Aloys Akumu

Dr. Aloys Akumu

IEEE Member
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
GIG. K. Irungu
G. K. Irungu
Aloys AkumuAloys Akumu
Aloys Akumu
Josiah Lange MundaJosiah Lange Munda
Josiah Lange Munda
Various techniques of fault diagnostics in oil-filled electrical equipment have been used in many years and are well documented in literature. The common techniques include; IEEE key gas, IEC 60599 gas ratios, Rodgers ratios, Doernenburg ratios and the Duval triangle. Among all the available techniques, Duval triangle remains the most accurate to date. This paper presents a new fault diagnostic method which combines fuzzy trapezoidal membership functions derived empirically after analyzing faults documented in literature and the evidential reasoning techniques. Like in Duval triangle, three gases; methane, acetylene and ethylene are used. First these gases are normalized against their sum. The normalized values are transformed into fuzzy trapezoidal membership functions whose outcome are synthesized into a particular fault type by the evidential reasoning technique. One hundred and seventeen fault cases visually inspected by experts and documented in IEC TC 10 databases are used for verification. This new technique is easy to understand, uses simple standard mathematical expressions and can easily identify simultaneous faults. Unlike Duval triangle where two or more faults lying at the same spot are not easily recognizable, the new technique identifies faults based on numerical values hence it does not have this drawback.

3 February 2019 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
EMEdwell Tafara Mharakurwa
Edwell Tafara Mharakurwa
GNG. N. Nyakoe
G. N. Nyakoe
Aloys AkumuAloys Akumu
Aloys Akumu
Decision making on transformer insulation condition based on the evaluated incipient faults and aging stresses has been the norm for many asset managers. Despite being the extensively applied methodology in power transformer incipient fault detection, solely dissolved gas analysis (DGA) techniques cannot quantify the detected fault severity. Fault severity is the core property in transformer maintenance rankings. This paper presents a fuzzy logic methodology in determining transformer faults and severity through use of energy of fault formation of the evolved gasses during transformer faulting event. Additionally, the energy of fault formation is a temperature-dependent factor for all the associated evolved gases. Instead of using the energy-weighted DGA, the calculated total energy of related incipient fault is used for severity determination. Severity of faults detected by fuzzy logic-based key gas method is evaluated through the use of collected data from several in-service and faulty transformers. DGA results of oil samples drawn from transformers of different specifications and age are used to validate the model. Model results show that correctly detecting fault type and its severity determination based on total energy released during faults can enhance decision-making in prioritizing maintenance of faulty transformers.

5 August 2016 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
GIG. K. Irungu
G. K. Irungu
Aloys AkumuAloys Akumu
Aloys Akumu
Josiah Lange MundaJosiah Lange Munda
Josiah Lange Munda
Transformer life and age is taken to be that of its insulation system. In order to facilitate decision making on transformer optimization in maintenance, loading, relocation and replacement, the insulation system condition must be monitored and evaluated based on faults and aging stress levels. Various techniques can be applied to this effect. This paper presents the application of two such techniques: fuzzy logic and evidential reasoning. Over twenty case studies are evaluated using real field data with the same inputs given to the two models. The data is looked at from different transformer perspectives like dissolved gases, insulation physical, chemical and electrical properties but finally categorized into fault stresses and aging stresses. These transformer stresses are analyzed from various measurable variables that characterizes them. Logical transformer management decisions can be taken based on the stress level assessment outcome. Trapezoidal, generalized bell-shaped and Gaussian membership functions were applied to assess their effect on the fuzzy logic outcome. The results show evidential reasoning to be better in terms of flexibility and ability to handle measurement uncertainty whereas fuzzy logic is advantageous with a large volume of expert database.

1 August 2019
Verified
Conference Paper
Closed access
KMKatleho Moloi
Katleho Moloi
Aloys AkumuAloys Akumu
Aloys Akumu
Fault detection, classification and estimation in power systems is one of the most critical aspects of the engineering society. This goes beyond engineering factors to economic implications. Thus, proper applications of protection schemes are required to minimize the equipment damage resulting from a fault. This paper presents a method which tries to proactively detect, classify and estimate the position of the fault. A simplified two bus 132 kV system is modelled to study the effect of the proposed fault diagnostic method. The proposed method has a fault feature extraction technique done by stationary wavelet transform (SWT) on the fault signal. Relevance Vector Machine (RVM) and Support vector machine (SVM) schemes are applied for fault classification and detection. Fault location along the distribution line is achieved by using Support Vector Regression (SVR). The proposed method comprises of SWT-RVM and SVR schemes and tested using MATLAB.

25 June 2003
Verified
Conference Paper
Closed access
Aloys AkumuAloys Akumu
Aloys Akumu
FAF. Adachi
F. Adachi
NKN. Kawaguchi
N. Kawaguchi
ROR. Ozaki
R. Ozaki
HIH. Ihori
H. Ihori
KAK. Arii
K. Arii
In this paper, the authors present a three-dimensional numerical simulation of partial discharge (PD) acoustic wave propagation that has been developed to provide time-domain signal representation in a model transformer. The numerical modeling of acoustic PD data is used to support interpretations of laboratory experimental data and to enhance the understanding of acoustic wave propagation in a structure like the power transformer, and hence PD source location in the same. It is intended that an extension of the work presented here, to account for real transformer geometry and also to visualize the propagation of acoustic wave fronts, will later be compared with field results. The three-dimensional wave equation, given by c/sup 2//spl nabla//sup 2/P=/spl part//sup 2/P//spl part/t/sup 2/, where c is the acoustic velocity and P the pressure wave field, defines an initial value problem and describes time evolution. The goal of the numerical code is to track that time evolution with some desired accuracy taking into consideration the boundary conditions that govern the evolution in time of points on the boundary of the spatial region of interest. This is particularly important for the satisfactory modeling of a complex structure like power transformer. In solving the above equation using the finite-difference method, of particular interest are the conditions of numerical stability. In this paper, the authors apply the stability analysis method originally developed by Von Neumann. The simulation results are in agreement with the results obtained from the laboratory experiments.

15 June 2003 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
Aloys AkumuAloys Akumu
Aloys Akumu
HMHajime Masai
Hajime Masai
FAFutoshi Adachi
Futoshi Adachi
RORyotaro Ozaki
Ryotaro Ozaki
HIHaruo Ihori
Haruo Ihori
KAKiyomitsu Arii
Kiyomitsu Arii