Zebin Zhu

Zebin Zhu

Auto-generated profile, based on publicly available information

Zebin Zhu

State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing 100084, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Engineering
Verified
Journal Article
Open access
ZZZebin Zhu
Zebin Zhu
Guanhao WuGuanhao Wu
Guanhao Wu

26 February 2018 in Optics Express
Verified
Journal Article
Closed access
ZZZebin Zhu
Zebin Zhu
GXGuangyao Xu
Guangyao Xu
KNKai Ni
Kai Ni
QZQian Zhou
Qian Zhou
Guanhao WuGuanhao Wu
Guanhao Wu
We present an absolute distance measurement system using a phase-stable dual-comb system with 56.09 MHz repetition rate and 2 kHz repetition rate difference. A relative phase stability of 0.1 rad in 0.5 ms between two combs is achieved using a mutual locking scheme. The dual-comb ranging system combines the time-of-flight (TOF) method, synthetic-wavelength interferometry (SWI), and carrier wave interferometry (CWI). Each method provides a particular ambiguity range and resolution, and they can be applied simultaneously and linked to enhance the precision and measurement rate of the ranging system. The experimental results demonstrate that a precision of 1.2 μm is obtained without time averaging, and the precision can be improved to 3 nm with only 10 ms averaging time using the SWI method described in this study. The precision reaches a sub-nanometer when the averaging time exceeds 0.1 s. A system with high accuracy and short averaging time would enhance fast measurement performance in various industrial applications. The ambiguity range is about 2.67 m in our system, we test the performance of the system with 1.5 mm range at 1.5 m distance.

15 June 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
ZZZebin Zhu
Zebin Zhu
KNKai Ni
Kai Ni
QZQian Zhou
Qian Zhou
Guanhao WuGuanhao Wu
Guanhao Wu
A phase-stable dual-comb interferometer measures materials’ broadband optical response functions, including amplitude, frequency, and phase, making it a powerful tool for optical metrology. Normally, the phase-stable dual-comb interferometer is realized via tight phase-locking methods. This paper presents a post-correction algorithm that can compensate for carrier wave phase noise and interferogram timing jitter. The compensating signal is a beat between two combs using a free-running continuous wave laser as an optical intermediary. In our experiment, sub-hertz relative linewidth, ~1 ns relative timing jitter, and 0.2 rad precision in the carrier phase is demonstrated.

26 July 2019 in Optics Express
Verified
Journal Article
Closed access
SZSiyu Zhou
Siyu Zhou
SXShilin Xiong
Shilin Xiong
ZZZebin Zhu
Zebin Zhu
Guanhao WuGuanhao Wu
Guanhao Wu
A simplified phase-stable dual-comb interferometer for absolute distance measurement within a short dynamic range is proposed in this paper. The experimental results demonstrate that stable phase-difference information and lower timing jitter can be obtained within a time delay of 2000 ns between the reference interference signal and measurement interference signal. Using the proposed technique, the time-of-flight (TOF) result can link directly to the carrier-wave interferometric (CWI) result in an average time of 20 ms and can reach 2 nm precision in 0.5 s averaging time. Millimeter-scale measurement dynamic range and nanometer-level precision can thus be achieved without additional noise suppression. This method can also be applied at different stand-off distances.

12 March 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Guanhao WuGuanhao Wu
Guanhao Wu
LLLei Liao
Lei Liao
SXShilin Xiong
Shilin Xiong
GLGuoyuan Li
Guoyuan Li
ZCZhijian Cai
Zhijian Cai
ZZZebin Zhu
Zebin Zhu
We present a synthetic-wavelength based heterodyne interferometer of optical frequency combs with wide consecutive measurement range for absolute distance measurement. The synthetic wavelength is derived from two wavelengths obtained by two band-pass filters. The interferometric phase of the synthetic wavelength is used as a marker for the pulse-to-pulse alignment, which greatly improves the accuracy of traditional peak finding method. The consecutive measurement range is enlarged by using long fiber to increase the path length difference of the reference and measurement arms. The length of the long fiber is stabilized according to the interferometric phase of a CW laser. The experimental results show the present system can realize an accuracy of 75 nm in 350 mm consecutive measurement range.

7 November 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
RZRuixue Zhang
Ruixue Zhang
ZZZebin Zhu
Zebin Zhu
Guanhao WuGuanhao Wu
Guanhao Wu
We propose a method to precisely characterize the optical response of a fiber Bragg grating (FBG) sensor for static strain sensing by using dual–comb spectroscopy (DCS). By digitally post–correcting the mutual noise between the two combs, a robust and pure strain sensing system is achieved by compensating for the temperature–induced frequency shift of the FBG sensor. The comb–resolved radio–frequency (RF) spectra generated by DCS are obtained. Meanwhile, the stability of the central Bragg frequency of the FBG–reflected spectrum in the RF domain is 0.315 kHz, which is better than the difference of repetition rate (1 kHz). A reference FBG is used for detecting and compensating for the temperature–induced central frequency drift. Finally, a spectral sensitivity of 0.85 pm/µɛ with 0.8 µɛ static strain resolution is achieved.