Siyu Zhou

Dr. Siyu Zhou

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Photonics Research
Verified
Journal Article
Closed access
SZSiyu Zhou
Siyu Zhou
VLVunam Le
Vunam Le
SXShilin Xiong
Shilin Xiong
YYYuetang Yang
Yuetang Yang
KNKai Ni
Kai Ni
Guanhao WuGuanhao Wu
Guanhao Wu
Precise and fast determination of position and orientation, which is normally achieved by distance and angle measurements, has broad applications in academia and industry. We propose a dynamic three-degree-of-freedom measurement technique based on dual-comb interferometry and a self-designed grating-corner-cube (GCC) combined sensor. Benefiting from its unique combination of diffraction and reflection characteristics, the absolute distance, pitch, and yaw of the GCC sensor can be determined simultaneously by resolving the phase spectra of the corresponding diffracted beams. We experimentally demonstrate that the method exhibits a ranging precision (Allan deviation) of 13.7 nm and an angular precision of 0.088 arcsec, alongside a 1 ms reaction time. The proposed technique is capable of precise and fast measurement of distances and two-dimensional angles over long stand-off distances. A system with such an overall performance may be potentially applied to space missions, including in tight formation-flying satellites, for spacecraft rendezvous and docking, and for antenna measurement as well as the precise manufacture of components including lithography machines and aircraft-manufacturing devices.

26 July 2019 in Optics Express
Verified
Journal Article
Closed access
SZSiyu Zhou
Siyu Zhou
SXShilin Xiong
Shilin Xiong
ZZZebin Zhu
Zebin Zhu
Guanhao WuGuanhao Wu
Guanhao Wu
A simplified phase-stable dual-comb interferometer for absolute distance measurement within a short dynamic range is proposed in this paper. The experimental results demonstrate that stable phase-difference information and lower timing jitter can be obtained within a time delay of 2000 ns between the reference interference signal and measurement interference signal. Using the proposed technique, the time-of-flight (TOF) result can link directly to the carrier-wave interferometric (CWI) result in an average time of 20 ms and can reach 2 nm precision in 0.5 s averaging time. Millimeter-scale measurement dynamic range and nanometer-level precision can thus be achieved without additional noise suppression. This method can also be applied at different stand-off distances.

29 January 2020 in Optics Express
Verified
Journal Article
Closed access
SZSiyu Zhou
Siyu Zhou
CLChen Lin
Chen Lin
YYYuetang Yang
Yuetang Yang
Guanhao WuGuanhao Wu
Guanhao Wu
A multi-pulse sampling dual-comb ranging (MS-DCR) method is proposed in this paper. Four sampling pulses and two signal pulses separated in the time domain are generated in a repetition period by fiber delay. Through multi-pulse linear optical sampling, eight cross-correlation interferograms (IGMs) are generated in an updating period. The proposed method realizes the multiplication of IGMs so that additional ranging results can be obtained. The experimental results demonstrate that we suppress any random noise by averaging the ranging results and improve the precision of the time-of-flight (TOF) method and carrier-wave interferometric (CWI) method simultaneously. The precision of TOF is improved from 3.85 µm to 1.39 µm without time averaging and that of CWI is improved from 25 nm to 11 nm. The TOF result can link to the interferometric phase with 15 ms averaging, and a precision of 0.48 nm is reached with 0.5 s averaging. The proposed technique overcomes the limitations of linear optical sampling in conventional dual-comb interferometers and achieves faster and higher precision distance measurements without decreasing the unambiguity range.

29 September 2021 in Optics Express
Verified
Journal Article
Closed access
RJRuilin Jiang
Ruilin Jiang
SZSiyu Zhou
Siyu Zhou
Guanhao WuGuanhao Wu
Guanhao Wu
A dual-comb ranging (DCR) system without spectral aliasing based on free-running fiber lasers was proposed. By monitoring the repetition frequency over time, we compensate for the instability of the optical pulse train from the free-running fiber lasers. We demonstrated a double-channel filtering structure that eliminates the aliasing between multiheterodyne beats in radio frequency interferograms. Without any frequency locking, the DCR system implements stable running for at least 60 min. The system realizes a 6-µm repetition precision without averaging and shows good consistency with a commercial interferometer.

22 February 2022 in Optics Express
Verified
Journal Article
Closed access
RZRuixue Zhang
Ruixue Zhang
LSLiheng Shi
Liheng Shi
SZSiyu Zhou
Siyu Zhou
JZJinxu Zhang
Jinxu Zhang
BLBin Liu
Bin Liu
Guanhao WuGuanhao Wu
Guanhao Wu
Spectroscopic ellipsometry is a powerful tool for characterizing thin film, polarization optics, semiconductors, and others. Conventional approaches are subject to restrictions of mechanical instability and measurement speed. The complex locking scheme of previous dual-comb spectroscopic ellipsometry belies its practicability. We present and demonstrate here dynamic spectroscopic ellipsometry based on a simplified phase-stable dual-comb system, which could realize the online dynamic measurement of optical properties of materials. A precision of 1.31 nm and a combined uncertainty of 13.80 nm (k = 2) in the thickness measurement of thin-film samples has been achieved. Moreover, the dynamic performance of the system is investigated under a high data acquisition rate (1 kHz) with a dynamic resolution of ellipsometric parameter better than 0.1 rad.

27 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SZSiyu Zhou
Siyu Zhou
VLVunam Le
Vunam Le
QMQinggai Mi
Qinggai Mi
Guanhao WuGuanhao Wu
Guanhao Wu
This paper presents a specifically designed grating-corner-cube sensor for precise roll angle measurements. Owing to the diffraction characteristics of the transmission grating and reflection characteristics of the corner cube, two spatially separated parallel beams are naturally constructed. Through differential detection of the positions of two parallel beams, we experimentally demonstrate the possibility of a precise roll angle measurement at a high refresh rate. A performance evaluation of the proposed technique indicates a stability of 0.46 arcsec over 5 min. Compared with a commercial autocollimator over a range of 500 arcsec, the residuals are maintained within ±2 arcsec with a standard deviation of 1.37 arcsec. Furthermore, a resolution of 0.8 arcsec can be achieved using the proposed method. The developed compact roll angle sensor has potential applications in academic and industrial fields.