Alberto Domínguez-Vicent

Dr. Alberto Domínguez-Vicent


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Redox Biology
Verified
Journal Article
Open access
JTJames R. Tribble
James R. Tribble
AOAmin Otmani
Amin Otmani
SSShanshan Sun
Shanshan Sun
SESevannah A. Ellis
Sevannah A. Ellis
GCGloria Cimaglia
Gloria Cimaglia
PWPete Williams
Pete Williams
Nicotinamide adenine dinucleotide (NAD) is a REDOX cofactor and metabolite essential for neuronal survival. Glaucoma is a common neurodegenerative disease in which neuronal levels of NAD decline. We assess the effects of nicotinamide (a precursor to NAD) on retinal ganglion cells (the affected neuron in glaucoma) in normal physiological conditions and across a range of glaucoma relevant insults including mitochondrial stress and axon degenerative insults. We demonstrate retinal ganglion cell somal, axonal, and dendritic neuroprotection by nicotinamide in rodent models which represent isolated ocular hypertensive, axon degenerative, and mitochondrial degenerative insults. We performed metabolomics enriched for small molecular weight metabolites for the retina, optic nerve, and superior colliculus which demonstrates that ocular hypertension induces widespread metabolic disruption, including consistent changes to α-ketoglutaric acid, creatine/creatinine, homocysteine, and glycerophosphocholine. This metabolic disruption is prevented by nicotinamide. Nicotinamide provides further neuroprotective effects by increasing oxidative phosphorylation, buffering and preventing metabolic stress, and increasing mitochondrial size and motility whilst simultaneously dampening action potential firing frequency. These data support continued determination of the utility of long-term nicotinamide treatment as a neuroprotective therapy for human glaucoma.

29 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AVAbinaya Priya Venkataraman
Abinaya Priya Venkataraman
DSDelila Sirak
Delila Sirak
RBRune Brautaset
Rune Brautaset
ADAlberto Domínguez-Vicent
Alberto Domínguez-Vicent
Objective: To evaluate the performance of two subjective refraction measurement algorithms by comparing the refraction values, visual acuity, and the time taken by the algorithms with the standard subjective refraction (SSR). Methods: The SSR and two semi-automated algorithm-based subjective refraction (SR1 and SR2) in-built in the Vision-R 800 phoropter were performed in 68 subjects. In SR1 and SR2, the subject’s responses were recorded in the algorithm which continuously modified the spherical and cylindrical component accordingly. The main difference between SR1 and SR2 is the use of an initial fogging step in SR1. Results: The average difference and agreement limits intervals in the spherical equivalent between each refraction method were smaller than 0.25 D, and 2.00 D, respectively. For the cylindrical components, the average difference was almost zero and the agreement limits interval was less than 0.50 D. The visual acuities were not significantly different among the methods. The times taken for SR1 and SR2 were significantly shorter, and SR2 was on average was three times faster than SSR. Conclusions: The refraction values and the visual acuity obtained with the standard subjective refraction and algorithm-based methods were similar on average. The algorithm-based methods were significantly faster than the standard method.

23 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ADAlberto Domínguez-Vicent
Alberto Domínguez-Vicent
Loujain Al-SobohLoujain Al-Soboh
Loujain Al-Soboh
RBRune Brautaset
Rune Brautaset
AVAbinaya Priya Venkataraman
Abinaya Priya Venkataraman
Background: To evaluate the precision and accuracy of objective refraction measurement obtained with combinations of instrument design and technique. We also compared the performance of the instruments with subjective refraction measurements. Method and analysis: The objective refraction was measured in 71 subjects with three autorefractometers that have different designs and measurement principles (binocular with fogging, binocular without fogging, and monocular with fogging). Repeatability and reproducibility metrics were calculated for the objective refraction measurements. The agreement of the objective refraction measurements between the three instruments and the agreement with the subjective refraction measurements were evaluated. Results: All three autorefractometers had repeatability and reproducibility limits smaller than 0.70D. The smallest difference (0.10D) in the spherical equivalent was seen between the two binocular instruments. Compared with the subjective refraction, the binocular without fogging technique had the smallest mean difference in spherical equivalent (<0.20D) whereas the binocular fogging technique had the smallest limit of agreement interval (1.00D). For all comparisons, the mean difference and limit of agreement interval for the cylindrical components were lower than 0.10D and 0.75D, respectively. Conclusion: All three instruments evaluated had good repeatability and reproducibility. The binocular fogging technique provided the best agreement with subjective refraction.

22 August 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ADAlberto Domínguez-Vicent
Alberto Domínguez-Vicent
RBRune Brautaset
Rune Brautaset
AVAbinaya Priya Venkataraman
Abinaya Priya Venkataraman
To evaluate the repeatability of the new spectral domain optical coherence tomography (HOCT-1F), and also to evaluate the agreement between vertical and horizontal scan protocols. In addition, we also evaluated the relation between the repeatability and age. Three consecutive measurements of the inner limiting membrane–retinal pigment epithelium (ILM-RPE), inner limiting membrane–inner plexiform layer (ILM-IPL) from macular horizontal and vertical scans, and inner limiting membrane–retinal nerve fiber layer (ILM-RNFL) from optic disc horizontal scan. 159 subjects were included in the analysis. The within subject standard deviation (Sw) and the repeatability limits (Rlimit) are used to represent the repeatability of the parameters for the different sectors. The Sw for the ILM-RPE thickness was less than 3.5 μm for each sector and scan direction. The Sw values varied within the sectors and scan modes, with horizontal scan modes resulting in better values for the horizontal sectors, and vice versa. The Sw for the GCL-IPL thickness was less than 2 μm, and was similar between the vertical and horizontal scan modes for each sector map. For the optic disc scan, the Sw was not symmetric along the clock-hour map sectors, the largest Sw values were seen in the vertical sectors (8.6 μm). The mean difference between the vertical and horizontal scans was less than 2 μm for each retinal thickness sector map. Significant but weak correlation between the Sw and the subject’s age was seen in both macular and optic disc scans. The repeatability of the HOCT-1F to measure the ILM-RPE-, ILM-IPL- and ILM-RNFL-thickness is good. The repeatability of the ILM-RPE thickness is dependent on the scan direction, which should be taken into account when calculating retinal thickness. There is a weak correlation between the repeatability and the subject’s age.

2 June 2023 in Eye and Vision
Verified
Journal Article
Open access
PDF file
ADAlberto Domínguez-Vicent
Alberto Domínguez-Vicent
AVAbinaya Priya Venkataraman
Abinaya Priya Venkataraman
ADAmanda Dalin
Amanda Dalin
RBRune Brautaset
Rune Brautaset
RMRobert Montés-Micó
Robert Montés-Micó
Background: To evaluate the repeatability of a fully automated swept-source optical coherence tomography (SS-OCT) and its agreement with an optical low coherence reflectometry (OLCR) for several biometric parameters. Methods: In this study, 74 eyes of 74 patients were measured using the Eyestar 900 SS-OCT and Lenstar LS 900 OLCR. Flat keratometry (K1) and steep keratometry (K2), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were measured three times with each device. The repeatability was analyzed with the intrasubject standard deviation, coefficient of variability (CoV), and coefficient of repeatability (CoR) for each instrument. The agreement between the instruments was evaluated with Bland-Altman analysis. Results: K1, K2 and CCT CoV values were < 0.2%, < 0.4% and < 0.55%, respectively. Higher CoV values were found for ACD and LT ranging from 0.56% to 1.74%. The lowest CoV values were found for the AL measurements (0.03% and 0.06% for the Eyestar 900 and the Lenstar LS 900, respectively). AL measurements provided the highest repeatability, measured with both CoV and CoR values, and the CCT was the parameter with the lowest repeatability. The CCT and LT measurements were statistically significant between the two biometers (P < 0.001). The interval of the limits of agreement was < 0.6 D for K1 and K2, 15.78 µm for CCT, 0.21 mm for ACD, 0.34 mm for LT, and 0.08 mm for AL. Conclusions: Both biometers provide repeatable measurements for the different parameters analyzed and can be used interchangeably.

1 May 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
AVAbinaya Priya Venkataraman
Abinaya Priya Venkataraman
ADAlberto Domínguez-Vicent
Alberto Domínguez-Vicent
PSPaulina Bsc Selin
Paulina Bsc Selin
RBRune Brautaset
Rune Brautaset
Robert Montés-MicóRobert Montés-Micó
Robert Montés-Micó
Purpose: To evaluate the repeatability of a new swept source optical coherence tomography (SS-OCT)–based biometer to measure anterior segment parameters and to assess the agreement with 3 other imaging devices based on different measurement principles. Setting: Unit of Eye and Vision, Department of Clinical Neuroscience, Karolinska Institute, Stockholm, Sweden. Design: Prospective, comparative case series. Methods: 3 consecutive measurements were obtained in unoperated eyes with the Eyestar900 (SS-OCT), Lenstar 900, MS-39, and Sirius. The following anterior segment parameters were evaluated: central corneal thickness (CCT), corneal diameter (CD), aqueous depth (AQD), and corneal power metrics. The repeatability limit (Rlim), coefficient of variation (CoV), and a repeated measures Bland-Altman analysis were performed. Results: 74 eyes of 74 participants were measured. The Rlims for CCT, CD, and AQD were lower than 10 μm, 0.3 mm, and 0.10 mm for all devices, respectively. The corresponding CoVs for these parameters never exceeded 1.2%. The Rlim for the corneal power metrics never exceeded 0.60 diopter (D) for any of the instruments. Lenstar showed the best agreement with the MS-39 to measure CCT, CD, and AQD (limit of agreement interval, LoA: 15.54 μm, 0.55 mm, and 0.16 mm, respectively). The mean difference for keratometry parameters was lower than 0.3 D for all device comparisons, and the LoA interval ranged between 0.52 D and 1.21 D. Conclusions: The repeatability for measuring anterior segment parameters was good, and the agreement among all the instruments was good for CD and AQD measurements. However, for CCT and keratometer parameters, the instruments cannot be used interchangeably due to large LoA interval.