Jasmina Primožič

Prof. Dr. Jasmina Primožič

Department of orthodontics and jaw orthopaedics, Medical Faculty, University of Ljubljana, Slovenia
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2021 in Antioxidants
Verified
Journal Article
Open access
PDF file
JPJasmina Primožič
Jasmina Primožič
BPBorut Poljšak
Borut Poljšak
PJPolona Jamnik
Polona Jamnik
VKVito Kovač
Vito Kovač
GJGordana Čanadi Jurešić
Gordana Čanadi Jurešić
SSStjepan Spalj
Stjepan Spalj
The treatment with fixed orthodontic appliances could have an important role in the induction of oxidative stress and associated negative consequences. Because of the simultaneous effects of corrosion, deformation, friction, and mechanical stress on fixed orthodontic appliances during treatment, degradation of orthodontic brackets and archwires occurs, causing higher concentrations of metal ions in the oral cavity. Corroded appliances cause the release of metal ions, which may lead to the increased values of reactive oxygen species (ROS) due to metal-catalyzed free radical reactions. Chromium, iron, nickel, cobalt, titanium, and molybdenum all belong to the group of transition metals that can be subjected to redox reactions to form ROS. The estimation of health risk due to the amount of heavy metals released and the level of selected parameters of oxidative stress generated for the time of treatment with fixed orthodontic appliances is presented. Approaches to avoid oxidative stress and recommendations for the preventive use of topical or systemic antioxidants during orthodontic treatment are discussed.

24 October 2017 in Cranio®
Verified
Journal Article
Closed access
Simona TeccoSimona Tecco
Simona Tecco
Alessandro NotaAlessandro Nota
Alessandro Nota
Silvia CarusoSilvia Caruso
Silvia Caruso
JPJasmina Primožič
Jasmina Primožič
GMGiuseppe Marzo
Giuseppe Marzo
GEGherlone Felice Enrico
Gherlone Felice Enrico
Objective: This study investigated the prevalence of the signs and symptoms of temporomandibular disorders (TMD) among Italian adolescents. Methods: The data were recorded from 567 subjects (246 males and 321 females; age range 11-19 years), grouped according to age and molar class relationship. Results: Forty-four point one percent of subjects showed at least one sign or symptom of TMD, which were significantly more frequent in the 16-19 year-old group (52.9%) in respect to the 11-15 year-old group (39.8%) (chi(2 )= 8.78; p = 0.003). Signs and/or symptoms were about 1.6 times more frequent in subjects with Class II/1 malocclusion (chi(2)= 13.3,p = 0.0003), mostly for TMJ sounds (chi(2 )= 1.444; p = 0.036). Myalgia was more frequent in females than in males (chi(2) = 3.882; p = 0.049). Conclusion: TMD signs and/or symptoms among Italian adolescents seem diffused (44.1%). Therefore, all adolescents should be screened thorough medical history and clinical examination.

Verified
Journal Article
Open access
PDF file
VKVito Kovač
Vito Kovač
BPBorut Poljšak
Borut Poljšak
JPJasmina Primožič
Jasmina Primožič
PJPolona Jamnik
Polona Jamnik
Compositions of stainless steel, nickel-titanium, cobalt-chromium and β-titanium orthodontic alloys were simulated with mixtures of Fe, Ni, Cr, Co, Ti and Mo metal ions as potential oxidative stress-triggering agents. Wild-type yeast Saccharomyces cerevisiae and two mutants ΔSod1 and ΔCtt1 were used as model organisms to assess the cytotoxicity and oxidative stress occurrence. Metal mixtures at concentrations of 1, 10, 100 and 1000 µM were prepared out of metal chlorides and used to treat yeast cells for 24 h. Every simulated orthodontic alloy at 1000 µM was cytotoxic, and, in the case of cobalt-chromium alloy, even 100 µM was cytotoxic. Reactive oxygen species and oxidative damage were detected for stainless steel and both cobalt-chromium alloys at 1000 µM in wild-type yeast and 100 µM in the ΔSod1 and ΔCtt1 mutants. Simulated nickel-titanium and β-titanium alloy did not induce oxidative stress in any of the tested strains.

23 May 2019 in BioMed Research International
Verified
Journal Article
Open access
PDF file
VKVito Kovac
Vito Kovac
BPBorut Poljsak
Borut Poljsak
GPGiuseppe Perinetti
Giuseppe Perinetti
JPJasmina Primožič
Jasmina Primožič
The aim of the study was to assess the level of selected systemic oxidative stress parameters during the first week of orthodontic treatment with fixed appliances. Fifty-four males with malocclusion and having a similar lifestyle were randomized using a computer based procedure and allocated to either the treatment group (TG; n=27;24.6 ± 1.7 years) or control group (CG; n=27;24.7 ± 1.7 years). Capillary blood was collected at baseline and 6 hours, 24 hours, and 7 days after archwire insertion. At the same time points, capillary blood was retrieved in the CG. In order to determine the oxidative stress, both the reactive oxygen species (ROS) formation and the antioxidative defense (AD) potential were measured using the ROS testing and oxygen free radicals defense (equivalent to antioxidant defense) testing, respectively, by a blinded operator. The ratio between ROS and AD (ROS/AD) was calculated and data were analyzed using nonparametric tests. No drop-outs or harms were detected. At baseline, neither ROS (1.54 [1.22;2.12] and 1.74 [1.40;2.01] for the TG and CG, respectively), AD (1.19 [0.66;1.50] and 1.19 [0.57;1.42] for the TG and CG, respectively), nor ROS/AD levels were significantly different (p>0.05). After 24 hours, the ROS level significantly increased in the TG (2.05 [1.71;2.26]) and was higher compared to the CG ROS level (1.67 [1.29;1.95]; p=0.025), while for the AD level, no marked between and within group differences were detected. A notable change of ROS/AD ratio was observed over time only within the TG (p=0.026). Moreover, a significantly higher ROS/AD ratio was detected 24 hours after archwire insertion in the TG compared to the CG (2.69 [1.44;3.89] and 1.79 [1.45;2.35], respectively), followed by a decrease. Orthodontic treatment with fixed appliances might induce systemic oxidative stress in the short-term, since ROS levels and ROS/AD levels are normalized within 7 days after archwire insertion.

1 February 2022 in Coatings
Verified
Journal Article
Open access
PDF file
VKVito Kovač
Vito Kovač
BPBorut Poljšak
Borut Poljšak
MBMatic Bergant
Matic Bergant
JŠJanez Ščančar
Janez Ščančar
UMUros Mezeg
Uros Mezeg
JPJasmina Primožič
Jasmina Primožič
The aim was to assess the composition of released metal ions from fixed orthodontic appliances both in an in vitro and in vivo setting and to compare their quantities to evaluate any possible health risks associated with them. For the in vitro setting, a set of 24 as-received sterile SS brackets, 2 SS sterile archwires, and 2 NiTi sterile archwires were aged for 90 days in artificial saliva, and released metal ion concentrations were determined by inductively coupled plasma mass spectrometry (ICP-MS), using matrix-matched standards for calibration. For the in vivo setting, 15 brackets, 15 SS, and 15 NiTi archwires were retrieved after 90 days of intraoral exposure in 15 subjects. Debris composition on each part of the orthodontic appliance was assessed using scanning electron microscopy with energy dispersive spectroscopy (SEM/EDS). The present study evidenced a difference in the composition of released metal ions from fixed orthodontic appliances detected in an in vitro and in vivo setting. Generally, the relative content of metal ions was higher in the retrieved debris than that released in artificial saliva. The concentration of released metal ions from all tested alloys was below the upper recommended limit of daily intake; however, possible local effects in terms of hypersensitivity due to their accumulation in the debris cannot be excluded even with such concentrations.

20 November 2020 in European Journal of Orthodontics
Verified
Journal Article
Closed access
Vincenzo QuinziVincenzo Quinzi
Vincenzo Quinzi
Fabio Federici CanovaFabio Federici Canova
Fabio Federici Canova
FRFiorella Alessandra Rizzo
Fiorella Alessandra Rizzo
GMGiuseppe Marzo
Giuseppe Marzo
MRMarco Rosa
Marco Rosa
JPJasmina Primožič
Jasmina Primožič
Summary: Objectives: The aim was to identify factors associated with maxillary expander loss due to anchoring deciduous molars exfoliation and assess the diagnostic accuracy of the upper second premolar cusp position as a prognostic factor for the exfoliation of its corresponding deciduous molar. Materials/methods: Ninety-two subjects aged 8.4 ± 1.1 years, treated with a Haas or hyrax expander, and using the same expansion protocol and deciduous teeth as anchorage were included. The position of the upper second premolar cusp, according to the half pulp chamber (HPC) line of the ipsilateral upper first permanent molar, was assessed on pre-treatment panoramic radiographs. Results: A significant association between anchoring deciduous molar exfoliation and the position of the upper second premolar cusp according to the HPC line (P = 0.002; odds ratio = 5.7) was seen, while there was no association with gender, age, treatment duration, and type of expander. The median survival time for an anchoring deciduous molar, when the underlying premolar cusp was touching/crossing the HPC line, was 13.0 (11.7; 14.2) months. The upper second premolar cusp position to the HPC line showed high accuracy (at least 76.11 per cent) and substantial repeatability (at least 0.7) as a prognostic factor for the corresponding second deciduous molar exfoliation. Limitations: Applicability in the mixed dentition phase with fully erupted upper first permanent molars. Conclusions: The probability of a second deciduous molar to be successfully used as maxillary expander anchorage for at least 16 months is above 94 per cent; when at baseline, the corresponding premolar cusp is apical to the HPC line.