Fatemeh Sarhaddi

Dr. Fatemeh Sarhaddi

Department of Computing, University of Turku, Finland
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2022 in Journal of Medical Internet Research
Verified
Journal Article
Open access
RCRui Cao
Rui Cao
IAIman Azimi
Iman Azimi
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
HNHannakaisa Niela-Vilen
Hannakaisa Niela-Vilen
AAAnna Axelin
Anna Axelin
ARAmir Rahmani
Amir Rahmani
Background: Photoplethysmography is a noninvasive and low-cost method to remotely and continuously track vital signs. The Oura Ring is a compact photoplethysmography-based smart ring, which has recently drawn attention to remote health monitoring and wellness applications. The ring is used to acquire nocturnal heart rate (HR) and HR variability (HRV) parameters ubiquitously. However, these parameters are highly susceptible to motion artifacts and environmental noise. Therefore, a validity assessment of the parameters is required in everyday settings. Objective: This study aims to evaluate the accuracy of HR and time domain and frequency domain HRV parameters collected by the Oura Ring against a medical grade chest electrocardiogram monitor. Methods: We conducted overnight home-based monitoring using an Oura Ring and a Shimmer3 electrocardiogram device. The nocturnal HR and HRV parameters of 35 healthy individuals were collected and assessed. We evaluated the parameters within 2 tests, that is, values collected from 5-minute recordings (ie, short-term HRV analysis) and the average values per night sleep. A linear regression method, the Pearson correlation coefficient, and the Bland–Altman plot were used to compare the measurements of the 2 devices. Results: Our findings showed low mean biases of the HR and HRV parameters collected by the Oura Ring in both the 5-minute and average-per-night tests. In the 5-minute test, the error variances of the parameters were different. The parameters provided by the Oura Ring dashboard (ie, HR and root mean square of successive differences [RMSSD]) showed relatively low error variance compared with the HRV parameters extracted from the normal interbeat interval signals. The Pearson correlation coefficient tests (P<.001) indicated that HR, RMSSD, average of normal heart beat intervals (AVNN), and percentage of successive normal beat-to-beat intervals that differ by more than 50 ms (pNN50) had high positive correlations with the baseline values; SD of normal beat-to-beat intervals (SDNN) and high frequency (HF) had moderate positive correlations, and low frequency (LF) and LF:HF ratio had low positive correlations. The HR, RMSSD, AVNN, and pNN50 had narrow 95% CIs; however, SDNN, LF, HF, and LF:HF ratio had relatively wider 95% CIs. In contrast, the average-per-night test showed that the HR, RMSSD, SDNN, AVNN, pNN50, LF, and HF had high positive relationships (P<.001), and the LF:HF ratio had a moderate positive relationship (P<.001). The average-per-night test also indicated considerably lower error variances than the 5-minute test for the parameters. Conclusions: The Oura Ring could accurately measure nocturnal HR and RMSSD in both the 5-minute and average-per-night tests. It provided acceptable nocturnal AVNN, pNN50, HF, and SDNN accuracy in the average-per-night test but not in the 5-minute test. In contrast, the LF and LF:HF ratio of the ring had high error rates in both tests.

2 November 2020 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
MMMilad Asgari Mehrabadi
Milad Asgari Mehrabadi
IAIman Azimi
Iman Azimi
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
AAAnna Axelin
Anna Axelin
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
ARAmir Rahmani
Amir Rahmani
Background: Assessment of sleep quality is essential to address poor sleep quality and understand changes. Owing to the advances in the Internet of Things and wearable technologies, sleep monitoring under free-living conditions has become feasible and practicable. Smart rings and smartwatches can be employed to perform mid- or long-term home-based sleep monitoring. However, the validity of such wearables should be investigated in terms of sleep parameters. Sleep validation studies are mostly limited to short-term laboratory tests; there is a need for a study to assess the sleep attributes of wearables in everyday settings, where users engage in their daily routines. Objective: This study aims to evaluate the sleep parameters of the Oura ring along with the Samsung Gear Sport watch in comparison with a medically approved actigraphy device in a midterm everyday setting, where users engage in their daily routines. Methods: We conducted home-based sleep monitoring in which the sleep parameters of 45 healthy individuals (23 women and 22 men) were tracked for 7 days. Total sleep time (TST), sleep efficiency (SE), and wake after sleep onset (WASO) of the ring and watch were assessed using paired t tests, Bland-Altman plots, and Pearson correlation. The parameters were also investigated considering the gender of the participants as a dependent variable. Results: We found significant correlations between the ring’s and actigraphy’s TST (r=0.86; P<.001), WASO (r=0.41; P<.001), and SE (r=0.47; P<.001). Comparing the watch with actigraphy showed a significant correlation in TST (r=0.59; P<.001). The mean differences in TST, WASO, and SE of the ring and actigraphy were within satisfactory ranges, although there were significant differences between the parameters (P<.001); TST and SE mean differences were also within satisfactory ranges for the watch, and the WASO was slightly higher than the range (31.27, SD 35.15). However, the mean differences of the parameters between the watch and actigraphy were considerably higher than those of the ring. The watch also showed a significant difference in TST (P<.001) between female and male groups. Conclusions: In a sample population of healthy adults, the sleep parameters of both the Oura ring and Samsung watch have acceptable mean differences and indicate significant correlations with actigraphy, but the ring outperforms the watch in terms of the nonstaging sleep parameters.

8 December 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
KKKianoosh Kazemi
Kianoosh Kazemi
IAIman Azimi
Iman Azimi
RCRui Cao
Rui Cao
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
ARAmir M. Rahmani
Amir M. Rahmani
Background: Photoplethysmography (PPG) is a low-cost and easy-to-implement method to measure vital signs, including heart rate (HR) and pulse rate variability (PRV) which widely used as a substitute of heart rate variability (HRV). The method is used in various wearable devices. For example, Samsung smartwatches are PPG-based open-source wristbands used in remote well-being monitoring and fitness applications. However, PPG is highly susceptible to motion artifacts and environmental noise. A validation study is required to investigate the accuracy of PPG-based wearable devices in free-living conditions. Objective: We evaluate the accuracy of PPG signals—collected by the Samsung Gear Sport smartwatch in free-living conditions—in terms of HR and time-domain and frequency-domain HRV parameters against a medical-grade chest electrocardiogram (ECG) monitor. Methods: We conducted 24-hours monitoring using a Samsung Gear Sport smartwatch and a Shimmer3 ECG device. The monitoring included 28 participants (14 male and 14 female), where they engaged in their daily routines. We evaluated HR and HRV parameters during the sleep and awake time. The parameters extracted from the smartwatch were compared against the ECG reference. For the comparison, we employed the Pearson correlation coefficient, Bland-Altman plot, and linear regression methods. Results: We found a significantly high positive correlation between the smartwatch’s and Shimmer ECG’s HR, time-domain HRV, LF, and HF and a significant moderate positive correlation between the smartwatch’s and shimmer ECG’s LF/HF during sleep time. The mean biases of HR, time-domain HRV, and LF/HF were low, while the biases of LF and HF were moderate during sleep. The regression analysis showed low error variances of HR, AVNN, and pNN50, moderate error variances of SDNN, RMSSD, LF, and HF, and high error variances of LF/HF during sleep. During the awake time, there was a significantly high positive correlation of AVNN and a moderate positive correlation of HR, while the other parameters indicated significantly low positive correlations. RMSSD and SDNN showed low mean biases, and the other parameters had moderate mean biases. In addition, AVNN had moderate error variance while the other parameters indicated high error variances. Conclusion: The Samsung smartwatch provides acceptable HR, time-domain HRV, LF, and HF parameters during sleep time. In contrast, during the awake time, AVNN and HR show satisfactory accuracy, and the other HRV parameters have high errors.

24 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
IAIman Azimi
Iman Azimi
SLSina Labbaf
Sina Labbaf
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
NDNikil Dutt
Nikil Dutt
ARAmir Rahmani
Amir Rahmani
Pregnancy is a unique time when many mothers gain awareness of their lifestyle and its impacts on the fetus. High-quality care during pregnancy is needed to identify possible complications early and ensure the mother’s and her unborn baby’s health and well-being. Different studies have thus far proposed maternal health monitoring systems. However, they are designed for a specific health problem or are limited to questionnaires and short-term data collection methods. Moreover, the requirements and challenges have not been evaluated in long-term studies. Maternal health necessitates a comprehensive framework enabling continuous monitoring of pregnant women. In this paper, we present an Internet-of-Things (IoT)-based system to provide ubiquitous maternal health monitoring during pregnancy and postpartum. The system consists of various data collectors to track the mother’s condition, including stress, sleep, and physical activity. We carried out the full system implementation and conducted a real human subject study on pregnant women in Southwestern Finland. We then evaluated the system’s feasibility, energy efficiency, and data reliability. Our results show that the implemented system is feasible in terms of system usage during nine months. We also indicate the smartwatch, used in our study, has acceptable energy efficiency in long-term monitoring and is able to collect reliable photoplethysmography data. Finally, we discuss the integration of the presented system with the current healthcare system.

3 June 2022 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
IAIman Azimi
Iman Azimi
AAAnna Axelin
Anna Axelin
HNHannakaisa Niela-Vilen
Hannakaisa Niela-Vilen
PLPasi Liljeberg
Pasi Liljeberg
ARAmir Rahmani
Amir Rahmani
Background: Heart rate variability (HRV) is a noninvasive method that reflects the regulation of the autonomic nervous system. Altered HRV is associated with adverse mental or physical health complications. The autonomic nervous system also has a central role in physiological adaption during pregnancy, causing normal changes in HRV. Objective: The aim of this study was to assess trends in heart rate (HR) and HRV parameters as a noninvasive method for remote maternal health monitoring during pregnancy and 3-month postpartum period. Methods: A total of 58 pregnant women were monitored using an Internet of Things–based remote monitoring system during pregnancy and 3-month postpartum period. Pregnant women were asked to continuously wear Gear Sport smartwatch to monitor their HR and HRV extracted from photoplethysmogram (PPG) signals. In addition, a cross-platform mobile app was used to collect background and delivery-related information. We analyzed PPG signals collected during the night and discarded unreliable signals by applying a PPG quality assessment method to the collected signals. HR, HRV, and normalized HRV parameters were extracted from reliable signals. The normalization removed the effect of HR changes on HRV trends. Finally, we used hierarchical linear mixed models to analyze the trends of HR, HRV, and normalized HRV parameters. Results: HR increased significantly during the second trimester (P<.001) and decreased significantly during the third trimester (P=.006). Time-domain HRV parameters, average normal interbeat intervals (IBIs; average normal IBIs [AVNN]), SD of normal IBIs (SDNN), root mean square of the successive difference of normal IBIs (RMSSD), normalized SDNN, and normalized RMSSD decreased significantly during the second trimester (P<.001). Then, AVNN, SDNN, RMSSD, and normalized SDNN increased significantly during the third trimester (with P=.002, P<.001, P<.001, and P<.001, respectively). Some of the frequency-domain parameters, low-frequency power (LF), high-frequency power (HF), and normalized HF, decreased significantly during the second trimester (with P<.001, P<.001, and P=.003, respectively), and HF increased significantly during the third trimester (P=.007). In the postpartum period, normalized RMSSD decreased (P=.01), and the LF to HF ratio (LF/HF) increased significantly (P=.004). Conclusions: Our study indicates the physiological changes during pregnancy and the postpartum period. We showed that HR increased and HRV parameters decreased as pregnancy proceeded, and the values returned to normal after delivery. Moreover, our results show that HR started to decrease, whereas time-domain HRV parameters and HF started to increase during the third trimester. The results also indicated that age was significantly associated with HRV parameters during pregnancy and postpartum period, whereas education level was associated with HRV parameters during the third trimester. In addition, our results demonstrate the possibility of continuous HRV monitoring in everyday life settings.

3 February 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HNHannakaisa Niela-Vilén
Hannakaisa Niela-Vilén
JAJennifer Auxier
Jennifer Auxier
EEEeva Ekholm
Eeva Ekholm
Fatemeh SarhaddiFatemeh Sarhaddi
Fatemeh Sarhaddi
MMMilad Asgari Mehrabadi
Milad Asgari Mehrabadi
AAAnna Axelin
Anna Axelin
Background: Technology enables the continuous monitoring of personal health parameter data during pregnancy regardless of the disruption of normal daily life patterns. Our research group has established a project investigating the usefulness of an Internet of Things–based system and smartwatch technology for monitoring women during pregnancy to explore variations in stress, physical activity and sleep. The aim of this study was to examine daily patterns of well-being in pregnant women before and during the national stay-at-home restrictions related to the COVID-19 pandemic in Finland. Methods: A longitudinal cohort study design was used to monitor pregnant women in their everyday settings. Two cohorts of pregnant women were recruited. In the first wave in January-December 2019, pregnant women with histories of preterm births (gestational weeks 22–36) or late miscarriages (gestational weeks 12–21); and in the second wave between October 2019 and March 2020, pregnant women with histories of full-term births (gestational weeks 37–42) and no pregnancy losses were recruited. The final sample size for this study was 38 pregnant women. The participants continuously used the Samsung Gear Sport smartwatch and their heart rate variability, and physical activity and sleep data were collected. Subjective stress, activity and sleep reports were collected using a smartphone application developed for this study. Data between February 12 to April 8, 2020 were included to cover four-week periods before and during the national stay-at-home restrictions. Hierarchical linear mixed models were exploited to analyze the trends in the outcome variables. Results: The pandemic-related restrictions were associated with changes in heart rate variability: the standard deviation of all normal inter-beat intervals (p = 0.034), low-frequency power (p = 0.040) and the low-frequency/high-frequency ratio (p = 0.013) increased compared with the weeks before the restrictions. Women’s subjectively evaluated stress levels also increased significantly. Physical activity decreased when the restrictions were set and as pregnancy proceeded. The total sleep time also decreased as pregnancy proceeded, but pandemic-related restrictions were not associated with sleep. Daily rhythms changed in that the participants overall started to sleep later and woke up later. Conclusions: The findings showed that Finnish pregnant women coped well with the pandemic-related restrictions and lockdown environment in terms of stress, physical activity and sleep.