Christian Gossens

Christian Gossens


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2018 in Movement Disorders
Verified
Journal Article
Open access
PDF file
FLFlorian Lipsmeier
Florian Lipsmeier
KTKirsten I. Taylor
Kirsten I. Taylor
TKTimothy Kilchenmann
Timothy Kilchenmann
DWDetlef Wolf
Detlef Wolf
ASAlf Scotland
Alf Scotland
MLMichael Lindemann
Michael Lindemann
Background: Ubiquitous digital technologies such as smartphone sensors promise to fundamentally change biomedical research and treatment monitoring in neurological diseases such as PD, creating a new domain of digital biomarkers.Objectives: The present study assessed the feasibility, reliability, and validity of smartphone‐based digital biomarkers of PD in a clinical trial setting.Methods: During a 6‐month, phase 1b clinical trial with 44 Parkinson participants, and an independent, 45‐day study in 35 age‐matched healthy controls, participants completed six daily motor active tests (sustained phonation, rest tremor, postural tremor, finger‐tapping, balance, and gait), then carried the smartphone during the day (passive monitoring), enabling assessment of, for example, time spent walking and sit‐to‐stand transitions by gyroscopic and accelerometer data.Results: Adherence was acceptable: Patients completed active testing on average 3.5 of 7 times/week. Sensor‐based features showed moderate‐to‐excellent test‐retest reliability (average intraclass correlation coefficient = 0.84). All active and passive features significantly differentiated PD from controls with P < 0.005. All active test features except sustained phonation were significantly related to corresponding International Parkinson and Movement Disorder Society–Sponsored UPRDS clinical severity ratings. On passive monitoring, time spent walking had a significant (P = 0.005) relationship with average postural instability and gait disturbance scores. Of note, for all smartphone active and passive features except postural tremor, the monitoring procedure detected abnormalities even in those Parkinson participants scored as having no signs in the corresponding International Parkinson and Movement Disorder Society–Sponsored UPRDS items at the site visit.Conclusions: These findings demonstrate the feasibility of smartphone‐based digital biomarkers and indicate that smartphone‐sensor technologies provide reliable, valid, clinically meaningful, and highly sensitive phenotypic data in Parkinson's disease. © 2018 The Authors. Movement Disorders published by Wiley Periodicals, Inc. on behalf of International Parkinson and Movement Disorder Society.

23 March 2005 in Organometallics
Verified
Journal Article
Closed access
ADAntoine Dorcier
Antoine Dorcier
PDPaul Dyson
Paul Dyson
CGChristian Gossens
Christian Gossens
URUrsula Rothlisberger
Ursula Rothlisberger
RSRosario Scopelliti
Rosario Scopelliti
ITIvano Tavernelli
Ivano Tavernelli

31 December 2005 in Organometallics
Verified
Journal Article
Closed access
CSClaudine Scolaro
Claudine Scolaro
TGTilmann J. Geldbach
Tilmann J. Geldbach
SRSebastien Rochat
Sebastien Rochat
ADAntoine Dorcier
Antoine Dorcier
CGChristian Gossens
Christian Gossens
PDPaul Dyson
Paul Dyson

30 August 2019 in Journal of Medical Internet Research
Verified
Journal Article
Open access
LMLuciana Midaglia
Luciana Midaglia
PMPatricia Mulero
Patricia Mulero
XMXavier Montalban
Xavier Montalban
JGJennifer Graves
Jennifer Graves
SHStephen L Hauser
Stephen L Hauser
MLMichael Lindemann
Michael Lindemann
Background: Current clinical assessments of people with multiple sclerosis are episodic and may miss critical features of functional fluctuations between visits. Objective: The goal of the research was to assess the feasibility of remote active testing and passive monitoring using smartphones and smartwatch technology in people with multiple sclerosis with respect to adherence and satisfaction with the FLOODLIGHT test battery. Methods: People with multiple sclerosis (aged 20 to 57 years; Expanded Disability Status Scale 0-5.5; n=76) and healthy controls (n=25) performed the FLOODLIGHT test battery, comprising active tests (daily, weekly, every two weeks, or on demand) and passive monitoring (sensor-based gait and mobility) for 24 weeks using a smartphone and smartwatch. The primary analysis assessed adherence (proportion of weeks with at least 3 days of completed testing and 4 hours per day passive monitoring) and questionnaire-based satisfaction. In-clinic assessments (clinical and magnetic resonance imaging) were performed. Results: People with multiple sclerosis showed 70% (16.68/24 weeks) adherence to active tests and 79% (18.89/24 weeks) to passive monitoring; satisfaction score was on average 73.7 out of 100. Neither adherence nor satisfaction was associated with specific population characteristics. Test-battery assessments had an at least acceptable impact on daily activities in over 80% (61/72) of people with multiple sclerosis. Conclusions: People with multiple sclerosis were engaged and satisfied with the FLOODLIGHT test battery. FLOODLIGHT sensor-based measures may enable continuous assessment of multiple sclerosis disease in clinical trials and real-world settings. Trial Registration: ClinicalTrials.gov: NCT02952911; https://clinicaltrials.gov/ct2/show/NCT02952911

14 July 2021 in Multiple Sclerosis Journal
Verified
Journal Article
Open access
XMXavier Montalban
Xavier Montalban
JGJennifer Graves
Jennifer Graves
LMLuciana Midaglia
Luciana Midaglia
PMPatricia Mulero
Patricia Mulero
LJLaura Julian
Laura Julian
SHStephen L Hauser
Stephen L Hauser
Background: Sensor-based monitoring tools fill a critical gap in multiple sclerosis (MS) research and clinical care. Objective: The aim of this study is to assess performance characteristics of the Floodlight Proof-of-Concept (PoC) app. Methods: In a 24-week study (clinicaltrials.gov: NCT02952911), smartphone-based active tests and passive monitoring assessed cognition (electronic Symbol Digit Modalities Test), upper extremity function (Pinching Test, Draw a Shape Test), and gait and balance (Static Balance Test, U-Turn Test, Walk Test, Passive Monitoring). Intraclass correlation coefficients (ICCs) and age- or sex-adjusted Spearman’s rank correlation determined test–retest reliability and correlations with clinical and magnetic resonance imaging (MRI) outcome measures, respectively. Results: Seventy-six people with MS (PwMS) and 25 healthy controls were enrolled. In PwMS, ICCs were moderate-to-good (ICC(2,1) = 0.61–0.85) across tests. Correlations with domain-specific standard clinical disability measures were significant for all tests in the cognitive ( r = 0.82, p < 0.001), upper extremity function (|r|= 0.40–0.64, all p < 0.001), and gait and balance domains ( r = −0.25 to −0.52, all p < 0.05; except for Static Balance Test: r = −0.20, p > 0.05). Most tests also correlated with Expanded Disability Status Scale, 29-item Multiple Sclerosis Impact Scale items or subscales, and/or normalized brain volume. Conclusion: The Floodlight PoC app captures reliable and clinically relevant measures of functional impairment in MS, supporting its potential use in clinical research and practice.

24 July 2008 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
CGChristian Gossens
Christian Gossens
ITIvano Tavernelli
Ivano Tavernelli
URUrsula Rothlisberger
Ursula Rothlisberger