Edwell Tafara Mharakurwa

Dr. Edwell Tafara Mharakurwa

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2019 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
EMEdwell Tafara Mharakurwa
Edwell Tafara Mharakurwa
GNG. N. Nyakoe
G. N. Nyakoe
Aloys AkumuAloys Akumu
Aloys Akumu
Decision making on transformer insulation condition based on the evaluated incipient faults and aging stresses has been the norm for many asset managers. Despite being the extensively applied methodology in power transformer incipient fault detection, solely dissolved gas analysis (DGA) techniques cannot quantify the detected fault severity. Fault severity is the core property in transformer maintenance rankings. This paper presents a fuzzy logic methodology in determining transformer faults and severity through use of energy of fault formation of the evolved gasses during transformer faulting event. Additionally, the energy of fault formation is a temperature-dependent factor for all the associated evolved gases. Instead of using the energy-weighted DGA, the calculated total energy of related incipient fault is used for severity determination. Severity of faults detected by fuzzy logic-based key gas method is evaluated through the use of collected data from several in-service and faulty transformers. DGA results of oil samples drawn from transformers of different specifications and age are used to validate the model. Model results show that correctly detecting fault type and its severity determination based on total energy released during faults can enhance decision-making in prioritizing maintenance of faulty transformers.

13 December 2019 in Advances in Fuzzy Systems
Verified
Journal Article
Open access
EMEdwell Tafara Mharakurwa
Edwell Tafara Mharakurwa
RGRutendo Goboza
Rutendo Goboza
The health index scheme can be the most fundamental tool that unifies all transformer condition status information into a singular outcome, thereby enhancing the power transformer asset management and life longevity strategies. This study aims at establishing a multiple parameter-dependent transformer health index estimation model cascaded with a fuzzy logic inference system. This strategy is centered on the effect of dynamic loading regime, varying hotspot temperatures and multiple attesting results of the insulation system. Furthermore, a nonintrusive degree of polymerization (DP) model based on furans and carbon oxide ratios as DP pointers is also factored in developing the health index model. The general outcome of the health index depends on entirely considered elements, but not on any isolated attribute. Data obtained from in-service transformers were used to validate the proposed model. The outcome of the model mirrors the practical condition of the evaluated transformers. Therefore, the proposed health index model can be a vital tool to asset managers and power utilities.

26 October 2022 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
PDF file
EMEdwell Tafara Mharakurwa
Edwell Tafara Mharakurwa
Power transformers are essential assets in power system networks that must be meticulously monitored throughout their operational life cycle. Given that a substantial percentage of in-service power transformers around the world have reached the end of their projected technical lifespan, utilities are adopting various transformer condition-based maintenance strategies to minimize potentially devastating equipment failure. Thus, further usage of aging fleet of power system assets can be improved by gaining a better understanding of life threatening factors. In-service power transformers and their auxiliary components are susceptible to a variety of operational risks, which can compromise their performance and efficiency, thus resulting in devastating failures, financial losses, and power outages. Hence, it is necessary to investigate transformer life time issues so as to fully grasp the operational and performance status in order to reduce failures and operating costs. This paper presents a unified framework of attributes pertaining to life time issues for transformer operation evaluation together with a summary of recent findings in order to explore the current status and progress of this rapidly progressing field. The failure statistics analysis is presented first, followed by an examination of the transformer’s insulation degradation and aging mechanism. Furthermore, emphasis was on detailing the commonly adopted models and strategies in transformer condition evaluation, fault diagnostics, and remnant life estimation. Despite significant advancements in ascertaining transformer health diagnosis and prognosis technologies, including test accuracy, quick, precise fault localization, and fault type classification, there are still several shortcomings that require additional research, and thus future research perspectives are also discussed.

10 September 2024 in International Journal on Interactive Design and Manufacturing (IJIDeM)
Verified
Journal Article
Open access
PDF file
SOSteven Otieno Otieno
Steven Otieno Otieno
FMFredrick Madaraka Mwema
Fredrick Madaraka Mwema
EMEdwell Tafara Mharakurwa
Edwell Tafara Mharakurwa
Tien-Chien JenTien-Chien Jen
Tien-Chien Jen
Studying the interactions among major plastic injection molding process parameters is necessary to understand how they collectively influence major defects such as warpage hence enabling optimization of the process for improved product quality. Existing process parameter interaction studies have used statistical approximations, which have limitations such as reduced predictive power and limited accuracy. To overcome these limitations, this study presents an alternative method of analysis of the interactions among process parameters based on fuzzy logic intelligent algorithm. Through computer aided engineering, factorial design of experiment and fuzzy logic modelling, the study evaluated the effects of major injection molding process parameter interactions on warpage. The results obtained indicated a general increase in warpage with increase in parameters such as melt temperature, mold temperature, injection pressure and cool time whereas an increase in parameters such as ambient temperature and packing pressure decreased warpage. Parameter interactions were obtained both statistically and based on fuzzy logic model and their significance tested through ANOVA. Ambient temperature (30.6%) and melt temperatures (18.7%) had the greatest effect on warpage all with P-values of 0.000 whereas cooling time (0.1%) had the least effect with P-value of 0.250. The largest two way interaction affecting warpage involved melt temperature and cooling time with a contribution of 12.2% whereas the largest three way interaction involves ambient temperature, packing pressure and injection pressure with a contribution of 2.7%. Also, despite cooling time having the least mains effect, most interaction terms with greater effect on warpage involved cooling time and melt temperature. The results from this study provides an insight on targeted injection molding process parameter control for defect minimization.

8 March 2023 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Closed access
PDF file
PRPeter Kipkemoi Rono
Peter Kipkemoi Rono
JBJean Bosco Byiringiro
Jean Bosco Byiringiro
EMEdwell Tafara Mharakurwa
Edwell Tafara Mharakurwa
ACAndrew Chesang
Andrew Chesang

1 January 2025 in Journal of Electrical and Computer Engineering
Verified
Journal Article
Open access
SMStephen W. Mathenge
Stephen W. Mathenge
EMEdwell Tafara Mharakurwa
Edwell Tafara Mharakurwa
LMLucas Mogaka
Lucas Mogaka
Radial distribution networks (RDNs) often experience high power losses, voltage instability, and operational inefficiencies because of their low‐voltage, high‐current characteristics, and fluctuating load behavior. This study investigates the optimization of capacitor placement and sizing using the Crow Search Algorithm (CSA) to enhance voltage stability, minimize power losses, and reduce operational costs. Power flow analysis was conducted via the Backward/Forward Sweep (BFS) method on the IEEE 33‐bus system, incorporating four load models: Constant impedance (CZ), constant current (CI), constant power (CP), and composite ZIP. The optimization objective was to minimize the total operating annual cost (TOAC), which includes active power loss costs and annual capacitor installation costs. CSA’s performance was benchmarked against invasive weed optimization (IWO), teacher learner‐based optimization (TLBO), and artificial bee colony (ABC) algorithms. Simulation results demonstrated that CSA improved the voltage stability index (VSI) from 0.61 to 0.68 (CP), 0.69 (CI), 0.65 (CZ), and 0.66 (ZIP), and reduced active power losses by 30.41%, 26.01%, 36.45%, and 33.78% for CP, CI, CZ, and ZIP loads, respectively. Corresponding cost savings achieved using CSA were 30.28% (CP), 25.85% (CI), 36.35% (CZ), and 33.67% (ZIP), confirming superior performance over the compared methods. The highest TOAC was observed for CZ loads ($303,570.2), while the lowest was for CI loads ($195,386.4), reflecting the economic influence of load model variation. To ensure practical applicability and robustness, a sensitivity analysis of optimization algorithms under varying load models was performed. This included evaluating the impact of varying capacitor sizing ranges, system sizes, load compositions, and algorithm initialization conditions. Results confirmed that CSA maintained stability and effectiveness under diverse scenarios, validating its reliability and adaptability in real‐world RDN planning. Overall, the proposed CSA‐based approach provided a robust and cost‐effective solution for optimizing capacitor placement and sizing in RDNs, supporting both technical performance and economic sustainability.