Background: Current clinical assessments of people with multiple sclerosis are episodic and may miss critical features of functional fluctuations between visits. Objective: The goal of the research was to assess the feasibility of remote active testing and passive monitoring using smartphones and smartwatch technology in people with multiple sclerosis with respect to adherence and satisfaction with the FLOODLIGHT test battery. Methods: People with multiple sclerosis (aged 20 to 57 years; Expanded Disability Status Scale 0-5.5; n=76) and healthy controls (n=25) performed the FLOODLIGHT test battery, comprising active tests (daily, weekly, every two weeks, or on demand) and passive monitoring (sensor-based gait and mobility) for 24 weeks using a smartphone and smartwatch. The primary analysis assessed adherence (proportion of weeks with at least 3 days of completed testing and 4 hours per day passive monitoring) and questionnaire-based satisfaction. In-clinic assessments (clinical and magnetic resonance imaging) were performed. Results: People with multiple sclerosis showed 70% (16.68/24 weeks) adherence to active tests and 79% (18.89/24 weeks) to passive monitoring; satisfaction score was on average 73.7 out of 100. Neither adherence nor satisfaction was associated with specific population characteristics. Test-battery assessments had an at least acceptable impact on daily activities in over 80% (61/72) of people with multiple sclerosis. Conclusions: People with multiple sclerosis were engaged and satisfied with the FLOODLIGHT test battery. FLOODLIGHT sensor-based measures may enable continuous assessment of multiple sclerosis disease in clinical trials and real-world settings. Trial Registration: ClinicalTrials.gov: NCT02952911; https://clinicaltrials.gov/ct2/show/NCT02952911
28 May 2020 in IEEE Journal of Biomedical and Health Informatics
Leveraging consumer technology such as smartphone and smartwatch devices to objectively assess people with multiple sclerosis (PwMS) remotely could capture unique aspects of disease progression. This study explores the feasibility of assessing PwMS and Healthy Control's (HC) physical function by characterising gait-related features, which can be modelled using machine learning (ML) techniques to correctly distinguish subgroups of PwMS from healthy controls. A total of 97 subjects (24 HC subjects, 52 mildly disabled (PwMSmild, EDSS [0-3]) and 21 moderately disabled (PwMSmod, EDSS [3.5-5.5]) contributed data which was recorded from a Two-Minute Walk Test (2MWT) performed out-of-clinic and daily over a 24-week period. Signal-based features relating to movement were extracted from sensors in smartphone and smartwatch devices. A large number of features (n=156) showed fair-to-strong (R>0.3) correlations with clinical outcomes. LASSO feature selection was applied to select and rank subsets of features used for dichotomous classification between subject groups, which were compared using Logistic Regression (LR), Support Vector Machines (SVM) and Random Forest (RF) models. Classifications of subject types were compared using data obtained from smartphone, smartwatch and the fusion of features from both devices. Models built on smartphone features alone achieved the highest classification performance, indicating that accurate and remote measurement of the ambulatory characteristics of HC and PwMS can be achieved with only one device. It was observed however that smartphone-based performance is affected by inconsistent placement location (running belt versus pocket). Results show that PwMSmod can be distinguished from HC subjects (Acc. 82.2 ± 2.9%, Sen. 80.1 ± 3.9%, Spec. 87.2 ± 4.2%, F $^1$ 84.3 ± 3.8), and PwMSmild (Acc. 82.3 ± 1.9%, Sen. 71.6 ± 4.2%, Spec. 87.0 ± 3.2%, F $_1$ 75.1 ± 2.2) using an SVM classifier with a Radial Basis Function (RBF). PwMSmild were shown to exhibit HC-like behaviour and were thus less distinguishable from HC (Acc. 66.4 ± 4.5%, Sen. 67.5 ± 5.7%, Spec. 60.3 ± 6.7%, F $_1$ 58.6 ± 5.8). Finally, it was observed that subjects in this study demonstrated low intra- and high inter-subject variability which was representative of subject specific gait characteristics.
20 April 2020 in IEEE Transactions on Biomedical Engineering
Parkinson's disease (PD) is a neurodegenerative disorder that affects multiple neurological systems. Traditional PD assessment is conducted by a physician during infrequent clinic visits. Using smartphones, remote patient monitoring has the potential to obtain objective behavioral data semi-continuously, track disease fluctuations, and avoid rater dependency. Smartphones collect sensor data during various active tests and passive monitoring, including balance (postural instability), dexterity (skill in performing tasks using hands), gait (the pattern of walking), tremor (involuntary muscle contraction and relaxation), and voice. Some of the features extracted from smartphone data are potentially associated with specific PD symptoms identified by physicians. To leverage large-scale cross-modality smartphone features, we propose a machine-learning framework for performing automated disease assessment. The framework consists of a two-step feature selection procedure and a generic model based on the elastic-net regularization. Using this framework, we map the PD-specific architecture of behaviors using data obtained from both PD participants and healthy controls (HCs). Utilizing these atlases of features, the framework shows promises to (a) discriminate PD participants from HCs, and (b) estimate the disease severity of individuals with PD. Data analysis results from 437 behavioral features obtained from 72 subjects (37 PD and 35 HC) sampled from 17 separate days during a period of up to six months suggest that this framework is potentially useful for the analysis of remotely collected smartphone sensor data in individuals with PD.
The measurement of gait characteristics during a self-administered 2-minute walk test (2MWT), in persons with multiple sclerosis (PwMS), using a single body-worn device, has the potential to provide high-density longitudinal information on disease progression, beyond what is currently measured in the clinician-administered 2MWT. The purpose of this study is to determine the test-retest reliability, standard error of measurement (SEM) and minimum detectable change (MDC) of features calculated on gait characteristics, harvested during a self-administered 2MWT in a home environment, in 51 PwMS and 11 healthy control (HC) subjects over 24 weeks, using a single waist-worn inertial sensor-based smartphone. Excellent, or good to excellent test-retest reliability were observed in 58 of the 92 temporal, spatial and spatiotemporal gait features in PwMS. However, these were less reliable for HCs. Low SEM% and MDC% values were observed for most of the distribution measures for all gait characteristics for PwMS and HCs. This study demonstrates the inter-session test-retest reliability and provides an indication of clinically important change estimates, for interpreting the outcomes of gait characteristics measured using a body-worn smartphone, during a self-administered 2MWT. This system thus provides a reliable measure of gait characteristics in PwMS, supporting its application for the longitudinal assessment of gait deficits in this population.
28 June 2022 in Journal of Medical Internet Research
Background: Remote monitoring of Huntington disease (HD) signs and symptoms using digital technologies may enhance early clinical diagnosis and tracking of disease progression, guide treatment decisions, and monitor response to disease-modifying agents. Several recent studies in neurodegenerative diseases have demonstrated the feasibility of digital symptom monitoring. Objective: The aim of this study was to evaluate a novel smartwatch- and smartphone-based digital monitoring platform to remotely monitor signs and symptoms of HD. Methods: This analysis aimed to determine the feasibility and reliability of the Roche HD Digital Monitoring Platform over a 4-week period and cross-sectional validity over a 2-week interval. Key criteria assessed were feasibility, evaluated by adherence and quality control failure rates; test-retest reliability; known-groups validity; and convergent validity of sensor-based measures with existing clinical measures. Data from 3 studies were used: the predrug screening phase of an open-label extension study evaluating tominersen (NCT03342053) and 2 untreated cohorts—the HD Natural History Study (NCT03664804) and the Digital-HD study. Across these studies, controls (n=20) and individuals with premanifest (n=20) or manifest (n=179) HD completed 6 motor and 2 cognitive tests at home and in the clinic. Results: Participants in the open-label extension study, the HD Natural History Study, and the Digital-HD study completed 89.95% (1164/1294), 72.01% (2025/2812), and 68.98% (1454/2108) of the active tests, respectively. All sensor-based features showed good to excellent test-retest reliability (intraclass correlation coefficient 0.89-0.98) and generally low quality control failure rates. Good overall convergent validity of sensor-derived features to Unified HD Rating Scale outcomes and good overall known-groups validity among controls, premanifest, and manifest participants were observed. Among participants with manifest HD, the digital cognitive tests demonstrated the strongest correlations with analogous in-clinic tests (Pearson correlation coefficient 0.79-0.90). Conclusions: These results show the potential of the HD Digital Monitoring Platform to provide reliable, valid, continuous remote monitoring of HD symptoms, facilitating the evaluation of novel treatments and enhanced clinical monitoring and care for individuals with HD.
Objective: Smartphone devices may enable out-of-clinic assessments in chronic neurological diseases. We describe the Draw a Shape (DaS) Test, a smartphone-based and remotely administered test of Upper Extremity (UE) function developed for people with multiple sclerosis (PwMS). This work introduces DaS-related features that characterise UE function and impairment, and aims to demonstrate how multivariate modelling of these metrics can reliably predict the 9-Hole Peg Test (9HPT), a clinician-administered UE assessment in PwMS.Approach: The DaS Test instructed PwMS and healthy controls (HC) to trace predefined shapes on a smartphone screen. A total of 93 subjects (HC,n= 22; PwMS,n= 71) contributed both dominant and non-dominant handed DaS tests. PwMS subjects were characterised as those with normal (nPwMS,n= 50) and abnormal UE function (aPwMS,n= 21) with respect to their average 9HPT time (≤ or > 22.7 (s), respectively).L1-regularization techniques, combined with linear least squares (OLS, IRLS), or non-linear support vector (SVR) or random forest (RFR) regression were investigated as functions to map relevant DaS features to 9HPT times.Main results: It was observed that average non-dominant handed 9HPT times were more accurately predicted by DaS features (r2= 0.41, 0.05; MAE: 2.08 ± 0.34 (s)) than average dominant handed 9HPTs (r2= 0.39, 0.05; MAE: 2.32 ± 0.43 (s)), using simple linear IRLS ( 0.01). Moreover, it was found that the Mean absolute error (MAE) in predicted 9HPTs was comparable to the variability of actual 9HPT times within HC, nPwMS and aPwMS groups respectively. The 9HPT however exhibited large heteroscedasticity resulting in less stable predictions of longer 9HPT times.Significance: This study demonstrates the potential of the smartphone-based DaS Test to reliably predict 9HPT times and remotely monitor UE function in PwMS.