐skin contact, family‐centred care, increased visiting hours, family rooms and optimization of the space on the units. Further research is required to explore factors that facilitate both physical and emotional closeness to ensure that parent–infant closeness is a priority within neonatal care.

1 November 2014 in International Journal of Nursing Studies
Verified
Journal Article
Closed access
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
AAAnna Axelin
Anna Axelin
SSSanna Salanterä
Sanna Salanterä
HMHanna-Leena Melender
Hanna-Leena Melender

18 January 2022 in Journal of Medical Internet Research
Verified
Journal Article
Open access
RCRui Cao
Rui Cao
IAIman Azimi
Iman Azimi
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
HNHannakaisa Niela-Vilen
Hannakaisa Niela-Vilen
AAAnna Axelin
Anna Axelin
ARAmir Rahmani
Amir Rahmani
Background: Photoplethysmography is a noninvasive and low-cost method to remotely and continuously track vital signs. The Oura Ring is a compact photoplethysmography-based smart ring, which has recently drawn attention to remote health monitoring and wellness applications. The ring is used to acquire nocturnal heart rate (HR) and HR variability (HRV) parameters ubiquitously. However, these parameters are highly susceptible to motion artifacts and environmental noise. Therefore, a validity assessment of the parameters is required in everyday settings. Objective: This study aims to evaluate the accuracy of HR and time domain and frequency domain HRV parameters collected by the Oura Ring against a medical grade chest electrocardiogram monitor. Methods: We conducted overnight home-based monitoring using an Oura Ring and a Shimmer3 electrocardiogram device. The nocturnal HR and HRV parameters of 35 healthy individuals were collected and assessed. We evaluated the parameters within 2 tests, that is, values collected from 5-minute recordings (ie, short-term HRV analysis) and the average values per night sleep. A linear regression method, the Pearson correlation coefficient, and the Bland–Altman plot were used to compare the measurements of the 2 devices. Results: Our findings showed low mean biases of the HR and HRV parameters collected by the Oura Ring in both the 5-minute and average-per-night tests. In the 5-minute test, the error variances of the parameters were different. The parameters provided by the Oura Ring dashboard (ie, HR and root mean square of successive differences [RMSSD]) showed relatively low error variance compared with the HRV parameters extracted from the normal interbeat interval signals. The Pearson correlation coefficient tests (P<.001) indicated that HR, RMSSD, average of normal heart beat intervals (AVNN), and percentage of successive normal beat-to-beat intervals that differ by more than 50 ms (pNN50) had high positive correlations with the baseline values; SD of normal beat-to-beat intervals (SDNN) and high frequency (HF) had moderate positive correlations, and low frequency (LF) and LF:HF ratio had low positive correlations. The HR, RMSSD, AVNN, and pNN50 had narrow 95% CIs; however, SDNN, LF, HF, and LF:HF ratio had relatively wider 95% CIs. In contrast, the average-per-night test showed that the HR, RMSSD, SDNN, AVNN, pNN50, LF, and HF had high positive relationships (P<.001), and the LF:HF ratio had a moderate positive relationship (P<.001). The average-per-night test also indicated considerably lower error variances than the 5-minute test for the parameters. Conclusions: The Oura Ring could accurately measure nocturnal HR and RMSSD in both the 5-minute and average-per-night tests. It provided acceptable nocturnal AVNN, pNN50, HF, and SDNN accuracy in the average-per-night test but not in the 5-minute test. In contrast, the LF and LF:HF ratio of the ring had high error rates in both tests.

2 November 2020 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
MMMilad Asgari Mehrabadi
Milad Asgari Mehrabadi
IAIman Azimi
Iman Azimi
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
AAAnna Axelin
Anna Axelin
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
ARAmir Rahmani
Amir Rahmani
Background: Assessment of sleep quality is essential to address poor sleep quality and understand changes. Owing to the advances in the Internet of Things and wearable technologies, sleep monitoring under free-living conditions has become feasible and practicable. Smart rings and smartwatches can be employed to perform mid- or long-term home-based sleep monitoring. However, the validity of such wearables should be investigated in terms of sleep parameters. Sleep validation studies are mostly limited to short-term laboratory tests; there is a need for a study to assess the sleep attributes of wearables in everyday settings, where users engage in their daily routines. Objective: This study aims to evaluate the sleep parameters of the Oura ring along with the Samsung Gear Sport watch in comparison with a medically approved actigraphy device in a midterm everyday setting, where users engage in their daily routines. Methods: We conducted home-based sleep monitoring in which the sleep parameters of 45 healthy individuals (23 women and 22 men) were tracked for 7 days. Total sleep time (TST), sleep efficiency (SE), and wake after sleep onset (WASO) of the ring and watch were assessed using paired t tests, Bland-Altman plots, and Pearson correlation. The parameters were also investigated considering the gender of the participants as a dependent variable. Results: We found significant correlations between the ring’s and actigraphy’s TST (r=0.86; P<.001), WASO (r=0.41; P<.001), and SE (r=0.47; P<.001). Comparing the watch with actigraphy showed a significant correlation in TST (r=0.59; P<.001). The mean differences in TST, WASO, and SE of the ring and actigraphy were within satisfactory ranges, although there were significant differences between the parameters (P<.001); TST and SE mean differences were also within satisfactory ranges for the watch, and the WASO was slightly higher than the range (31.27, SD 35.15). However, the mean differences of the parameters between the watch and actigraphy were considerably higher than those of the ring. The watch also showed a significant difference in TST (P<.001) between female and male groups. Conclusions: In a sample population of healthy adults, the sleep parameters of both the Oura ring and Samsung watch have acceptable mean differences and indicate significant correlations with actigraphy, but the ring outperforms the watch in terms of the nonstaging sleep parameters.

1 April 2006 in Early Human Development
Verified
Journal Article
Closed access
AAAnna Axelin
Anna Axelin
SSSanna Salanterä
Sanna Salanterä
LLLiisa Lehtonen
Liisa Lehtonen

31 March 2017 in Acta Paediatrica
Verified
Journal Article
Open access
PDF file
SRSimo Raiskila
Simo Raiskila
AAAnna Axelin
Anna Axelin
LTLiis Toome
Liis Toome
SCSylvia Caballero
Sylvia Caballero
BTBente Silnes Tandberg
Bente Silnes Tandberg
LLLiisa Lehtonen
Liisa Lehtonen
Aim: Little is known about the amount of physical parent–infant closeness in neonatal intensive care units (NICUs), and this study explored that issue in six European countries.Methods: The parents of 328 preterm infants were recruited in 11 NICUs in Finland, Estonia, Sweden, Norway, Italy and Spain. They filled in daily diaries about how much time they spent in the NICU, in skin‐to‐skin contact (SSC) and holding their babies in the first two weeks of their hospitalisation.Results: The parents' NICU presence varied from a median of 3.3 (minimum 0.7–maximum 6.7) to 22.3 (18.7–24.0) hours per day (p < 0.001), SSC varied from 0.3 (0–1.4) to 6.6 (2.2–19.5) hours per day (p < 0.001) and holding varied from 0 (0–1.5) to 3.2 (0–7.4) hours per day (p < 0.001). Longer SSC was associated with singleton babies and more highly educated mothers. Holding the baby for longer was associated with gestational age. The most important factor supporting parent–infant closeness was the opportunity to stay overnight in the NICU. Having other children and the distance from home to the hospital had no impact on parent–infant closeness.Conclusion: Parents spent more time in NICUs if they could stay overnight, underlining the importance that these facilities play in establishing parent–infant closeness.